Arne Ludwig

Arne Ludwig

Auto-generated profile, based on publicly available information

Arne Ludwig

Leibniz-Institute for Zoo and Wildlife Research, Berlin, Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2022 in GigaScience
Verified
Journal Article
Open access
PDF file
ALArne Ludwig
Arne Ludwig
MPMartin Pippel
Martin Pippel
GMGene Myers
Gene Myers
MHMichael Hiller
Michael Hiller
Long sequencing reads allow increasing contiguity and completeness of fragmented, short-read–based genome assemblies by closing assembly gaps, ideally at high accuracy. While several gap-closing methods have been developed, these methods often close an assembly gap with sequence that does not accurately represent the true sequence. Here, we present DENTIST, a sensitive, highly accurate, and automated pipeline method to close gaps in short-read assemblies with long error-prone reads. DENTIST comprehensively determines repetitive assembly regions to identify reliable and unambiguous alignments of long reads to the correct loci, integrates a consensus sequence computation step to obtain a high base accuracy for the inserted sequence, and validates the accuracy of closed gaps. Unlike previous benchmarks, we generated test assemblies that have gaps at the exact positions where real short-read assemblies have gaps. Generating such realistic benchmarks for Drosophila (134 Mb genome), Arabidopsis (119 Mb), hummingbird (1 Gb), and human (3 Gb) and using simulated or real PacBio continuous long reads, we show that DENTIST consistently achieves a substantially higher accuracy compared to previous methods, while having a similar sensitivity. DENTIST provides an accurate approach to improve the contiguity and completeness of fragmented assemblies with long reads. DENTIST's source code including a Snakemake workflow, conda package, and Docker container is available at https://github.com/a-ludi/dentist. All test assemblies as a resource for future benchmarking are at https://bds.mpi-cbg.de/hillerlab/DENTIST/.

13 January 2023 in Oryx
Verified
Journal Article
Open access
PDF file
Leonardo CongiuLeonardo Congiu
Leonardo Congiu
JGJoern Gessner
Joern Gessner
ALArne Ludwig
Arne Ludwig

24 May 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
ALArne Ludwig
Arne Ludwig
ADAlexandr Dibrov
Alexandr Dibrov
GMGene Myers
Gene Myers
MPMartin Pippel
Martin Pippel
Highly contiguous genome assemblies are essential for genomic research. Chromosome-scale assembly is feasible with the modern sequencing techniques in principle, but in practice, scaffolding errors frequently occur, leading to incorrect number and sizes of chromosomes. Relating the observed chromosome sizes from karyotype images to the generated assembly scaffolds offers a method for detecting these errors. Here, we present KICS, a semi-automated approach for estimating relative chromosome sizes from karyotype images and their subsequent comparison to the corresponding assembly scaffolds. The method relies on threshold-based image segmentation and uses the computed areas of the chromosome-related connected components as a proxy for the actual chromosome size. We demonstrate the validity and practicality of our approach by applying it to karyotype images of humans and various amphibians, birds, fish, insects, mammals, and plants. We found a strong linear relationship between pixel counts and the DNA content of chromosomes. Averaging estimates from eight human karyotype images, KICS predicts most of the chromosome sizes within an error margin of just 6 Mb. Our method provides additional means of validating genome assemblies at low costs. An interactive implementation of KICS is available at https://github.com/mpicbg-csbd/napari-kics .

27 February 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
ALArne Ludwig
Arne Ludwig
MPMartin Pippel
Martin Pippel
GMGene Myers
Gene Myers
MHMichael Hiller
Michael Hiller
Background: Long sequencing reads allow increasing contiguity and completeness of fragmented, short-read based genome assemblies by closing assembly gaps, ideally at high accuracy. While several gap closing methods have been developed, these methods often close an assembly gap with sequence that does not accurately represent the true sequence. Findings: Here, we present DENTIST, a sensitive, highly accurate and automated pipeline method to close gaps in short-read assemblies with long error-prone reads. DENTIST comprehensively determines repetitive assembly regions to identify reliable and unambiguous alignments of long reads to the correct loci, integrates a consensus sequence computation step to obtain a high base accuracy for the inserted sequence, and validates the accuracy of closed gaps. Unlike previous benchmarks, we generated test assemblies that have gaps at the exact positions where real short-read assemblies have gaps. Generating such realistic benchmarks for Drosophila (134 Mb genome), Arabidopsis (119 Mb), hummingbird (1 Gb) and human (3 Gb) and using simulated or real PacBio continuous long reads, we show that DENTIST consistently achieves a substantially higher accuracy compared to previous methods, while having a similar sensitivity. Conclusion: DENTIST provides an accurate approach to improve the contiguity and completeness of fragmented assemblies with long reads. DENTIST’s source code including a Snakemake workflow, conda package and Docker container is available at https://github.com/a-ludi/dentist . All test assemblies as a resource for future benchmarking are at https://bds.mpi-cbg.de/hillerlab/DENTIST/ .