Objectives: The aim was to evaluate the role of resorbable membranes applied over customized titanium meshes related to soft tissue healing and bone regeneration after vertical/horizontal bone augmentation.Materials and Methods: Thirty patients with partial edentulism of the maxilla/mandible, with vertical/horizontal reabsorption of the alveolar bone, and needing implant‐supported restorations, were randomly divided into two groups: Group A was treated using only custom‐made meshes (Mesh‐) and Group B using custom‐made meshes with cross‐linked collagen membranes (Mesh+). Data collection included surgical/technical and healing complications, “pseudo‐periosteum” thickness, bone density, planned bone volume (PBV), regenerated bone volume (RBV), regeneration rate (RR), vertical bone gain (VBG), and implant survival in regenerated areas. Statistical analysis was performed between the two study groups using a significance level of α = .05.Results: Regarding the healing complications, the noninferiority analysis proved to be inconclusive, despite the better results of group Mesh+ (13%) compared to group Mesh‐ (33%): estimated value −1.13 CI‐95% from −0.44 to 0.17. Superiority approach confirmed the absence of significant differences (p = .39). RBV was 803.27 mm3 and 843.13 mm3, respectively, and higher RR was observed in group Mesh+ (82.3%) compared to Mesh‐ (74.3%), although this value did not reach a statistical significance (p = .44). All 30 patients completed the study, receiving 71 implants; 68 out of them were clinically stable and in function.Conclusion: The results showed that customized meshes alone do not appear to be inferior to customized meshes covered by cross‐linked collagen membranes in terms of healing complication rates and regeneration rates, although superior results were observed in group Mesh+compared to group Mesh‐ for all variables.
8 July 2019 in Clinical Implant Dentistry and Related Research
After guided bone regeneration (GBR) with different devices, a layer of connective tissue called pseudo-periosteum can be observed above the newly formed bone. The aim of this study is to evaluate the clinical and histologic features and to suggest a classification of this connective tissue after GBR with nonresorbable membranes or titanium (Ti)-mesh plus resorbable membranes. Forty patients with partial edentulism in the posterior mandible were randomized into two groups: 20 patients were treated by means of Ti-reinforced dense polytetrafluoroethylene (d-PTFE) membrane (group A), while the other 20 patients were treated with Ti-mesh and a cross-linked collagen membrane (group B). After 9 months and during re-opening surgery, bone density and pseudo-periosteum type were recorded. Pseudo-periosteum was classified into Type 1 (no tissue or tissue < 1 mm); Type 2 (regular tissue between 1 and 2 mm); and Type 3 (irregular tissue or tissue > 2 mm). Histologic analyses were performed to identify the features of pseudo-periosteum. Out of 40 patients, 36 (n = 19 in Group A; n = 17 in Group B) with 99 implants were analyzed after GBR and according to the study protocol. The vertical bone gain was 4.2 ± 1.0 mm in Group A and 4.1 ± 1.0 mm in Group B. Group A had a higher bone density and greater amounts of type 1 periosteum than Group B (P = .01 for both). The preliminary results of this study show that both d-PTFE membranes and Ti-mesh plus collagen membranes are two valid options for bone augmentation in the mandible. However, nonresorbable membranes achieve higher bone density and a thinner pseudo-periosteum layer above the newly formed bone.