Dimitrios G. Mikropoulos

Dimitrios G. Mikropoulos

Auto-generated profile, based on publicly available information

Dimitrios G. Mikropoulos


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Journal of Glaucoma
Verified
Journal Article
Closed access
MSMarco Sales-Sanz
Marco Sales-Sanz
EAEsther Arranz-Marquez
Esther Arranz-Marquez
David P PiñeroDavid P Piñero
David P Piñero
CSCarolina Arruabarrena Sánchez
Carolina Arruabarrena Sánchez
DMDimitrios G. Mikropoulos
Dimitrios G. Mikropoulos
MTMiguel Teus
Miguel Teus
To assess the effect of laser in situ keratomileusis (LASIK) on ocular rigidity and compare its effect on intraocular pressure (IOP) readings with Goldmann applanation tonometry (GAT), Schiøtz indentation tonometry (ST), and dynamic contour tonometry (DCT). Prospective, observational, single-masked study. Eighty-one patients who underwent myopic LASIK and 108 unoperated myopic control patients were included in the study. The IOP was measured using GAT, DCT, and ST. The coefficient of ocular rigidity (Ko) was obtained from the regression analysis of the 3 readings obtained with each weight of the ST. Linear multiple regression analysis was performed with dummy variables to assess the effects of age, central corneal thickness (CCT), and refractive surgery on measured IOP values. Age, CCT, and previous LASIK explained 39.41% of the IOP readings with GAT, 25.31% with DCT, and 3.28% with ST. LASIK caused a mean decrease of -2.51 mm Hg in IOP readings (P=0.000) with GAT, -1.29 mm Hg (P=0.036) with DCT, and no significant change in IOP readings with ST (P=0.299). Significant differences in the Ko were observed between the LASIK and control groups. The Ko values were unrelated to age and CCT in the LASIK and control groups. ST seems to be less affected by previous LASIK procedures. There is a difference in the ocular rigidity between the unoperated and LASIK eyes that is not correlated with the CCT. Therefore, ST seems to measure changes in the biomechanical behavior of corneas that underwent LASIK surgery.

27 July 2026 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
RBRodanthi Christina Bartzoulianou
Rodanthi Christina Bartzoulianou
ACAnne L. Coleman
Anne L. Coleman
MWM. Roy Wilson
M. Roy Wilson
AHAlon Harris
Alon Harris
DGDimitrios A. Giannoulis
Dimitrios A. Giannoulis
FTFotis Topouzis
Fotis Topouzis