Relevance. The use of distributed fiber-optic temperature sensors in oil production wells can improve the quality of data obtained during operation. Aim. To show that the captured temperature distribution contains random fluctuations, the magnitude of which is comparable to the magnitude of thermoanomalies caused by the filtration flow of oil in the reservoir. Methods. To reduce the noise of the original signal taken from a real oil well, various approximation methods: median smoothing, moving average, exponential smoothing, Fourier filtering, decision tree, random forest, adaptive boosting and Nadaraya–Watson kernel regression method, were analyzed. Results and conclusions. The authors analyzed the results of application of these types of signal post-processing in terms of the following parameters: accuracy of approximation of equilibrium geothermal distribution in the well sump, where analytical determination of temperature distribution is possible, smoothness of the approximating function, uniqueness of the solution and demandingness of computational resources. It is shown that the application of adaptive boosting and Fourier filtering for this problem gives the largest approximation errors. Median smoothing, exponential smoothing and random forest give similar results in accuracy and low computational costs. The first does not have smoothness of solution. The second one depends to a large extent on the tuning parameters and the obtained solution may be either noisy as well, or the smooth solution may exhibit systematic error caused by random deviations of the initial points. Such error can be compensated by additional averaging at the initial stages of exponential smoothing. The random forest approximation is also tuning dependent, and regions of overfitting where the approximation replicates the original signal may be adjacent to a very coarse approximation of the original signal; this always produces a new approximation at each generation. The best results were obtained by the Nadaraya–Watson kernel regression method, since the solution found has the lowest error, high smoothness and uniqueness, in contrast to machine learning methods. On the basis of analyzing the features of the algorithm of this method, as well as the machine representation of real numbers, we propose methods to improve the computational efficiency of the Nadaraya–Watson kernel regression. For citation: Nikulin I.L., Mishurinskikh S.V., Chudinov P.Yu., Semenov A.S., Melekhin A.A., Nikulina D.I. Approximation and noise reduction in oil well thermometry by distributed fiber optic sensors. Bulletin of the Tomsk Polytechnic University. Geo Assets Engineering, 2026, vol. 337, no. 8, pp. 77–89. http://doi.org/10.18799/24131830/2026/8/5054