Hitoshi Asakawa

Hitoshi Asakawa

Auto-generated profile, based on publicly available information

Hitoshi Asakawa

Graduate School of Natural Science and Technology Kanazawa University Kanazawa Ishikawa Japan

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2010 in Physical Review Letters
Verified
Journal Article
Open access
TFTakeshi Fukuma
Takeshi Fukuma
YUYasumasa Ueda
Yasumasa Ueda
SYShunsuke Yoshioka
Shunsuke Yoshioka
HAHitoshi Asakawa
Hitoshi Asakawa
We have developed a method referred to as three-dimensional scanning force microscopy (3D-SFM) which enables us to visualize water distribution at a solid-liquid interface with an atomic-scale resolution in less than 1~min. The 3D-SFM image obtained at a mica-water interface visualizes 3D distributions of adsorbed water molecules above the center of hexagonal cavities and the laterally distributed hydration layer. The atomically resolved 3D-SFM image showing mirror symmetry suggests the existence of surface relaxation of the cleaved mica surface next to the aqueous environment.

12 December 2012 in Nanoscale
Verified
Journal Article
Closed access
PDF file
EHElena T. Herruzo
Elena T. Herruzo
HAHitoshi Asakawa
Hitoshi Asakawa
TFTakeshi Fukuma
Takeshi Fukuma
Ricardo Garcia GarciaRicardo Garcia Garcia
Ricardo Garcia Garcia
We develop a bimodal force microscopy method to map the three-dimensional force fields and their time-evolution on a variety of solid–water interfaces. The force maps show an oscillatory decaying force perpendicular to the solid surface with a 0.3 nm periodicity. The technique enables the three-dimensional imaging and mapping of the hydration layers and forces on mica and protein GroEL surfaces with 10 piconewton, 2 angstrom and 40 second (whole volume) resolutions. We record the existence and evolution of nanoscale perturbations involving thousands of water molecules of the protein–liquid interface. Those instabilities are not found in stiff and atomically flat interfaces.

25 September 2012 in ACS Nano
Verified
Journal Article
Open access
HAHitoshi Asakawa
Hitoshi Asakawa
SYShunsuke Yoshioka
Shunsuke Yoshioka
KNKen-Ichi Nishimura
Ken-Ichi Nishimura
TFTakeshi Fukuma
Takeshi Fukuma
At biological interfaces, flexible surface structures and mobile water interact with each other to present non-uniform three-dimensional (3D) distributions. In spite of their impact on biological functions, molecular-scale understanding of such phenomena has remained elusive. Here we show direct visualization of such interfacial structures with subnanometer-scale resolution by 3D scanning force microscopy (3D-SFM). We measured a 3D force distribution at an interface between a model biological membrane and buffer solution by scanning a sharp tip within the 3D interfacial space. We found that vertical cross sections of the 3D image taken along a specific lateral direction show characteristic molecular-scale contrasts tilted at 30° to the membrane surface. Detailed analysis of the 3D image reveals that the tilted contrast corresponds to the time-averaged conformation of fluctuating lipid headgroups. On the basis of the obtained results, we discuss the relationships among the hydration structure, headgroup fluctuation, molecular fluidity, and mechanical strength of the membrane. The results demonstrate that 3D-SFM is capable of visualizing averaged 3D distribution of fluctuating surface structures as well as that of mobile water (i.e., hydration structure) at interfaces between biological systems and water.

16 March 2012 in Nanotechnology
Verified
Journal Article
Open access
TFT Fukuma
T Fukuma
KOK Onishi
K Onishi
NKN Kobayashi
N Kobayashi
Atsushi MatsukiAtsushi Matsuki
Atsushi Matsuki
HAH Asakawa
H Asakawa
In this study, we have investigated the performance of liquid-environment FM-AFM with various cantilevers having different dimensions from theoretical and experimental aspects. The results show that reduction of the cantilever dimensions provides improvement in the minimum detectable force as long as the tip height is sufficiently long compared with the width of the cantilever. However, we also found two important issues to be overcome to achieve this theoretically expected performance. The stable photothermal excitation of a small cantilever requires much higher pointing stability of the exciting laser beam than that for a long cantilever. We present a way to satisfy this stringent requirement using a temperature controlled laser diode module and a polarization-maintaining optical fiber. Another issue is associated with the tip. While a small carbon tip formed by electron beam deposition (EBD) is desirable for small cantilevers, we found that an EBD tip is not suitable for atomic-scale applications due to the weak tip-sample interaction. Here we show that the tip-sample interaction can be greatly enhanced by coating the tip with Si. With these improvements, we demonstrate atomic-resolution imaging of mica in liquid using a small cantilever with a megahertz-order resonance frequency. In addition, we experimentally demonstrate the improvement in the minimum detectable force obtained by the small cantilever in measurements of oscillatory hydration forces.

1 December 2010 in Review of Scientific Instruments
Verified
Journal Article
Closed access
NKNaritaka Kobayashi
Naritaka Kobayashi
HAHitoshi Asakawa
Hitoshi Asakawa
TFTakeshi Fukuma
Takeshi Fukuma
We have developed a method for local potential measurements in liquid using frequency modulation atomic force microscopy. In this method, local potential is calculated from the first and second harmonic vibrations of a cantilever induced by applying an ac bias voltage between a tip and a sample. The use of an ac bias voltage with a relatively high frequency prevents uncontrolled electrochemical reactions and redistribution of ions and water. The nanoscale resolution of the method is demonstrated by imaging potential distribution of a dodecylamine thin film deposited on a graphite surface in 1 mM NaCl solution.

20 October 2014 in Nanotechnology
Verified
Journal Article
Open access
SAS M R Akrami
S M R Akrami
HNH Nakayachi
H Nakayachi
TWT Watanabe-Nakayama
T Watanabe-Nakayama
HAH Asakawa
H Asakawa
TFT Fukuma
T Fukuma
Recent advancement of dynamic-mode atomic force microscopy (AFM) for liquid-environment applications enabled atomic-scale studies on various interfacial phenomena. However, instabilities and poor reproducibility of the measurements often prevent systematic studies. To solve this problem, we have investigated the effect of various tip treatment methods for atomic-scale imaging and force measurements in liquid. The tested methods include Si coating, Ar plasma, Ar sputtering and UV/O₃ cleaning. We found that all the methods provide significant improvements in both the imaging and force measurements in spite of the tip transfer through the air. Among the methods, we found that the Si coating provides the best stability and reproducibility in the measurements. To understand the origin of the fouling resistance of the cleaned tip surface and the difference between the cleaning methods, we have investigated the tip surface properties by x-ray photoelectron spectroscopy and contact angle measurements. The results show that the contaminations adsorbed on the tip during the tip transfer through the air should desorb from the surface when it is immersed in aqueous solution due to the enhanced hydrophilicity by the tip treatments. The tip surface prepared by the Si coating is oxidized when it is immersed in aqueous solution. This creates local spots where stable hydration structures are formed. For the other methods, there is no active mechanism to create such local hydration sites. Thus, the hydration structure formed under the tip apex is not necessarily stable. These results reveal the desirable tip properties for atomic-scale AFM measurements in liquid, which should serve as a guideline for further improvements of the tip treatment methods.