Alexander Viktorovich Pavlovsky

Alexander Viktorovich Pavlovsky

Auto-generated profile, based on publicly available information

Alexander Viktorovich Pavlovsky

National Research Tomsk Polytechnic University, Tomsk, Russia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2022 in Drug development & registration
Verified
Journal Article
Open access
PDF file
KGKonstantin Alexandrovich Gusev
Konstantin Alexandrovich Gusev
DMD. N. Maimistov
D. N. Maimistov
ВПВ. И. Павловский
В. И. Павловский
AAA. R. Aliev
A. R. Aliev
АПА. В. Павловский
А. В. Павловский
EFE. V. Flisyuk
E. V. Flisyuk
Introduction. The solubility of an active pharmaceutical ingredient plays a major role in drug absorption. Hot melt extrusion is a batch or continuous process that allows creating solid dispersion systems based on various carriers in order to increase solubility and bioavailability of active substances. Development of effective and safe analgesics is one of the most vital tasks of organic and medicinal chemistry. An innovative non-opioid analgesic with very low toxicity and low dosage, but practically insoluble in water, was used in this work. It was suggested to obtain a solid dispersion by hot melt extrusion in order to increase bioavailability.Aim. Development a hot melt extrusion technology for production of a solid dispersion system of PAV-0056 as an active substance and Plasdone™ S-630 as a polymeric carrier to increase the solubility.Materials and methods. PAV-0056 (methyl-2-(7-nitro-2-oxo-5-phenyl-3-propoxy-2,3-dihydro-1H-benzo[e][1,4]diazepin-1-yl)acetate) (JSC "Organica", Russia) Figure 1; Plasdone™ S-630 (Boai NKY Pharmaceuticals Ltd., China); PEG-1500 (Clariant, Switzerland); acetonitrile for chromatography (Thermo Fisher Scientific, Germany). Extrudates were obtained using a HAAKE™ MiniCTW co-rotating twin-screw laboratory extruder (Thermo Fisher Scientific, Germany). Extrudates were examined by optical microscopy and differential scanning calorimetry, and time of water solution stability was determined. The quantitative content of the active substance and related impurities in the 2.5 % solid dispersion of PAV-0056 was determined by HPLC-UV.Results and discussion. Hot melt extrusion process conditions were established for a mixture of 2.5 % PAV-0056 and Plasdone™ S-630. Stability of the extrudate solution in water was studied, the content of the active substance and impurities in the extrudates was determined. Based on the binary mixture, a composition containing 10 % of PEG-1500 was developed. The optimal conditions for the extrusion process were chosen for obtaining a solid dispersion system that meets the requirements of the regulatory documentation for the content of the active substance and impurities.Conclusion. The binary mixture proved to be unsuccessful for the creation of SDS by hot melt extrusion due to significant accumulation of impurities during the extrusion process. By adding PEG-1500 to the composition, it was possible to considerably lower the operating temperature of the process, reduce the impurity content in the extrudate, and maintain satisfactory stability of the PAV-0056 solution in water.

1 January 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
APAlexander Viktorovich Pavlovsky
Alexander Viktorovich Pavlovsky
AFAlexander Alexandrovich Filipas
Alexander Alexandrovich Filipas
VSVladislav Olegovich Sorokozherdiev
Vladislav Olegovich Sorokozherdiev
This paper devotes to the actualization and analysis of various methods of monitoring the human respiratory system. Since this system can subject to various disturbances (environment) and diseases (COPD, pneumonia, asthma, COVID 19), it raises the question of quality diagnostics. This review considers non-invasive methods of respiratory monitoring that use the following sensors: piezoresistive, inductive, piezoelectric, impedance, accelerometer, gyroscope, acoustic, thermistor, temperature, pressure, humidity, ECG, PPG. The last two sensors produce cardiovascular diagnoses, but with certain methods it is possible to extract the respiratory component. In addition, the devices (pneumotachograph and spirometer), which are references for the diagnosis of the respiratory system, are considered. As a result of this study, the following were considered: sensors and devices were reviewed with examples of their use; direct measurements were highlighted; and the analysis of each sensor considered showed that, with proper setup and calibration, an acceptably comparable result to reference devices can achieve.