1 May 2018 in Electrochimica Acta
1 October 2022 in Journal of Structural Engineering
High-performance fiber-reinforced cement-based composite (HPFRCC) is a class of construction materials that exhibit pseudo-strain hardening behavior under tension after first cracking and gradual softening behavior under compression after crushing. Compared to conventional concrete, the enhanced tension and compression performance make HPFRCC promising for earthquake-resistant structures. Extensive studies have explored the seismic performance of reinforced HPFRCC with different material designs and in different structural forms, while real-world applications are emerging. This paper is intended to summarize the collective knowledge that the research community has gained and to identify future research needs. We review (1) HPFRCC cyclic performance on the material level, (2) seismic performance of reinforced HPFRCC flexural members, including beams and columns, (3) shear-dominant members, covering coupling beams and structural walls, and (4) the behavior and design of HPFRCC beam-column joints. We conclude with key challenges and opportunities for the research and professional community.
1 August 2017 in Composite Structures
1 March 2019 in Engineering Structures
1 August 2018 in Corrosion Science
23 September 2016 in Key Engineering Materials
Many reinforced concrete structures susceptible to corrosion damage are subjected to externally applied loads, causing cracking. These cracks increase the permeability of the material, accelerating the ingress of corrosion-inducing deleterious agents. In this paper, the effect of multiple microcracking and macrocrack formation on corrosion initiation was investigated. A hybrid fiber-reinforced concrete (HyFRC), which forms ductile, distributed microcracking prior to dominant crack localization due to multiple tiers of fiber reinforcement, is being studied for its performance against corrosion damage. The effect of matrix cracking on corrosion initiation was studied with beam specimens preloaded in flexure prior to long-term corrosion exposure. Reinforced HyFRC composites were found to have a delayed corrosion initiation response due to reductions in crack widths and suppression of splitting cracks, compared to conventional reinforced concrete. The influence of microcracks on corrosion is studied using X-ray micro-computed tomography (μCT) on reinforced fiber-reinforced cementitious composites and reinforced mortar preloaded in tension.