Kevin S. Zhang

Kevin S. Zhang

Auto-generated profile, based on publicly available information

Kevin S. Zhang

Stanford University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
RPRajorshi Paul
Rajorshi Paul
KZKevin S. Zhang
Kevin S. Zhang
MJMyra Kurosu Jalil
Myra Kurosu Jalil
NCNicolas Castaño
Nicolas Castaño
SKSungu Kim
Sungu Kim
STSindy Tang
Sindy Tang
The hydrodynamic cell splitter splits single-cell ciliateStentor coeruleususing a microfluidic cross junction at a high throughput of 500 cells min−1. Fragment viability decreases with increasing hydrodynamic stress and decreasing fragment size.

19 February 2019 in Physical Review E
Verified
Journal Article
Open access
PDF file
LPLuigi Perotti
Luigi Perotti
KZKevin Zhang
Kevin Zhang
JRJoseph Rudnick
Joseph Rudnick
RBRobijn F. Bruinsma
Robijn F. Bruinsma
In this work we extend the Caspar-Klug construction to the archaeal viruses, which in recent years have captured the attention of many researchers for their ability to thrive in extreme environments. We assume that the shells of archaeal viruses are composed of hexamers and pentamers—as is true for icosahedral viruses—together with heptamers, necessary to introduce negative Gauss curvature. Following the original work of Caspar and Klug, we first construct models capable of reproducing the shape observed in electron microscopy images of archaeal viruses. Next, using the technique of kirigami, we present a systematic way to formulate archaeal virus templates from regular hexagonal lattices. Finally, we utilize the presented techniques to build finite element models of archaeal virus geometries and investigate their shapes as a function of material properties. In particular, using thin-shell elasticity theory, we describe a buckling transition as a function of a modified Föppl–von Kármán number γ★ and we show how changes in γ★ may initiate the tail formation in the Acidianus two-tailed archaeal virus.

17 June 2019 in Developmental Medicine & Child Neurology
Verified
Journal Article
Open access
PDF file
JZJoanne Zhou
Joanne Zhou
KZKevin Zhang
Kevin Zhang
KCKatelyn Cahill‐Rowley
Katelyn Cahill‐Rowley
ELEvan Lowe
Evan Lowe
JRJessica Rose
Jessica Rose
Aim: To develop an easily‐administered metric to quantify gait impairment in children and to assess its use in children with cerebral palsy (CP).Method: The Pediatric Temporal‐spatial Deviation Index (TDI) was developed from gait data collected from 75 typically developing children (37 males, 38 females; mean age 9y 4mo; interquartile range [IQR] 8–10y) and 17 children diagnosed with spastic CP (nine males, eight females; mean age 9y 9mo; IQR 9–11y), in Gross Motor Function Classification System (GMFCS) levels I to III, aged 7 to 11 years. Children walked on a pressure‐sensitive mat. Children with CP also completed 3D gait analysis. The Kaiser‐Meyer‐Olkin test of sampling adequacy was used for temporal‐spatial feature selection. Principal components obtained from temporal‐spatial gait parameters quantified deviation from typically developing gait. Deviation was normalized to a Pediatric TDI score mean (standard deviation [SD]) of 100 (10). The Pediatric TDI for children with CP was compared to 3D motion capture‐based Gait Deviation Index (GDI).Results: The Pediatric TDI was significantly lower for children with CP compared to typically developing children (p<0.001), correlated with average GDI (r=0.610, p=0.009), and demonstrated sensitivity (0.78) and specificity (0.88) to gait function, assessed with GDI.Interpretation: The Pediatric TDI is an easily administered, revealing gait metric that can be used in children with CP in pediatric clinics and for research. Detection of gait abnormalities in the clinic can expedite diagnosis and treatment.What this paper adds: The Pediatric Temporal‐spatial Deviation Index (TDI) is a single‐score index of gait deviation, based on nine parameters. The Pediatric TDI was more revealing than single temporal‐spatial gait parameters. The Pediatric TDI is quick and simple to administer in the clinic.

2 October 2025 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
ZLZhengda Li
Zhengda Li
KZKevin S. Zhang
Kevin S. Zhang
YCYuping Chen
Yuping Chen
STSindy Tang
Sindy Tang
JFJames E. Ferrell
James E. Ferrell
Trigger waves, self-regenerating fronts of biochemical activity that spread without losing speed or amplitude, are widespread in cell signaling. Apoptosis is one example of a process that propagates through the cytoplasm via trigger waves. Curiously, in some contexts, like synaptic pruning, apoptotic caspase activation is confined to specific subcellular regions. We hypothesized that at junctions between a thin cytoplasmic extension, like a dendritic spine, and a thicker one, like a dendrite, trigger wave propagation may be blocked even though diffusion is not, as a result of the general properties of trigger waves and bistable systems. This hypothesis was explored theoretically through modeling studies and dimensional arguments, which confirmed that trigger wave compartmentalization was possible and that the critical channel width required for compartmentalization was likely to be biologically relevant. These predictions were then tested experimentally with undiluted Xenopus egg extracts that were induced to undergo apoptosis. We found that channels that are less than a few microns in diameter are small enough to compartmentalize apoptosis, and that the critical width is inversely proportional to trigger wave speed. Thus, cellular projections and tubules can allow for the compartmentalization of biochemical states within a spatially continuous cytoplasm, a fundamental yet previously overlooked mechanism for controlling biochemical signaling and cellular functions.

8 February 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
KZKevin S. Zhang
Kevin S. Zhang
RRRamon Rodriguez
Ramon Rodriguez
STSindy Tang
Sindy Tang
Ciliates are powerful unicellular model organisms that have been used to elucidate fundamental biological processes. However, the high motility of ciliates presents a major challenge in studies using live-cell microscopy and microsurgery. While various immobilization methods have been developed, they are physiologically disruptive to the cell and incompatible with microscopy and/or microsurgery. Here, we describe a Simple Microfluidic Operating Room for the Examination and Surgery of Stentor coeruleus (SMORES). SMORES uses Quake valve-based microfluidics to trap, compress, and perform surgery on Stentor as our model ciliate. Compared with previous methods, immobilization by physical compression in SMORES is more effective and uniform. The mean velocity of compressed cells is 24 times less than that of uncompressed cells. The compression is minimally disruptive to the cell and is easily applied or removed using a 3D-printed pressure rig. We demonstrate cell immobilization for up to 2 hours without sacrificing cell viability. SMORES is compatible with confocal microscopy and is capable of media exchange for pharmacokinetic studies. Finally, the modular design of SMORES allows laser ablation or mechanical dissection of a cell into many cell fragments at once. These capabilities are expected to enable biological studies previously impossible in ciliates and other motile species.

10 June 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
RPRajorshi Paul
Rajorshi Paul
KZKevin S. Zhang
Kevin S. Zhang
MJMyra Kurosu Jalil
Myra Kurosu Jalil
NCNicolas Castaño
Nicolas Castaño
SKSungu Kim
Sungu Kim
STSindy Tang
Sindy Tang
Stentor coeruleus , a single-cell ciliated protozoan, is a model organism for wound healing and regeneration studies. Despite Stentor ’s large size (up to 2 mm in extended state), microdissection of Stentor remains challenging. In this work, we describe a hydrodynamic cell splitter, consisting of a cross junction, capable of splitting Stentor cells in a non-contact manner at a high throughput of ∼500 cells/min under continuous operation. Introduction of asymmetry in the flow field at the cross junction leads to asymmetric splitting of the cells to generate cell fragments as small as ∼8.5 times the original cell size. Characterization of cell fragment viability shows reduced 5-day survival as fragment size decreases and as the extent of hydrodynamic stress imposed on the fragments increases. Our results suggest that cell fragment size and composition, as well as mechanical stress, play important roles in the long-term repair of Stentor cells and warrant further investigations. Nevertheless, the hydrodynamic splitter can be useful for studying phenomena immediately after cell splitting, such as the closure of wounds in the plasma membrane which occurs on the order of 100 – 1000 seconds in Stentor .