Julia G. Konyukhova

Julia G. Konyukhova

Auto-generated profile, based on publicly available information

Julia G. Konyukhova

Saratov State University, 83, Astrakhanskaya st., Saratov 410012, Russia

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
EVElena K. Volkova
Elena K. Volkova
Irina YaninaIrina Yanina
Irina Yanina
Elina A. GeninaElina A. Genina
Elina A. Genina
ABAlexey N. Bashkatov
Alexey N. Bashkatov
JKJulia G. Konyukhova
Julia G. Konyukhova
Valery TuchinValery Tuchin
Valery Tuchin
The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.

5 November 2013 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
VKVyacheslav Kochubey
Vyacheslav Kochubey
EVElena K. Volkova
Elena K. Volkova
JKJulia G. Konyukhova
Julia G. Konyukhova
The effect of glucose on fluorescence of synthesized ZnCdS nanoparticles in the presence of glucose oxidase or in a mixture of glucose oxidase and peroxidase has been investigated. Behavior of fluorescence characteristics of ZnCdS nanoparticles with nonstabilized surface and coated with polymer shell is compared. It has been shown that, for uncoated ZnCdS nanoparticles, hydrogen peroxide formed by glucose oxidation with glucose oxidase causes static quenching of the nanoparticle fluorescence. A quenching mechanism is proposed in which surface centers of fluorescence, which include cationic vacancies, trap oxygen ions supplied by hydrogen peroxide. It has been shown that the linear Stern–Volmer plot has no threshold within the investigated concentrations of glucose. The sensitivity of ZnCdS nanoparticles to glucose, determined from the slope of linear Stern–Volmer plot, is maximum for polymer-coated nanoparticles and is 12.2  ml/mg. With peroxidase, there is a threshold concentration of glucose (160 μM) below which the nanoparticles become insensitive to glucose.

31 December 2019 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
ESElena A. Sagaidachnaya
Elena A. Sagaidachnaya
JKJulia G. Konyukhova
Julia G. Konyukhova
NKNatalia I. Kazadaeva
Natalia I. Kazadaeva
ADAnna Doronkina
Anna Doronkina
Irina YaninaIrina Yanina
Irina Yanina
VKVyacheslav I. Kochubey
Vyacheslav I. Kochubey
<!-- *** Custom HTML *** --> The excitation power dependence of upconversion luminescence intensity and temperature sensing characteristics are investigated in the NaYF4 : Er3  +  , Yb3  +   @ SiO2 particles synthesized in-house using a hydrothermal method. The effect of laser-induced heating of the upconversion particles is shown, which introduces distortions in the measured power and temperature dependences of the upconversion luminescence. We propose a technique for calibrating the temperature dependence of upconversion particle luminescence, which should improve the accuracy of temperature measurements. The technique is based on the stabilization of upconversion particles temperature, which provides the suppression of laser-induced heating of upconversion particles.

18 August 2021 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
MKMarina Kozintseva
Marina Kozintseva
VKVyacheslav Kochubey
Vyacheslav Kochubey
JKJulia Konyukhova
Julia Konyukhova
Valery TuchinValery Tuchin
Valery Tuchin
The current work is focused on the study of optical clearing of skeletal muscles under local compression. The experiments were performed on in vitro bovine skeletal muscle. The time dependence of optical clearing was studied by monitoring the luminescence intensity of NaYF4:Er,Yb upconverting particles located under tissue layers. This study shows the possibility to use upconverting nanoparticles (UCNPs) both for studying the dynamics of the optical clearing of biological tissue under compression and to detect moments of cell wall damage under excessive pressure. The advantage of using UCNPs is the presence of several bands in their luminescence spectra, located both at close wavelengths and far apart.