Aurora Rosvoll Groendahl

Aurora Rosvoll Groendahl

Auto-generated profile, based on publicly available information

Aurora Rosvoll Groendahl

Norwegian University of Life Sciences

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
AGAurora Rosvoll Groendahl
Aurora Rosvoll Groendahl
IKIngerid Skjei Knudtsen
Ingerid Skjei Knudtsen
BHBao Ngoc Huynh
Bao Ngoc Huynh
MMMartine Mulstad
Martine Mulstad
YMYngve Mardal Mardal Moe
Yngve Mardal Mardal Moe
CFCecilia Marie Futsæther
Cecilia Marie Futsæther
Target volume delineation is a vital but time-consuming and challenging part of radiotherapy, where the goal is to deliver sufficient dose to the target while reducing risks of side effects. For head and neck cancer (HNC) this is complicated by the complex anatomy of the head and neck region and the proximity of target volumes to organs at risk. The purpose of this study was to compare and evaluate conventional PET thresholding methods, six classical machine learning algorithms and a 2D U-Net convolutional neural network (CNN) for automatic gross tumor volume (GTV) segmentation of HNC in PET/CT images. For the latter two approaches the impact of single versus multimodality input on segmentation quality was also assessed. 197 patients were included in the study. The cohort was split into training and test sets (157 and 40 patients, respectively). Five-fold cross-validation was used on the training set for model comparison and selection. Manual GTV delineations represented the ground truth. Tresholding, classical machine learning and CNN segmentation models were ranked separately according to the cross-validation Sørensen–Dice similarity coefficient (Dice). PET thresholding gave a maximum mean Dice of 0.62, whereas classical machine learning resulted in maximum mean Dice scores of 0.24 (CT) and 0.66 (PET; PET/CT). CNN models obtained maximum mean Dice scores of 0.66 (CT), 0.68 (PET) and 0.74 (PET/CT). The difference in cross-validation Dice between multimodality PET/CT and single modality CNN models was significant (p ≤ 0.0001). The top-ranked PET/CT-based CNN model outperformed the best-performing thresholding and classical machine learning models, giving significantly better segmentations in terms of cross-validation and test set Dice, true positive rate, positive predictive value and surface distance-based metrics (p ≤ 0.0001). Thus, deep learning based on multimodality PET/CT input resulted in superior target coverage and less inclusion of surrounding normal tissue.

9 February 2021 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
YMYngve Mardal Moe
Yngve Mardal Moe
AGAurora Rosvoll Groendahl
Aurora Rosvoll Groendahl
OTOliver Tomic
Oliver Tomic
EDEinar Dale
Einar Dale
EMEirik Malinen
Eirik Malinen
CFCecilia Marie Futsæther
Cecilia Marie Futsæther
Purpose: Identification and delineation of the gross tumour and malignant nodal volume (GTV) in medical images are vital in radiotherapy. We assessed the applicability of convolutional neural networks (CNNs) for fully automatic delineation of the GTV from FDG-PET/CT images of patients with head and neck cancer (HNC). CNN models were compared to manual GTV delineations made by experienced specialists. New structure-based performance metrics were introduced to enable in-depth assessment of auto-delineation of multiple malignant structures in individual patients. Methods: U-Net CNN models were trained and evaluated on images and manual GTV delineations from 197 HNC patients. The dataset was split into training, validation and test cohorts (n= 142, n = 15 and n = 40, respectively). The Dice score, surface distance metrics and the new structure-based metrics were used for model evaluation. Additionally, auto-delineations were manually assessed by an oncologist for 15 randomly selected patients in the test cohort. Results: The mean Dice scores of the auto-delineations were 55%, 69% and 71% for the CT-based, PET-based and PET/CT-based CNN models, respectively. The PET signal was essential for delineating all structures. Models based on PET/CT images identified 86% of the true GTV structures, whereas models built solely on CT images identified only 55% of the true structures. The oncologist reported very high-quality auto-delineations for 14 out of the 15 randomly selected patients. Conclusions: CNNs provided high-quality auto-delineations for HNC using multimodality PET/CT. The introduced structure-wise evaluation metrics provided valuable information on CNN model strengths and weaknesses for multi-structure auto-delineation.

17 December 2021 in Acta Oncologica
Verified
Journal Article
Closed access
FKFranziska Knuth
Franziska Knuth
IAIngvild Askim Adde
Ingvild Askim Adde
BHBao Ngoc Huynh
Bao Ngoc Huynh
AGAurora Rosvoll Groendahl
Aurora Rosvoll Groendahl
RWRené Mario Winter
René Mario Winter
CFCecilia Marie Futsæther
Cecilia Marie Futsæther
Tumor delineation is time- and labor-intensive and prone to inter- and intraobserver variations. Magnetic resonance imaging (MRI) provides good soft tissue contrast, and functional MRI captures tis...

10 August 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
BHBao Ngoc Huynh
Bao Ngoc Huynh
AGAurora Rosvoll Groendahl
Aurora Rosvoll Groendahl
OTOliver Tomic
Oliver Tomic
KLKristian Hovde Hovde Liland
Kristian Hovde Hovde Liland
IKIngerid Skjei Knudtsen
Ingerid Skjei Knudtsen
CFCecilia Marie Futsæther
Cecilia Marie Futsæther
Objective. Target volumes for radiotherapy are usually contoured manually, which can be time-consuming and prone to inter- and intra-observer variability. Automatic contouring by convolutional neural networks (CNN) can be fast and consistent but may produce unrealistic contours or miss relevant structures. We evaluate approaches for increasing the quality and assessing the uncertainty of CNN-generated contours of head and neck cancers with PET/CT as input. Approach. Two patient cohorts with head and neck squamous cell carcinoma and baseline 18F-fluorodeoxyglucose positron emission tomography and computed tomography images (FDG-PET/CT) were collected retrospectively from two centers. The union of manual contours of the gross primary tumor and involved nodes was used to train CNN models for generating automatic contours. The impact of image preprocessing, image augmentation, transfer learning and CNN complexity, architecture, and dimension (2D or 3D) on model performance and generalizability across centers was evaluated. A Monte Carlo dropout technique was used to quantify and visualize the uncertainty of the automatic contours. Main results. CNN models provided contours with good overlap with the manually contoured ground truth (median Dice Similarity Coefficient: 0.75–0.77), consistent with reported inter-observer variations and previous auto-contouring studies. Image augmentation and model dimension, rather than model complexity, architecture, or advanced image preprocessing, had the largest impact on model performance and cross-center generalizability. Transfer learning on a limited number of patients from a separate center increased model generalizability without decreasing model performance on the original training cohort. High model uncertainty was associated with false positive and false negative voxels as well as low Dice coefficients. Significance. High quality automatic contours can be obtained using deep learning architectures that are not overly complex. Uncertainty estimation of the predicted contours shows potential for highlighting regions of the contour requiring manual revision or flagging segmentations requiring manual inspection and intervention.

16 November 2021 in Acta Oncologica
Verified
Journal Article
Closed access
AGAurora Rosvoll Groendahl
Aurora Rosvoll Groendahl
YMYngve Mardal Moe
Yngve Mardal Moe
CKChristine Kiran Kaushal
Christine Kiran Kaushal
BHBao Ngoc Huynh
Bao Ngoc Huynh
EREspen Rusten
Espen Rusten
CFCecilia Marie Futsæther
Cecilia Marie Futsæther
Accurate target volume delineation is a prerequisite for high-precision radiotherapy. However, manual delineation is resource-demanding and prone to interobserver variation. An automatic delineatio...

13 March 2022
Verified
Book Chapter
Closed access
PDF file
JRJintao Ren
Jintao Ren
BHBao-Ngoc Huynh
Bao-Ngoc Huynh
AGAurora Rosvoll Groendahl
Aurora Rosvoll Groendahl
OTOliver Tomic
Oliver Tomic
CFCecilia Marie Futsæther
Cecilia Marie Futsæther
SKStine Sofia Korreman
Stine Sofia Korreman