26 February 2008 in Journal of Magnetic Resonance Imaging
The Alzheimer's Disease Neuroimaging Initiative (ADNI) is a longitudinal multisite observational study of healthy elders, mild cognitive impairment (MCI), and Alzheimer's disease. Magnetic resonance imaging (MRI), (18F)‐fluorodeoxyglucose positron emission tomography (FDG PET), urine serum, and cerebrospinal fluid (CSF) biomarkers, as well as clinical/psychometric assessments are acquiredat multiple time points. All data will be cross‐linked and made available to the general scientific community. The purpose of this report is to describe the MRI methods employed in ADNI. The ADNI MRI core established specifications thatguided protocol development. A major effort was devoted toevaluating 3D T1‐weighted sequences for morphometric analyses. Several options for this sequence were optimized for the relevant manufacturer platforms and then compared in a reduced‐scale clinical trial. The protocol selected for the ADNI study includes: back‐to‐back 3D magnetization prepared rapid gradient echo (MP‐RAGE) scans; B1‐calibration scans when applicable; and an axial proton density‐T2 dual contrast (i.e., echo) fast spin echo/turbo spin echo (FSE/TSE) for pathology detection. ADNI MRI methods seek to maximize scientific utility while minimizing the burden placed on participants. The approach taken in ADNI to standardization across sites and platforms of the MRI protocol, postacquisition corrections, and phantom‐based monitoring of all scanners could be used as a model for other multisite trials. J. Magn. Reson. Imaging 2008.
20 June 2012 in Diagnostic Pathology
Immunohistochemical (IHC) assays performed on formalin-fixed paraffin-embedded (FFPE) tissue sections traditionally have been semi-quantified by pathologist visual scoring of staining. IHC is useful for validating biomarkers discovered through genomics methods as large clinical repositories of FFPE specimens support the construction of tissue microarrays (TMAs) for high throughput studies. Due to the ubiquitous availability of IHC techniques in clinical laboratories, validated IHC biomarkers may be translated readily into clinical use. However, the method of pathologist semi-quantification is costly, inherently subjective, and produces ordinal rather than continuous variable data. Computer-aided analysis of digitized whole slide images may overcome these limitations. Using TMAs representing 215 ovarian serous carcinoma specimens stained for S100A1, we assessed the degree to which data obtained using computer-aided methods correlated with data obtained by pathologist visual scoring. To evaluate computer-aided image classification, IHC staining within pathologist annotated and software-classified areas of carcinoma were compared for each case. Two metrics for IHC staining were used: the percentage of carcinoma with S100A1 staining (%Pos), and the product of the staining intensity (optical density [OD] of staining) multiplied by the percentage of carcinoma with S100A1 staining (OD*%Pos). A comparison of the IHC staining data obtained from manual annotations and software-derived annotations showed strong agreement, indicating that software efficiently classifies carcinomatous areas within IHC slide images. Comparisons of IHC intensity data derived using pixel analysis software versus pathologist visual scoring demonstrated high Spearman correlations of 0.88 for %Pos (p < 0.0001) and 0.90 for OD*%Pos (p < 0.0001). This study demonstrated that computer-aided methods to classify image areas of interest (e.g., carcinomatous areas of tissue specimens) and quantify IHC staining intensity within those areas can produce highly similar data to visual evaluation by a pathologist. Virtual slides: The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1649068103671302
18 March 2003 in Magnetic Resonance in Medicine
GSGreta Sartoni‐D'Ambrosia
+2
28 January 2008 in Magnetic Resonance in Medicine
High‐quality prostate images were obtained with transceiver arrays at 7T after performing subject‐dependent local transmit B1 (B1+) shimming to minimize B1+ losses resulting from destructive interferences. B1+ shimming was performed by altering the input phase of individual RF channels based on relative B1+ phase maps rapidly obtained in vivo for each channel of an eight‐element stripline coil. The relative transmit phases needed to maximize B1+ coherence within a limited region around the prostate greatly differed from those dictated by coil geometry and were highly subject‐dependent. A set of transmit phases determined by B1+ shimming provided a gain in transmit efficiency of 4.2 ± 2.7 in the prostate when compared to the standard transmit phases determined by coil geometry. This increased efficiency resulted in large reductions in required RF power for a given flip angle in the prostate which, when accounted for in modeling studies, resulted in significant reductions of local specific absorption rates. Additionally, B1+ shimming decreased B1+ nonuniformity within the prostate from (24 ± 9%) to (5 ± 4%). This study demonstrates the tremendous impact of fast local B1+ phase shimming on ultrahigh magnetic field body imaging. Magn Reson Med 59:396–409, 2008.
17 February 2016 in Magnetic Resonance in Medicine
ARAlexander J.E. Raaijmakers
Alexander J.E. Raaijmakers
18 December 2008 in Magnetic Resonance in Medicine
This work reports preliminary results from the first human cardiac imaging at 7 Tesla (T). Images were acquired using an eight‐channel transmission line (TEM) array together with local B1 shimming. The TEM array consisted of anterior and posterior plates closely positioned to the subjects' thorax. The currents in the independent elements of these arrays were phased to promote constructive interference of the complex, short wavelength radio frequency field over the entire heart. Anatomic and functional images were acquired within a single breath hold to reduce respiratory motion artifacts while a vector cardiogram (VCG) was used to mitigate cardiac motion artifacts and gating. SAR exposure was modeled, monitored, and was limited to FDA guidelines for the human torso in subject studies. Preliminary results including short‐axis and four‐chamber VCG‐retrogated FLASH cines, as well as, short‐axis TSE images demonstrate the feasibility of safe and accurate human cardiac imaging at 7T. Magn Reson Med, 2009.