Zuzana Sajdlova

Zuzana Sajdlova

Auto-generated profile, based on publicly available information

Zuzana Sajdlova

BVT Technologies, 612 00 Brno, Czech Republic

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2014 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
JKJan Krejci
Jan Krejci
ZSZuzana Sajdlova
Zuzana Sajdlova
VNVilém Neděla
Vilém Neděla
EFEva Flodrova
Eva Flodrova
RSRomana Sejnohova
Romana Sejnohova
RPRobert Plicka
Robert Plicka
The article compares the determination of an SPE (Screen Printed Electrodes) electrochemical active surface (AS) by the analysis of cyclic voltammogram in ferro-ferricyanide using Koutecky equation and by confocal and electron microscopy. SPE reliability is influenced by mass transport of analyte to active electrode surface while the physical properties of SPE are reproducible and stable. The electrode reaction involves the upper layer of SPE. The AS is the same as the geometrical area. Other methods set the active/geometrical area relation to 2,03 ± 0,04 (gold working electrode) and 4,35 ± 0,08 (platinum working electrode). It is demonstrated that nanostructures on working electrode surface can be efficient at high frequencies (>10 kHz). The active area of SPE determined by scanning electron microscopy or optical measurement exhibits a standard deviation lower than 2%. It proves SPE be reliable and precise electrochemical device under optimal hydrodynamic conditions.

14 July 2010 in Sensors
Verified
Journal Article
Open access
PDF file
JKJan Krejci
Jan Krejci
ZSZuzana Sajdlova
Zuzana Sajdlova
JKJan Krejci
Jan Krejci
TMTomas Marvanek
Tomas Marvanek
Electrochemical measurements are generally done under isothermal conditions. Here we report on the application of a controlled temperature gradient between the working electrode surface and the solution. Using electrochemical sensors prepared on ceramic materials with extremely high specific heat conductivity, the temperature gradient between the electrode and solution was applied here as a second driving force. This application of the Soret phenomenon increases the mass transfer in the Nernst layer and enables more accurate control of the electrode response enhancement by a combination of diffusion and thermal diffusion. We have thus studied the effect of Soret phenomenon by cyclic voltammetry measurements in ferro/ferricyanide. The time dependence of sensor response disappears when applying the Soret phenomenon, and the complicated shape of the cyclic voltammogram is replaced by a simple exponential curve. We have derived the Cotrell-Soret equation describing the steady-state response with an applied temperature difference.