8 April 2021 in IEEE Access
Aiming at the problems of transient over-current and over-voltage in the switching process of AC/DC hybrid microgrid in grid-connected mode and island mode, which leads to the sudden change of transmission power and seriously affects the power transmission quality. In this paper, an improved seamless switching control strategy of droop control with disturbance observer is designed. The main work is as follow: according to the diffident power transmission calculation methods of droop control in grid-connected mode and island mode, the adaptive switching is realized by detecting the current and frequency at Point of Common Coupling(PCC) of public power grid. Secondly, the switching from island mode to grid-connected mode will cause impact due to the difference of frequency, phase and amplitude between microgrid and public grid, and even cause system collapse. So the pre-synchronization control of frequency, phase and amplitude is designed. Based on the droop control, the disturbance observation(DOB) is added, which can quickly track the sudden change of system current, and suppress the sudden change by the difference between the tracking value and the actual value, so as to realize the smooth switching from island to grid. Finally, the effectiveness and feasibility of the control strategy are verify in Matlab/Simulink.
4 December 2020 in IEEE Access
The nonlinear load in AC/DC hybrid microgrid seriously affects the power transmission quality of bidirectional AC/DC interlinking converter (BIC). In this paper, an improved Fryze-Buchholz-Depenbrock (FBD) harmonic current detection method combined with droop control is designed to suppress harmonic current control strategy. The decoupled double synchronous reference frame phase locked loop (DDSRF-PLL) with self decoupled network is used to eliminate the negative sequence fundamental frequency component, and the accurate phase detection can also be realized when affected by nonlinear load. The least mean square (LMS) algorithm adaptive filter can enhance the dynamic response ability when the load current suddenly changes. To solve the problem that the cut-off frequency of low pass filter (LPF) can not take into account the detection accuracy and response speed of FBD harmonic current detection method. Finally, Matlab/Simulink is used for simulation verification. The simulation results show that the improved control strategy not only realizes the bidirectional flow of power and maintains the DC bus voltage stability, but also reduces the total harmonic distortion (THD) at point of common coupling (PCC) by 0.45% compared with the traditional FBD control strategy. And the effectiveness and feasibility of the design method are proved.