The article presents the results of a retrospective analysis of viral hepatitis B incidence in the Russian Federation from 2013 to 2017, taking into account the use of vaccines included into the National Immunisation Schedule and the Immunisation Programme in Case of Epidemic Outbreaks. The analysis of the data revealed a trend towards a reduction in the incidence of acute and chronic forms of hepatitis B in the territory of the Russian Federation during the past five years. The reduction of viral hepatitis B incidence was achieved thanks to a higher vaccination coverage of both children and adults. The article presents an overview of monovalent and combination recombinant hepatitis B vaccines licensed in the Russian Federation. It describes the WHO position on preventive vaccination against viral hepatitis B, and pays special attention to vaccination of people at risk. The article considers promising areas for improving immunobiological products for hepatitis B prevention, including new technologies used in vaccine production, development and introduction of new adjuvants or adjuvants systems, and development of therapeutic vaccines.
13 September 2023 in Biological Products. Prevention, Diagnosis, Treatment
Scientific relevance. The immunoglobulin A (IgA) impurity content in parenteral human immunoglobulins should be determined in accordance with the State Pharmacopoeia of the Russian Federation by kinetic nephelometry, radial immunodiffusion, or enzyme immunoassay (ELISA) with a reference standard. The International Standard (IS) for the content of IgA is certified using gravimetry and radial immunodiffusion. However, neither of the existing standards for the content of IgA in human immunoglobulins is currently certified using all three compendial methods. This prevents analysts from comparing test results obtained by different methods and may lead to an underestimation of the IgA content in human immunoglobulins.Aim. This study aimed to determine the procedure for the development, certification, and use of a pharmacopoeial reference standard (RS) for the content of IgA in human immunoglobulins.Materials and methods. The authors studied candidate RSs for the IgA content derived from human plasma for fractionation. The IgA content determination involved kinetic nephelometry, radial immunodiffusion, and ELISA, as well as commercial test kits and the IS. The authors quantified the IgA impurity in samples of commercial human immunoglobulins from various manufacturers. The data analysis involved descriptive statistics and variance analysis using Microsoft Excel and Statistica 10.Results. The authors established a pharmacopoeial standard with a certified IgA content of 1.98 mg/mL (expanded uncertainty, 0.44 mg/mL; coverage coefficient, k=2; confidence level, 95%) for IgA impurity quantification in human immunoglobulins by radial immunodiffusion and ELISA and that of 1.31–2.64 mg/mL (expanded uncertainty, 0.67 mg/mL; coverage ratio, k=3; confidence level, 99%) for intralaboratory quality control of IgA impurity quantification by kinetic nephelometry, radial immunodiffusion, and ELISA.Conclusions. The pharmacopoeial standard developed in the study has been included in the register of standards of the State Pharmacopoeia of the Russian Federation as the Reference Standard for the Content of Immunoglobulin Class A (IgA) (Registry No. 3.1.00454). The pharmacopoeial standard is intended for the standardisation of analytical methods for the-determination of the IgA impurity content in parenteral human immunoglobulins.
17 August 2023 in Biological Products. Prevention, Diagnosis, Treatment
Scientific relevance. Anti-hepatitis B virus surface-antigen (HBsAg) immunoglobulins are used to prevent hepatitis B in adults and children after exposure and to treat mild to moderate acute viral hepatitis B. The clinical effectiveness of human immunoglobulin preparations is determined by their potency, which is assessed by the content of antibodies to hepatitis B virus surface antigen (anti-HBs antibodies). Currently, this assessment involves using immunoassay techniques, such as enzyme-linked immunosorbent assay (ELISA).Aim. This study examined several mathematical methods for analysing the experimental data obtained in ELISA-based anti-HBs antibody potency assays of human immunoglobulin preparations.Materials and methods. This study used the international standard for human anti-HBs immunoglobulin, two immunoglobulin preparations, and an ELISA test kit for the detection and quantification of anti-HBs antibodies in serum or plasma samples.Results. Using sandwich ELISA, the authors ascertained that the measured anti-HBs antibody concentration depended on the choice of calibration curve calculation method (i.e. manual analysis, parallel-line analysis using PARALINE software, linear regression, and 4-parameter logistic regression). The measured anti-HBs antibody concentrations varied by ± 19 IU/mL. According to the study results, an incorrectly selected method of data analysis can lead to an erroneous calculation of the analyte potency (concentration) in the test sample.Conclusions. The study demonstrated the need for improved mathematical methods for the evaluation of experimental data used to determine the anti-HBs antibody concentration in human immunoglobulin preparations. It is essential to switch from manual to automated calculation (for example, using a 4-parameter logistic model), taking into account the requirements for bioanalytical methods and the capabilities of the available equipment.
Представлен аналитический обзор по методам количественного определения фактора свертывания крови VIII в лекарственных препаратах и используемых для этих целей стандартных образцах в международной фармацевтической практике. Приведены методические особенности разработки и аттестации серий международного стандартного образца фактора свертывания крови VIII, а также серий стандартного образца Европейской фармакопеи. Показано, что для обеспечения надлежащего контроля качества лекарственных препаратов фактора свертывания крови VIII отечественным производителям необходимо наличие национального фармакопейного стандартного образца. Установлена необходимость разработки фармакопейного стандартного образца фактора свертывания крови VIII, калиброванного в международных единицах, для Государственной фармакопеи Российской Федерации. С целью дальнейшей разработки национального стандартного образца предложена реализация нескольких подходов.