11 April 2023 in IEEE Transactions on Biomedical Engineering
Flexible ultrasound transducers (FUTs), capable of conforming to irregular surfaces, have become a research hotspot in the field of medical imaging. With these transducers, high-quality ultrasound images can be obtained only if strict design criteria are fulfilled. Moreover, the relative positions of array elements must be determined, which are important for ultrasound beamforming and image reconstruction. These two major characteristics present great challenges to the design and fabrication of FUTs compared to that for traditional rigid probes. In this study, an optical shape-sensing fiber was embedded into a 128-element flexible linear array transducer to acquire the real-time relative positions of array elements to produce high-quality ultrasound images. Minimum concave and convex bend diameters of approximately 20 and 25 mm, respectively, were achieved. The transducer was flexed 2000 times, and yet no obvious damage was observed. Stable electrical and acoustic responses confirmed its mechanical integrity. The developed FUT exhibited an average center frequency of 6.35 MHz, and average −6-dB bandwidth of 69.2%. The array profile and element positions measured by the optic shape-sensing system were instantly transferred to the imaging system. Phantom experiments for both spatial resolution and contrast-to-noise ratio proved that FUTs can maintain satisfactory imaging capability despite bending to sophisticated geometries. Finally, color Doppler images and Doppler spectra of the peripheral arteries of healthy volunteers were obtained in real time.
2 November 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Structural abnormalities and functional changes of renal microvascular networks play a significant pathophysiologic role in the occurrence of kidney diseases. Super-resolution ultrasound imaging has been successfully utilized to visualize the microvascular network and provide valuable diagnostic information. To prevent the burst of microbubbles, a lower mechanical index (MI) is generally used in ultrasound localization microscopy (ULM) imaging. However, high noise levels lead to incorrect signal localizations in relatively low-MI settings and deep tissue. In this study, we implemented a block-matching 3-D (BM3D) image-denoising method, after the application of singular value decomposition filtering, to further suppress the noise at various depths. The in vitro flow-phantom results show that the BM3D method helps the significant reduction of the error localizations, thus improving the localization accuracy. In vivo rhesus macaque experiments help conclude that the BM3D method improves the resolution more than other image-based denoising techniques, such as the nonlocal means method. The obtained clutter-filtered images with fewer incorrect localizations can enable robust ULM imaging, thus helping in establishing an effective diagnostic tool.
25 January 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
High-frequency convex array transducer, featuring both high spatial resolution and wide field of view, has been successfully developed for ophthalmic imaging. To further expand its application range to small animals’ imaging, this work develops a high-frequency microconvex array transducer possessing smaller aperture size and wider scanning angle. This transducer featured 128 array elements arranged in a curvilinear 2–2 piezoelectric composite configuration, yielding a maximum view angle of 97.8°. The array was composed of two front matching layers, a nonconductive backing layer, and a customized flexible circuit that electrically connected array elements to coaxial cables. The center frequency and the −6-dB fractional bandwidth were about 18.14 MHz and 69.15%, respectively. The image of a tungsten wire phantom resulted in approximately 62.9- $ {\mu } \text{m}$ axial resolution and 121.3- $ {\mu }\text{m}$ lateral resolution. The image of the whole kidney of a rat as well as its internal arteries was acquired in vivo , demonstrating the imaging capability of the proposed high-frequency microconvex array transducers for small animals’ imaging applications.
27 April 2022 in IEEE Transactions on Biomedical Engineering
Objective: The morphological and hemodynamic characterization of the microvascular network around the gastrointestinal (GI) tract can be of significant clinical value for the early diagnosis and treatment of GI tract cancer. Ultrasound localization microscopy (ULM) imaging has been demonstrated to be capable of resolving the microvascular network. However, the endoscopic application of ULM imaging techniques is still unknown. In this study, an endoscopic ultrasound localization microscopy (e-ULM) imaging technique was developed to evaluate the changes of microvasculature during GI tract tumor growth. Methods: A customized circular array transducer (center frequency: 6.8 MHz) and the coherent diverging wave compounding method were used to generate B-mode images. Spatiotemporal singular value decomposition processing was used to eliminate the background signals before signal localizations. The centroids of spatially isolated signals were localized and summed to generate the final super-resolution image. Results: The final microvasculature map of a rabbit GI tract tumor reveals that e-ULM can be used to surpass the diffraction limit in traditional endoscopic ultrasound (EUS) imaging. Furthermore, it is observed that data from different stages of tumor growth exhibit significant differences in microvascular pattern and density. Conclusion: Our study demonstrated the implementation and application of an in vivo e-ULM imaging technique for the evaluation of the microvasculature of GI tumors. Significance: The efficient e-ULM imaging technique shows potential for use in the detection of GI tract tumor microcirculation changes and subsequent diagnosis of GI tract cancer.
21 October 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Atherosclerotic cardiovascular disease is a major cause of human disability and mortality. Our previous study demonstrated the safety and efficacy of sonodynamic therapy (SDT) on atherosclerotic plaques. However, traditional single-element therapeutic transducer has single acoustic field, and positioning therapeutic and imaging transducers in the same position is difficult during ultrasound imaging-guided SDT. Continuously changing the position of transducers to intervene lesions in different positions is required, increasing the difficulty of treatment. Thus, SDT device with precise theranostics is required. Therefore, we designed and fabricated a ’concentric ultrasound transducer for theranostics’ (CUST-T), comprising a central 8 MHz linear array transducer for ultrasound imaging, and a peripheral 1 MHz hollow two-dimensional planar array transducer for generating phased-array focused ultrasound (PAFUS). The CUST-T exhibited high imaging resolution at a distance of up to 20 mm from the transducer and could generate personalized complex PAFUS acoustic field to match various lesions. In vitro biomedical results showed that, PAFUS-SDT induced RAW264.7-derived foam cell apoptosis leading to a targeting field apoptotic rate 4.36 to 6.24-times that of the non-targeting field and the significant apoptotic region was consistent with PAFUS acoustic field. In vivo , PAFUS-SDT guided by ultrasound imaging significantly increased the lumen area (P < 0.05) and collagen level (P < 0.01), whereas the wall thickness (P < 0.05) and lipid content (P < 0.01) of rabbit femoral artery were reduced. In conclusion, CUST-T provided image guidance sufficient for accurate SDT for atherosclerotic plaques in peripheral arteries and could be applied in clinical practice.