Representative Publications

View All Publications
29 April 2014 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
RZRong Zeng
Rong Zeng
LXLie Xu
Lie Xu
LYLiangzhong Yao
Liangzhong Yao
BWBarry W. Williams
Barry W. Williams
This paper presents a hybrid modular multilevel converter (MMC), which combines full-bridge submodules (FBSM) and half-bridge submodules (HBSM). Compared with the FBSM-based MMC, the proposed topology has the same dc fault blocking capability but uses fewer power devices hence has lower power losses. To increase power transmission capability of the proposed hybrid MMC, negative voltage states of the FBSMs are adopted to extend the output voltage range. The optimal ratio of FBSMs and HBSMs, and the number of FBSMs generating a negative voltage state are calculated to ensure successful dc fault blocking and capacitor voltage balancing. Equivalent circuits of each arm consisting of two individual voltage sources are proposed and two-stage selecting and sorting algorithms for ensuring capacitor voltage balancing are developed. Comparative studies for different circuit configurations show excellent performance balance for the proposed hybrid MMC, when considering dc fault blocking capability, power losses, and device utilization. Experimental results during normal operation and dc fault conditions demonstrate feasibility and validity the proposed hybrid MMC.

24 September 2014 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
RZRong Zeng
Rong Zeng
LXLie Xu
Lie Xu
LYLiangzhong Yao
Liangzhong Yao
DMD. John Morrow
D. John Morrow
Compared to half-bridge-based modular multilevel converters (MMCs), full-bridge-based systems have the advantage of blocking the dc fault, but at the expense of increased power semiconductors and power losses. In view of the relationships among ac/dc voltages and currents in full-bridge-based MMC with the negative voltage state, this paper provides a detailed analysis on the link between capacitor voltage variation and the maximum modulation index. A hybrid MMC, consisting of mixed half-bridge and full-bridge circuits to combine their respective advantages is investigated in terms of its precharging process and transient dc fault ride-through capability. Simulation and experiment results demonstrate the feasibility and validity of the proposed strategy for a full-bridge-based MMC and the hybrid MMC.

2 June 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
RZRong Zeng
Rong Zeng
LXLie Xu
Lie Xu
LYLiangzhong Yao
Liangzhong Yao
SFStephen J. Finney
Stephen J. Finney
YWYi Wang
Yi Wang
This paper presents the control and operation of a hybrid HVDC system comprising a wind farm-side voltage-source converter rectifier and a grid-side LCC inverter for integrating wind power. The configuration and operation principle of the hybrid HVDC system are described. Commutation failure in the LCC inverter during an ac network disturbance is considered and its impact on the hybrid system operation is analyzed. An enhanced control strategy for the LCC inverter at the grid side and an alternative modular multilevel converter (MMC) topology using mixed half-bridge and full-bridge modules considered for the rectifier at the wind farm side are proposed. Simulation results using Matlab/Simulink are presented to demonstrate the robust performance during LCC inverter commutation failure to validate the operation and recovery of the hybrid system with the proposed control strategy and MMC configuration.

13 May 2016 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JHJiabing Hu
Jiabing Hu
KXKecheng Xu
Kecheng Xu
LLLei Lin
Lei Lin
RZRong Zeng
Rong Zeng
This paper presents an enhanced control for HVDC systems employing hybrid modular multilevel converters (MMCs) during asymmetrical dc voltage faults. The characteristics of pole-to-ground (PTG) fault under different system grounding schemes are analyzed. Then, the principle of enhanced control strategy to deal with the PTG fault is presented for a hybrid-MMC-based HVDC system with symmetrical monopolar configuration. A new control variable is proposed on the arm voltages to distribute the power transmitted from the ac side between the upper and lower arms. By adopting the enhanced control, the overvoltage and the fault current can be eliminated when a PTG fault occurs. Furthermore, the hybrid-MMC-based HVDC system can operate continuously with adjustable active power and controllable reactive power by controlling the upper and lower arms of the converter asymmetrically during a fault period. Finally, the feasibility of the proposed control scheme is verified by simulation results in PSCAD/EMTDC.

24 August 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MLMaozeng Lu
Maozeng Lu
JHJiabing Hu
Jiabing Hu
RZRong Zeng
Rong Zeng
WLWuhua Li
Wuhua Li
LLLei Lin
Lei Lin
Due to different charging and discharging characteristics of full-bridge submodules and half-bridge submodules in hybrid modular multilevel converters (MMC), capacitor voltage imbalance will occur under boosted ac voltage or reduced dc voltage conditions. To address this issue, the mechanism of capacitor voltage imbalance is carefully studied, with three main factors-modulation index, power angle, and hybridization ratio-summarized and their effect on capacitor voltage imbalance analyzed. Further, a control strategy based on fundamental frequency reactive circulating current injection is proposed to keep the capacitor voltage balanced in the hybrid MMC. The amplitude and phase angle of the injected circulating current are calculated and their influence on the energy fluctuation in the submodules' capacitors and the semiconductors' current stress is explored. Experimental results under boosted ac voltage and reduced dc voltage conditions demonstrate the feasibility and validity of the proposed scheme.

22 December 2015 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YHYihua Hu
Yihua Hu
RZRong Zeng
Rong Zeng
WCWenping Cao
Wenping Cao
JZJiangfeng Zhang
Jiangfeng Zhang
SFStephen J. Finney
Stephen J. Finney
High-power and high-voltage gain dc-dc converters are key to high-voltage direct current (HVDC) power transmission for offshore wind power. This paper presents an isolated ultra-high step-up dc-dc converter in matrix transformer configuration. A flyback-forward converter is adopted as the power cell and the secondary side matrix connection is introduced to increase the power level and to improve fault tolerance. Because of the modular structure of the converter, the stress on the switching devices is decreased and so is the transformer size. The proposed topology can be operated in column interleaved modes, row interleaved modes, and hybrid working modes in order to deal with the varying energy from the wind farm. Furthermore, fault-tolerant operation is also realized in several fault scenarios. A 400-W dc-dc converter with four cells is developed and experimentally tested to validate the proposed technique, which can be applied to high-power high-voltage dc power transmission.