Matthieu Schoumacher

Matthieu Schoumacher

Auto-generated profile, based on publicly available information

Matthieu Schoumacher

Clinical Chemistry, CIRM, University of Liège, Quartier Hopital, Avenue Hippocrate, 15, Liège 4000, Belgium

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2025 in Journal of Mass Spectrometry and Advances in the Clinical Lab
Verified
Journal Article
Open access
EGE. Grifnée
E. Grifnée
AMA. Mackowiak
A. Mackowiak
JDJ. Demeuse
J. Demeuse
MSM. Schoumacher
M. Schoumacher
LHL. Huyghebaert
L. Huyghebaert
CGC.LE Goff
C.LE Goff
Oxytocin is a 9-amino acid peptide that serves as neuromodulator in the human central nervous system. This peptide is implicated in the regulation of diverse behaviors and plays a significant role in positive social interaction. Currently, oxytocin levels are measured using immunoassays. However, these methods have several limitations that can lead to false results and erroneous interpretation. Given the remarkably low endogenous level of oxytocin in human plasma (low ng/L levels), we developed and rigorously validated a novel and highly sensitive LC-MS/MS method for oxytocin quantification in plasma. Oxytocin was initially extracted using solid-phase extraction with an Oasis HLB 30 mg plate and then subjected to LC-MS/MS analysis. PBS-0.1 % BSA served as surrogate matrix for the preparation of validation samples and the calibration curve, ensuring no endogenous interference. The validation design followed the Clinical Laboratory Standards Institute guidelines. Precision, accuracy, and measurement uncertainty were determined using single-nested analysis of variance and e.noval software. A lower limit of quantification of 1 ng/L was achieved. The method was validated for oxytocin concentrations ranging from 1 ng/L to 75 ng/L, with precision (coefficient of variation) below 10 %, accuracy ranging from 94 % to 108 %, and measurement uncertainty below 15 %. In this work, we developed and validated a highly sensitive LC-MS/MS method for the quantification of oxytocin in plasma. Our novel methodology is well-suited for clinical applications.

3 January 2026 in Animal Reproduction Science
Verified
Journal Article
Closed access
JLJoy Ledeck
Joy Ledeck
TDThomas Dubrowski
Thomas Dubrowski
MSMatthieu Schoumacher
Matthieu Schoumacher
SPStéphanie Peeters
Stéphanie Peeters
CGCaroline Le Goff
Caroline Le Goff
JPJerôme Ponthier
Jerôme Ponthier

19 December 2024 in European Journal of Medicinal Chemistry Reports
Verified
Journal Article
Open access
MSMichael Schnekenburger
Michael Schnekenburger
EGEric Goffin
Eric Goffin
MSMatthieu Schoumacher
Matthieu Schoumacher
NTNikolay Tumanov
Nikolay Tumanov
AMAnge Mouithys-Mickalad
Ange Mouithys-Mickalad
BPBernard Pirotte
Bernard Pirotte