Ahmad Hosseini

Ahmad Hosseini

Auto-generated profile, based on publicly available information

Ahmad Hosseini

School of Railway Engineering, Iran University of Science and Technology, Tehran, Iran

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
Morteza EsmaeiliMorteza Esmaeili
Morteza Esmaeili
PAP. Aela
P. Aela
AHA. Hosseini
A. Hosseini

1 March 2016 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
Morteza EsmaeiliMorteza Esmaeili
Morteza Esmaeili
SHS.A.S. Hosseini
S.A.S. Hosseini
MSM. Sharavi
M. Sharavi

1 February 2019 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
Morteza EsmaeiliMorteza Esmaeili
Morteza Esmaeili
PAPeyman Aela
Peyman Aela
AHAhmad Hosseini
Ahmad Hosseini
The optimum weight percentage of tire-derived aggregates (TDAs) mixed with ballast, as a new approach to rehabilitate the performance of ballast layer in desert areas, has been suggested as 5% in the presence of sand fouling. The current paper is devoted to the effect of moisture content (MC) on the mechanical behavior of sand-fouled ballast with and without TDAs. A number of ballast box cyclic tests were conducted on mixtures of fully fouled ballast, TDA, and water. The samples contained 0% and 5% of TDAs by ballast weight as well as 0%, 5%, 10%, 15%, and 20% of MC by sand weight. The gradation of ballast and TDAs was in accordance with current standards, and the particle size distribution of sand ranged from 0.075 to 0.84 mm. The parameters measured are the settlement, stiffness, and damping of samples, which did not follow a constant trend by varying the MC. According to the laboratory results, an MC of 5% decreased the settlement and increased the stiffness and damping of fouled non-TDA samples, whereas increasing the MC up to 10%, these samples experienced their minimum stiffness as well as maximum settlement and damping. Inclusion of TDAs had no effects on the variation trend of settlement and stiffness versus the MC. Consequently, from a practical standpoint, the MC of 10%, which eliminated the influence of TDAs on the sample damping, was regarded as the critical moisture content.

7 May 2018 in Road Materials and Pavement Design
Verified
Journal Article
Closed access
Morteza EsmaeiliMorteza Esmaeili
Morteza Esmaeili
SMSaeed Majidi-Parast
Saeed Majidi-Parast
AHAhmad Hosseini
Ahmad Hosseini
This paper was devoted to investigating and comparing the dynamic lateral resistance (DLR) of various types of sleepers under lateral impact loading conditions. In this regard, a series of impact tests were conducted on concrete, wooden and steel sleepers in the laboratory, using an inventive pendulum loading test device (PLTD). In loading tests, different masses and triggering angles for the PLTD hammer, the impact load, inertia force and lateral displacement of sleepers were recorded by instrumenting the hammer and sleepers. Furthermore, in order to compare the ballast–sleeper interaction force diagrams in dynamic and static states of loading, a number of single tie (sleeper) push tests (STPTs) were accomplished in a similar circumstance. The laboratory results showed the insufficiency of steel sleeper in providing the DLR against impact loads in comparison with concrete and wooden sleepers. Moreover, the maximum DLR of concrete, wooden and steel sleepers were calculated as 12.2, 5.1 and 2.35 kN, which were considerably higher than their static lateral resistances (SLRs) of 6.2, 3.1 and 1.75 kN, respectively. Assuming an impact coefficient as the DLR/SLR ratio, the values of 1.98, 1.65 and 1.34 were attained for the mentioned sleepers, indicating a very good agreement with the value of 200% suggested by the American Railway Engineering and Maintenance-of-Way Association [AREMA. (2006). Manual for railway engineering. Lanham, MD: Author] for a concrete sleeper.

1 March 2018 in Canadian Geotechnical Journal
Verified
Journal Article
Closed access
AZAli-Asghar Zekavati
Ali-Asghar Zekavati
AKAlireza Khodaverdian
Alireza Khodaverdian
MJMohammad-Ali Jafari
Mohammad-Ali Jafari
AHAhmad Hosseini
Ahmad Hosseini
This paper captures the behavior of micropiled rafts in power transmission line tower foundations in cohesive soil, concentrating on their uplift performance whether due to the tower position along the line or under wind loading conditions. In this regard, first a number of micropiles were driven into the ground of a project site at the ParehSar power plant, Gilan, Iran. Compression and uplift loading tests were conducted according to relevant standards. On the basis of the field data, a three-dimensional finite element model was developed and subsequently calibrated and verified. The behavior of micropiled rafts subjected to uplift, which is a typical type of loading in foundations of 230 kV four-circuit lattice towers, was then studied by means of this model in terms of a wide-ranging parametric study. In the sensitivity analyses, the impacts of various parameters, such as micropile spacing-to-diameter (s/d) and length-to-diameter (l/d) ratios along with undrained shear strength of the soil, on the uplift capacity of an individual micropile within and out of the group were investigated. Furthermore, interaction factors were computed based on diverse values for undrained shear strength of the soil, s/d ratio, l/d ratio, and grout–soil adhesion. From design and analysis perspectives, the finite element method (FEM) outputs revealed that the efficiency coefficient of micropiled rafts during uplift can be considered equal to one. Moreover, it was found that not only does the behavior of micropiles affect the neighboring micropiles immediately adjacent to the loaded one, but it also influences those in further rows, the result of which would be considering their significance as well.

7 March 2016 in Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit
Verified
Journal Article
Closed access
AHAhmad Hosseini
Ahmad Hosseini
Morteza EsmaeiliMorteza Esmaeili
Morteza Esmaeili
The amount of ballast particles surrounding a railway track significantly influences its resistance in all directions. As time goes by, with the development of high-speed trains, more attention has been paid to this issue owing to the increase in dynamic effects of rolling stock on track loading. The focus of the present study is on the investigation of the interaction between different surfaces (base, crib, and shoulder) of concrete sleeper and their adjacent ballast layer along with the related parameters under lateral impact loading condition. In this regard, by utilizing a pendulum loading test device, a number of lateral impact tests were conducted on an instrumented concrete sleeper in laboratory. On the basis of experimental results, the average contribution of base, crib, and shoulder zones in the total dynamic lateral resistance of sleeper was calculated as 48%, 23%, and 29%, respectively. Furthermore, in the lateral impact force domain of 13–28 kN, the sleeper–ballast dynamic friction coefficient at base and crib zones varied in the ranges 0.8–1.5 and 0.5–0.6. Moreover, a maximum impact factor of 2.5 was obtained for analysis and design purposes. It should be stated that the trend of laboratory results confirmed the common static friction coefficient of 0.8.