Raphael Anaadumba

Raphael Anaadumba

Auto-generated profile, based on publicly available information

Raphael Anaadumba

University of Massachusetts Lowell, Lowell, MA, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2021 in Cybersecurity
Verified
Journal Article
Open access
PDF file
RARaphael Anaadumba
Raphael Anaadumba
QLQi Liu
Qi Liu
BMBockarie Daniel Marah
Bockarie Daniel Marah
FNFrancis Mawuli Nakoty
Francis Mawuli Nakoty
XLXiaodong Liu
Xiaodong Liu
YZYonghong Zhang
Yonghong Zhang
Energy forecasting using Renewable energy sources (RESs) is gradually gaining weight in the research field due to the benefits it presents to the modern-day environment. Not only does energy forecasting using renewable energy sources help mitigate the greenhouse effect, it also helps to conserve energy for future use. Over the years, several methods for energy forecasting have been proposed, all of which were more concerned with the accuracy of the prediction models with little or no considerations to the operating environment. This research, however, proposes the uses of Deep Neural Network (DNN) for energy forecasting on mobile devices at the edge of the network. This ensures low latency and communication overhead for all energy forecasting operations since they are carried out at the network periphery. Nevertheless, the cloud would be used as a support for the mobile devices by providing permanent storage for the locally generated data and a platform for offloading resource-intensive computations that exceed the capabilities of the local mobile devices as well as security for them. Electrical network topology was proposed which allows seamless incorporation of multiple RESs into the distributed renewable energy source (D-RES) network. Moreover, a novel grid control algorithm that uses the forecasting model to administer a well-coordinated and effective control for renewable energy sources (RESs) in the electrical network is designed. The electrical network was simulated with two RESs and a DNN model was used to create a forecasting model for the simulated network. The model was trained using a dataset from a solar power generation company in Belgium (elis) and was experimented with a different number of layers to determine the optimum architecture for performing the forecasting operations. The performance of each architecture was evaluated using the mean square error (MSE) and the r-square.

13 June 2025 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
NBNazim A. Belabbaci
Nazim A. Belabbaci
RARaphael Anaadumba
Raphael Anaadumba
MAMohammad Arif Ul Alam
Mohammad Arif Ul Alam
Background: Monitoring hydration is crucial for maintaining health and preventing dehydration. Despite the potential of wearable devices for continuous hydration monitoring, health research hasn’t fully explored this application, and clear design guidelines are absent. This scoping review aimed to address this gap by analyzing current research trends and assessing the potential impact of wearable technologies for hydration monitoring. Objective: This review comprehensively examined recent advancements in wearable hydration-monitoring technologies, focusing on their capabilities, limitations, and research and prototype designs. It explored various sensors and technologies used to track hydration, compared their advantages and disadvantages, identified trends in wearable hydration-monitoring devices, evaluated their accuracy and reliability against established benchmarks, and reviewed commercially available products to bridge research findings and practical applications. Methods: Following the PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews) guidelines, we systematically searched PubMed, IEEE Xplore, and Google Scholar for studies (2014-2024) on noninvasive wearable devices that used physiological biomarkers. Validation with human participants or comparisons with gold standards was required. Data extraction covered study characteristics, sensor technologies, validation methods, and commercial product analysis. In addition to academic research papers, gray literature was included through a Google Scholar search to investigate commercial products in the field of hydration monitoring. This approach ensured a broader perspective on technological advancements and market trends. Results: The review synthesized 63 articles selected from 156 included for full-text analysis. The literature was categorized based on sensor types, including electrical, optical, thermal, microwave, and multimodal sensors. Most studies (47/63, 75%) examined the effects of hydration on physiological parameters, with some (16/63, 25%) focusing on hydration status during physical activity or in specific environmental conditions. Commercially available products from 8 companies were also evaluated for their technological features, functionalities, and applications. The dominance of electrical sensors in research was highlighted due to their ease of use and integration into wearable devices. While fewer in number, optical sensors demonstrated higher precision and provided molecular-level insights. The emergence of multimodal sensors suggests a trend toward combining technologies to improve accuracy, as reflected by their increasing publication share. Other sensors, such as thermal and microwave-based sensors, occupied specialized niches. The growing acceptance of optical-based wearables in the market reflects their cost-to-precision effectiveness. Conclusions: Wearable hydration-monitoring devices provide real-time assessments of hydration status, but challenges remain in ensuring their reliability, accuracy, and applicability across diverse populations and conditions. Future directions for research include standardized protocols, extensive clinical trials, sensor miniaturization, and enhanced wearability. Multimodal systems that integrate various sensors with artificial intelligence–driven analysis hold promise for personalized hydration management. This review offers detailed insights into the strengths and challenges of sensor technologies, paving the way for practical skin hydration-monitoring solutions.

15 May 2024 in JMIR Preprints
Verified
Preprint
Open access
NBNazim Belabbaci
Nazim Belabbaci
RARaphael Anaadumba
Raphael Anaadumba
MAMohammad Arif Ul Alam
Mohammad Arif Ul Alam
BACKGROUND Monitoring hydration is crucial for maintaining health and preventing dehydration-related is-sues. Wearable devices offer a promising method for continuously tracking hydration levels. Despite the popularity of wearable technology in health research, its application for hydration monitoring is not extensively studied, and clear design guidelines are lacking. This scoping review aims to fill this gap by analyzing existing research trends and the potential impact of wearable technologies for hydration monitoring. OBJECTIVE This review comprehensively analyzes recent advancements in wearable hydration monitoring technologies, focusing on their capabilities, limitations, and research and prototype designs. It explores different sensors and technologies for tracking hydration, compares their ad-vantages and disadvantages, identifies trends in wearable hydration monitoring devices, assesses their accuracy and reliability compared to established benchmarks, and identifies commercially available products to bridge research findings with practical use. METHODS Following PRISMA guidelines, a scoping review was conducted to explore the breadth and variety of technological approaches in hydration monitoring research. A systematic search across Pubmed, IEEE Xplore, and Google Scholar was performed using a versatile search syntax. Studies published since 2014 focusing on non-invasive, portable hydration monitoring systems utilizing physiological biomarkers were included. RESULTS The review included 63 articles selected from 156 studies for synthesis analysis. The literature was categorized based on sensor types, including electrical, optical, thermal, microwave, and multimodal sensors. Most studies explored hydration’s effects on physiological parameters, with some examining hydration status during physical activity or in various environmental conditions. Commercially available products from eight companies were also evaluated for technological features, functionalities, and applications. The dominance of electrical sensors in re- search was noted, leveraging their ease of use and integration into wearables. While fewer in number, optical methods exhibited precision and provided molecular-level in-sights. The emergence of multimodal sensors indicated a trend toward combining technologies for better ac- curacy. Other sensors, such as thermal and microwave-based variants, found unique niches. The prevalence of optical-based wearables in the market suggests their growing acceptance due to cost-to-precision effectiveness. CONCLUSIONS Wearable hydration monitoring devices offer real-time hydration assessments, but challenges remain in reliability, accuracy, and applicability across diverse populations and conditions. Future directions include standardized protocols, extensive clinical studies, sensor miniaturization, and improved wearability. Multimodal systems combining various sensors with AI-driven analysis offer potential for personalized hydration management. This review provides detailed insights into sensor technologies’ strengths and challenges, paving the way for practical solutions in skin hydration monitoring.