A fractional flow reserve (FFR) value ≥0.90 after percutaneous coronary intervention (PCI) is associated with a reduced risk of adverse cardiovascular events. TARGET-FFR is an investigator-initiated, single-centre, randomized controlled trial to determine the feasibility and efficacy of a post-PCI FFR-guided optimization strategy vs. standard coronary angiography in achieving final post-PCI FFR values ≥0.90. After angiographically guided PCI, patients were randomized 1:1 to receive a physiology-guided incremental optimization strategy (PIOS) or a blinded coronary physiology assessment (control group). The primary outcome was the proportion of patients with a final post-PCI FFR ≥0.90. Final FFR ≤0.80 was a prioritized secondary outcome. A total of 260 patients were randomized (131 to PIOS, 129 to control) and 68.1% of patients had an initial post-PCI FFR <0.90. In the PIOS group, 30.5% underwent further intervention (stent post-dilation and/or additional stenting). There was no significant difference in the primary endpoint of the proportion of patients with final post-PCI FFR ≥0.90 between groups (PIOS minus control 10%, 95% confidence interval −1.84 to 21.91, P = 0.099). The proportion of patients with a final FFR ≤0.80 was significantly reduced when compared with the angiography-guided control group (−11.2%, 95% confidence interval −21.87 to −0.35], P = 0.045). Over two-thirds of patients had a physiologically suboptimal result after angiography-guided PCI. An FFR-guided optimization strategy did not significantly increase the proportion of patients with a final FFR ≥0.90, but did reduce the proportion of patients with a final FFR ≤0.80. Findings of initial post-percutaneous coronary intervention fractional flow reserve and pullback assessments. (A) Post-percutaneous coronary intervention fractional flow reserve results following standard-of-care stenting [*238/260 (92%) with core lab-adjudicated post-percutaneous coronary intervention fractional flow reserve results available for analysis]. (B) Summary findings of 259 initial post-percutaneous coronary intervention fractional flow reserve pullback assessments (pre-randomization) demonstrating the patterns of residual disease in the study vessels. Protocol-defined targets for additional optimization measure in red bars. Multiple findings may have co-existed within individual vessels. Focal lesion defined as an abrupt pressure drop ≥0.05 fractional flow reserve units on pullback. (C) Primary endpoint—Proportion of patients with final post-percutaneous coronary intervention fractional flow reserve value ≥0.90. (D) Secondary endpoint—Proportion of patients with final post-percutaneous coronary intervention fractional flow reserve ≤0.80. Diffuse Distal, diffuse pressure gradient distal to stented segment; Diffuse Proximal, diffuse pressure gradient proximal to stented segment; Focal Distal, focal pressure drop distal to stented segment; Focal Proximal, Focal pressure drop proximal to stented segment; FFR, fractional flow reserve; HTG, hyperaemic trans-stent gradient; PCI, percutaneous coronary intervention.
1 April 2021 in Journal of Interventional Cardiology
Background. While thinner struts are associated with improved clinical outcomes in bare-metal stents (BMS), reducing strut thickness may affect drug delivery from drug-eluting stents (DES) and there are limited data comparing otherwise similar thin and thick strut DES. We assessed 2-year outcomes of patients treated with a thin strut (84–88um) cobalt-chromium, biodegradable polymer, Biolimus A9-eluting stent (CoCr-BP-BES) and compared these to patients treated with a stainless steel, biodegradable polymer, Biolimus A9-eluting stent (SS-BP-BES). Methods. In total, 1257 patients were studied: 400 patients from 12 centres receiving ≥1 CoCr-BP-BES in the prospective Biomatrix Alpha registry underwent prespecified comparison with 857 patients who received ≥1 Biomatrix Flex SS-BP-BES in the LEADERS study (historical control). The primary outcome was major adverse cardiac events (MACE)—cardiac death, myocardial infarction (MI), or clinically driven target vessel revascularization (cd-TVR). Propensity analysis was used to adjust for differences in baseline variables and a landmark analysis at day-3 to account for differences in periprocedural MI definitions. Results. MACE at 2 years occurred in 6.65% CoCr-BP-BES versus 13.23% SS-BP-BES groups (unadjusted HR 0.48 [0.31–0.73]; ). Following propensity analysis, 2-year adjusted MACE rates were 7.4% versus 13.3% (HR 0.53 [0.35–0.79]; ). Definite or probable stent thrombosis, adjudicated using identical criteria in both studies, occurred less frequently with CoCr-BP-BES (1.12% vs. 3.22%; adjusted HR 0.32 [0.11–0.9]; ). In day-3 landmark analysis, the difference in 2-year MACE was no longer significant but there was a lower patient-orientated composite endpoint (11.7% vs. 18.4%; HR 0.6 [0.43–0.83]; ) and a trend to lower target vessel failure (5.8% vs. 9.1%; HR 0.63 [0.4–1.00]; ). Conclusion. At 2-year follow-up, propensity-adjusted analysis showed the thin strut (84–88um) Biomatrix Alpha CoCr-BP-BES was associated with improved clinical outcomes compared with the thicker strut (114–120um) Biomatrix Flex SS-BP-BES.
Chronic total occlusion (CTO) remains the most complex anatomical subset of lesions in percutaneous coronary intervention (PCI), often requiring advanced techniques and technologies, including the use of microcatheters. The BIOMICS study is a premarket first-in-human prospective, multicenter, open-label, single-arm trial investigating the safety and efficacy of a novel coronary microcatheter (BioMC, Biosensors International) in 100 patients with symptoms of ischemia undergoing elective CTO-PCI. The primary efficacy end point of the study was device success defined according to the CTO-ARC (Chronic Total Occlusion Academic Research Consortium) criteria namely the ability of the microcatheter to successfully facilitate placement of a guide wire beyond the occluded coronary segment. The primary safety end point was the incidence of in-hospital cardiac death or myocardial infarction at hospital discharge. Hundred patients were recruited between March 2022 and January 2023. The primary efficacy end point was achieved in 75% of patients (95% CI, 65.3%-83.1%; P < .0001 for superiority compared to the prespecified performance goal of 54%). The primary safety end point of in-hospital cardiac death or myocardial infarction was observed in 2% of the patients. There were no study device-related coronary perforations or device failures. The use of a novel coronary microcatheter during CTO-PCI was associated with a high device success and an excellent safety profile.
8 February 2021 in Catheterization and Cardiovascular Interventions
Introduction: The impact of a vascular complication (VC) in the setting of intraaortic balloon pump (IABP) supported PCI on clinical outcomes is unclear.Methods: Using data from the BCIS National PCI Database, multivariate logistic regression was used to identify independent predictors of a VC. Propensity scoring was used to quantify the association between a VC and outcomes.Results: Between 2007 and 2014, 9,970 PCIs in England and Wales were supported by IABP (1.6% of total PCI), with 224 femoral VCs (2.3%). Annualized rates of a VC reduced as the use of radial access for PCI increased. The independent predictors of a VC included a procedural complication (odds ratio [OR] 2.9,p < .001), female sex (OR 2.3,p < .001), PCI for stable angina (OR 3.47,p = .028), and use of a glycoprotein inhibitor (OR 1.46 [1.1:2.5],p = .04), with a lower likelihood of a VC when radial access was used for PCI (OR 0.48,p = .008). A VC was associated with a higher likelihood of transfusion (OR 5.7 [3.5:9.2],p < .0001), acute kidney injury (OR 2.6 [1.2:6.1],p = .027), and periprocedural MI (OR 3.2 [1.5:6.7],p = .002) but not with adjusted mortality at discharge (OR 1.2 [0.8:1.7],p = .394) or 12‐months (OR 1.1 [0.76:1.56],p = .639). In sensitivity analyses, there was a trend towards higher mortality in patients experiencing a VC who underwent PCI for stable angina (OR 4.1 [1.0:16.4],pvalue for interaction .069).Discussion and ConclusionsAlthough in‐hospital morbidity was observed to be adversely affected by occurrence of a VC during IABP‐supported PCI, in‐hospital and 1‐year survival were similar between groups.