Romuald Jolivot

Romuald Jolivot

Auto-generated profile, based on publicly available information

Romuald Jolivot

BU-CROCCS, School of Engineering, Bangkok University, Pathumthani, Thailand

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2013
Verified
Conference Paper
Open access
PDF file
DNDorra Nouri
Dorra Nouri
YLYves Lucas
Yves Lucas
STSylvie Treuillet
Sylvie Treuillet
RJRomuald Jolivot
Romuald Jolivot
Franck MarzaniFranck Marzani
Franck Marzani
Accurate wound assessment is a critical task for patient care and health cost reduction at hospital but even still worse in the context of clinical studies in laboratory. This task, completely devoted to nurses, still relies on manual and tedious practices. Wound shape is measured with rules, tracing papers or rarely with alginate castings and serum injection. The wound tissues proportion is also estimated by a qualitative visual assessment based on the red-yellow-black code. Further to our preceding works on wound 3D complete assessment using a simple freehanded digital camera, we explore here the adaptation of this tool to wounds artificially created for experimentation purposes. It results that tissue uniformity and flatness leads to a simplified approach but requires multispectral imaging for enhanced wound delineation. We demonstrate that, in this context, a simple active contour method can successfully replace more complex tools such as SVM supervised classification, as no training step is required and that one shot is enough to deal with perspective projection errors. Moreover, involving all the spectral response of the tissue and not only RGB components provides a higher discrimination for separating healed epithelial tissue from granulation tissue. This research work is part of a comparative preclinical study on healing wounds. It aims to compare the efficiency of specific medical honeys with classical pharmaceuticals for wound care. Results revealed that medical honey competes with more expensive pharmaceuticals.

1 December 2020 in Optics & Laser Technology
Verified
Journal Article
Closed access
HDHironmay Deb
Hironmay Deb
NSNantarat Srisuai
Nantarat Srisuai
RJRomuald Jolivot
Romuald Jolivot
CPChamras Promptmas
Chamras Promptmas
Waleed S MohammadWaleed S Mohammad
Waleed S Mohammad
SBSakookan Boonruang
Sakookan Boonruang

1 June 2017
Verified
Conference Paper
Closed access
SASimran Agarwal
Simran Agarwal
RJRomuald Jolivot
Romuald Jolivot
Waleed S MohammadWaleed S Mohammad
Waleed S Mohammad
MKMichael Komodromos
Michael Komodromos
Laser beams shaped into flattop are widely used in various industrial and medical applications. There are various approaches to produce a flattop beam from a Gaussian beam. In this paper, a novel approach called Method of Projection is used to optimize a single element Radial phase mask to obtain flattop output beam. In this approach, Henkel transform and cross-correlation in iterative loop is used to optimize the parameters. Following this approach, a suitable phase mask pattern is obtained in grayscale. The simulated results are compared with target intensity profile through cross-correlation and further optimized to reach certain goodness value. The designed algorithm is a single element radially symmetric phase mask, which is low cost, alignment-free and robust. Hence, the proposed approach reduces the number of components required to develop a flattop output.