Zachary D. Harms

Zachary D. Harms

Auto-generated profile, based on publicly available information

Zachary D. Harms

Department of Chemistry and ‡Department of Molecular and Cellular Biochemistry, Indiana University , Bloomington, Indiana 47405, United States

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2010 in ACS Nano
Verified
Journal Article
Closed access
JPJohn M. Perry
John M. Perry
KZKaimeng Zhou
Kaimeng Zhou
ZHZachary D. Harms
Zachary D. Harms
SJStephen C. Jacobson
Stephen C. Jacobson

11 November 2011 in Analytical Chemistry
Verified
Journal Article
Closed access
ZHZachary D. Harms
Zachary D. Harms
KMKlaus B. Mogensen
Klaus B. Mogensen
PNPedro S. Nunes
Pedro S. Nunes
KZKaimeng Zhou
Kaimeng Zhou
BHBrett W. Hildenbrand
Brett W. Hildenbrand
SJStephen C. Jacobson
Stephen C. Jacobson

20 October 2014 in Analytical Chemistry
Verified
Journal Article
Open access
DHDaniel G. Haywood
Daniel G. Haywood
ZHZachary D. Harms
Zachary D. Harms
SJStephen C. Jacobson
Stephen C. Jacobson
We report the measurement of electroosmotic mobilities in nanofluidic channels with rectangular cross sections and compare our results with theory. Nanofluidic channels were milled directly into borosilicate glass between two closely spaced microchannels with a focused ion beam instrument, and the nanochannels had half-depths (h) of 27, 54, and 108 nm and the same half-width of 265 nm. We measured electroosmotic mobilities in NaCl solutions from 0.1 to 500 mM that have Debye lengths (κ–1) from 30 to 0.4 nm, respectively. The experimental electroosmotic mobilities compare quantitatively to mobilities calculated from a nonlinear solution of the Poisson–Boltzmann equation for channels with a parallel-plate geometry. For the calculations, ζ-potentials measured in a microchannel with a half-depth of 2.5 μm are used and range from −6 to −73 mV for 500 to 0.1 mM NaCl, respectively. For κh > 50, the Smoluchowski equation accurately predicts electroosmotic mobilities in the nanochannels. However, for κh < 10, the electrical double layer extends into the nanochannels, and due to confinement within the channels, the average electroosmotic mobilities decrease. At κh ≈ 4, the electroosmotic mobilities in the 27, 54, and 108 nm channels exhibit maxima, and at 0.1 mM NaCl, the electroosmotic mobility in the 27 nm channel (κh = 1) is 5-fold lower than the electroosmotic mobility in the 2.5 μm channel (κh = 100).

17 June 2021 in Organic Process Research & Development
Verified
Journal Article
Closed access
MFMichael O. Frederick
Michael O. Frederick
RBRaymond A. Boyse
Raymond A. Boyse
TBTimothy M. Braden
Timothy M. Braden
JCJoel R. Calvin
Joel R. Calvin
BCBradley M. Campbell
Bradley M. Campbell
HXHan Xia
Han Xia

9 December 2014 in Analytical Chemistry
Verified
Journal Article
Open access
ZHZachary D. Harms
Zachary D. Harms
DHDaniel G. Haywood
Daniel G. Haywood
AKAndrew R. Kneller
Andrew R. Kneller
LSLisa Selzer
Lisa Selzer
AZAdam Zlotnick
Adam Zlotnick
SJStephen C. Jacobson
Stephen C. Jacobson
Electrophoretic mobilities and particle sizes of individual Hepatitis B Virus (HBV) capsids were measured in nanofluidic channels with two nanopores in series. The channels and pores had three-dimensional topography and were milled directly in glass substrates with a focused ion beam instrument assisted by an electron flood gun. The nanochannel between the two pores was 300 nm wide, 100 nm deep, and 2.5 μm long, and the nanopores at each end had dimensions 45 nm wide, 45 nm deep, and 400 nm long. With resistive-pulse sensing, the nanopores fully resolved pulse amplitude distributions of T = 3 HBV capsids (32 nm outer diameter) and T = 4 HBV capsids (35 nm outer diameter) and had sufficient peak capacity to discriminate intermediate species from the T = 3 and T = 4 capsid distributions in an assembly reaction. Because the T = 3 and T = 4 capsids have a wiffle-ball geometry with a hollow core, the observed change in current due to the capsid transiting the nanopore is proportional to the volume of electrolyte displaced by the volume of capsid protein, not the volume of the entire capsid. Both the signal-to-noise ratio of the pulse amplitude and resolution between the T = 3 and T = 4 distributions of the pulse amplitudes increase as the electric field strength is increased. At low field strengths, transport of the larger T = 4 capsid through the nanopores is hindered relative to the smaller T = 3 capsid due to interaction with the pores, but at sufficiently high field strengths, the T = 3 and T = 4 capsids had the same electrophoretic mobilities (7.4 × 10–5 cm2 V–1 s–1) in the nanopores and in the nanochannel with the larger cross-sectional area.

26 August 2015 in ACS Nano
Verified
Journal Article
Closed access
ZHZachary D. Harms
Zachary D. Harms
LSLisa Selzer
Lisa Selzer
AZAdam Zlotnick
Adam Zlotnick
SJStephen C. Jacobson
Stephen C. Jacobson