Patrick W. Hales

Patrick W. Hales

Auto-generated profile, based on publicly available information

Patrick W. Hales

Developmental Imaging and Biophysics Section, Institute of Child Health, University College London, London, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2015 in NMR in Biomedicine
Verified
Journal Article
Open access
Matthew Grech-SollarsMatthew Grech-Sollars
Matthew Grech-Sollars
PHPatrick W. Hales
Patrick W. Hales
KMKeiko Miyazaki
Keiko Miyazaki
FRFelix Raschke
Felix Raschke
DRDaniel Rodriguez
Daniel Rodriguez
CCChris A. Clark
Chris A. Clark
The purpose of this work was to assess the reproducibility of diffusion imaging, and in particular the apparent diffusion coefficient (ADC), intra-voxel incoherent motion (IVIM) parameters and diffusion tensor imaging (DTI) parameters, across multiple centres using clinically available protocols with limited harmonization between sequences. An ice-water phantom and nine healthy volunteers were scanned across fives centres on eight scanners (four Siemens 1.5T, four Philips 3T). The mean ADC, IVIM parameters (diffusion coefficient D and perfusion fraction f) and DTI parameters (mean diffusivity MD and fractional anisotropy FA), were measured in grey matter, white matter and specific brain sub-regions. A mixed effect model was used to measure the intra- and inter-scanner coefficient of variation (CV) for each of the five parameters. ADC, D, MD and FA had a good intra- and inter-scanner reproducibility in both grey and white matter, with a CV ranging between 1% and 7.4%; mean 2.6%. Other brain regions also showed high levels of reproducibility except for small structures such as the choroid plexus. The IVIM parameter f had a higher intra-scanner CV of 8.4% and inter-scanner CV of 24.8%. No major difference in the inter-scanner CV for ADC, D, MD and FA was observed when analysing the 1.5T and 3T scanners separately. ADC, D, MD and FA all showed good intra-scanner reproducibility, with the inter-scanner reproducibility being comparable or faring slightly worse, suggesting that using data from multiple scanners does not have an adverse effect compared with using data from the same scanner. The IVIM parameter f had a poorer inter-scanner CV when scanners of different field strengths were combined, and the parameter was also affected by the scan acquisition resolution. This study shows that the majority of diffusion MRI derived parameters are robust across 1.5T and 3T scanners and suitable for use in multi-centre clinical studies and trials.

13 June 2009 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
GPGernot Plank
Gernot Plank
RBRebecca A.B. Burton
Rebecca A.B. Burton
PHPatrick Hales
Patrick Hales
MBMartin Bishop
Martin Bishop
TMTahir Mansoori
Tahir Mansoori
PKPeter Kohl
Peter Kohl
This paper presents methods to build histo-anatomically detailed individualized cardiac models. The models are based on high-resolution three-dimensional anatomical and/or diffusion tensor magnetic resonance images, combined with serial histological sectioning data, and are used to investigate individualized cardiac function. The current state of the art is reviewed, and its limitations are discussed. We assess the challenges associated with the generation of histo-anatomically representative individualizedin silicomodels of the heart. The entire processing pipeline including image acquisition, image processing, mesh generation, model set-up and execution of computer simulations, and the underlying methods are described. The multifaceted challenges associated with these goals are highlighted, suitable solutions are proposed, and an important application of developed high-resolution structure–function models in elucidating the effect of individual structural heterogeneity upon wavefront dynamics is demonstrated.

1 October 2012 in Progress in Biophysics and Molecular Biology
Verified
Journal Article
Open access
PHPatrick W. Hales
Patrick W. Hales
JSJürgen E. Schneider
Jürgen E. Schneider
RBRebecca A.B. Burton
Rebecca A.B. Burton
BWBenjamin J. Wright
Benjamin J. Wright
CBChristian Bollensdorff
Christian Bollensdorff
PKPeter Kohl
Peter Kohl
Deformation and wall-thickening of ventricular myocardium are essential for cardiac pump function. However, insight into the histo-anatomical basis for cardiac tissue re-arrangement during contraction is limited. In this report, we describe dynamic changes in regionally prevailing cardiomyocyte (fibre) and myolaminar (sheet) orientations, using Diffusion Tensor Imaging (DTI) of ventricles in the same living heart in two different mechanical states. Hearts, isolated from Sprague-Dawley rats, were Langendorff-perfused and imaged, initially in their slack state during cardioplegic arrest, then during lithium-induced contracture. Regional fibre- and sheet-orientations were derived from DTI-data on a voxel-wise basis. Contraction was accompanied with a decrease in left-handed helical fibres (handedness relative to the baso-apical direction) in basal, equatorial, and apical sub-epicardium (by 14.0%, 17.3%, 15.8% respectively; p < 0.001), and an increase in right-handed helical fibres of the sub-endocardium (by 11.0%, 12.1% and 16.1%, respectively; p < 0.001). Two predominant sheet-populations were observed, with sheet-angles of either positive (β+) or negative (β-) polarity relative to a 'chamber-horizontal plane' (defined as normal to the left ventricular long-axis). In contracture, mean 'intersection'-angle (geometrically quantifiable intersection of sheet-angle projections) between β+ and β- sheet-populations increased from 86.2 ± 5.5° (slack) to 108.3 ± 5.4° (p < 0.001). Subsequent high-resolution DTI of fixed myocardium, and histological sectioning, reconfirmed the existence of alternating sheet-plane populations. Our results suggest that myocardial tissue layers in alternating sheet-populations align into a more chamber-horizontal orientation during contraction. This re-arrangement occurs via an accordion-like mechanism that, combined with inter-sheet slippage, can significantly contribute to ventricular deformation, including wall-thickening in a predominantly centripetal direction and baso-apical shortening.

5 February 2014 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Open access
PHPatrick W Hales
Patrick W Hales
JKJamie M Kawadler
Jamie M Kawadler
SASarah E Aylett
Sarah E Aylett
FKFenella Kirkham
Fenella Kirkham
CCChristopher A Clark
Christopher A Clark
The human brain changes structurally and functionally during adolescence, with associated alterations in cerebral perfusion. We performed dynamic arterial spin labeling (ASL) magnetic resonance imaging in healthy subjects between 8 and 32 years of age, to investigate changes in cerebral hemodynamics during normal development. In addition, an inversion recovery sequence allowed quantification of changes in longitudinal relaxation time ( T1) and equilibrium longitudinal magnetization ( M0). We present mean and reference ranges for normal values of T1, M0, cerebral blood flow (CBF), bolus arrival time, and bolus duration in cortical gray matter, to provide a tool for identifying age-matched perfusion abnormalities in this age range in clinical studies. Cerebral blood flow and T1 relaxation times were negatively correlated with age, without gender or hemisphere differences. The same was true for M0 anteriorly, but posteriorly, males but not females showed a significant decline in M0 with increasing age. Two examples of the clinical utility of these data in identifying age-matched perfusion abnormalities, in Sturge–Weber syndrome and sickle cell anemia, are illustrated.

6 March 2014 in European Radiology
Verified
Journal Article
Closed access
PDF file
MCMarica Cutajar
Marica Cutajar
DTDavid L. Thomas
David L. Thomas
PHPatrick W. Hales
Patrick W. Hales
TBT. Banks
T. Banks
CCChristopher A. Clark
Christopher A. Clark
IGIsky Gordon
Isky Gordon

30 September 2015 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Open access
PHPatrick W Hales
Patrick W Hales
FKFenella Kirkham
Fenella Kirkham
CCChristopher A Clark
Christopher A Clark
Many MRI techniques require prior knowledge of the T1-relaxation time of blood ( T1 bl). An assumed/fixed value is often used; however, T1 bl is sensitive to magnetic field ( B0), haematocrit ( Hct), and oxygen saturation ( Y). We aimed to combine data from previous in vitro measurements into a mathematical model, to estimate T1 bl as a function of B0, Hct, and Y. The model was shown to predict T1 bl from in vivo studies with a good accuracy (±87 ms). This model allows for improved estimation of T1 bl between 1.5–7.0 T while accounting for variations in Hct and Y, leading to improved accuracy of MRI-derived perfusion measurements.