23 December 2010 in Journal of Biomechanical Engineering
The aim of this investigation was to achieve the first step toward a comprehensive model of the lymphatic system. A numerical model has been constructed of a lymphatic vessel, consisting of a short series chain of contractile segments (lymphangions) and of intersegmental valves. The changing diameter of a segment governs the difference between the flows through inlet and outlet valves and is itself governed by a balance between transmural pressure and passive and active wall properties. The compliance of segments is maximal at intermediate diameters and decreases when the segments are subject to greatly positive or negative transmural pressure. Fluid flow is the result of time-varying active contraction causing diameter to reduce and is limited by segmental viscous and valvular resistance. The valves effect a smooth transition from low forward-flow resistance to high backflow resistance. Contraction occurs sequentially in successive lymphangions in the forward-flow direction. The behavior of chains of one to five lymphangions was investigated by means of pump function curves, with variation of valve opening parameters, maximum contractility, lymphangion size gradation, number of lymphangions, and phase delay between adjacent lymphangion contractions. The model was reasonably robust numerically, with mean flow-rate generally reducing as adverse pressure was increased. Sequential contraction was found to be much more efficient than synchronized contraction. At the highest adverse pressures, pumping failed by one of two mechanisms, depending on parameter settings: either mean leakback flow exceeded forward pumping or contraction failed to open the lymphangion outlet valve. Maximum pressure and maximum flow-rate were both sensitive to the contractile state; maximum pressure was also determined by the number of lymphangions in series. Maximum flow-rate was highly sensitive to the transmural pressure experienced by the most upstream lymphangions, suggesting that many feeding lymphatics would be needed to supply one downstream lymphangion chain pumping at optimal transmural pressure.
1 January 2005 in Journal of Computational Physics
1 July 1984 in IMA Journal of Applied Mathematics
A straightforward numerical algorithm for simulating the propagation of a wavefield in a two-dimensional randomly varying medium is described. Both a finite-difference and a fast Fourier transform method are described. These methods are well known, but there is a novel treatment of the random scattering term in the wave equation that allows accurate answers to be economically obtained. The methods are then tested by comparison with known approximate solutions for the fourth moment of a propagating wavefield. The two approaches show good agreement, thus confirming the usefulness of the analytic results and at the same time indicating that the simulation process should be a powerful tool for investigating the higher-order statistics of the field. The agreement should hold in situations encountered in optical and acoustic scattering experiments.
26 June 2013 in Biomechanics and Modeling in Mechanobiology
25 August 2008 in Physical Review Letters
We present a scaling theory for unforced inviscid two-dimensional turbulence. Our model unifies existing spatial and temporal scaling theories. The theory is based on a self-similar distribution of vortices of different sizes . Our model uniquely determines the spatial and temporal scaling of the associated vortex number density which allows the determination of the energy spectra and the vortex distributions. We find that the vortex number density scales as , which implies an energy spectrum , significantly steeper than the classical Batchelor-Kraichnan scaling. High-resolution numerical simulations corroborate the model.
6 February 2013 in Computer Methods in Biomechanics and Biomedical Engineering
An existing lumped-parameter model of multiple lymphangions (lymphatic vascular segments) in series is adapted for the incorporation of recent physiological measurements of lymphatic vascular properties. The new data show very marked nonlinearity of the passive pressure–diameter relation during distension, relative to comparable blood vessels, and complex valve behaviour. Since lymph is transported as a result of either the active contraction or the passive squeezing of vascular segments situated between two one-way valves, the performance of these valves is of primary importance. The valves display hysteresis (the opening and closing pressure drop thresholds differ), a bias to staying open (both state changes occur when the trans-valve pressure drop is adverse) and pressure-drop threshold dependence on transmural pressure. These properties, in combination with the strong nonlinearity that valve operation represents, have in turn caused intriguing numerical problems in the model, and we describe numerical stratagems by which we have overcome the problems. The principal problem is also generalised into a relatively simple mathematical example, for which solution detail is provided using two different solvers.