Mehmet Ali Ebeoğlu

Mehmet Ali Ebeoğlu

Auto-generated profile, based on publicly available information

Mehmet Ali Ebeoğlu

Department of Electrical-Electronics Engineering, Dumlupınar University, Kutahya, Türkiye

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2020 in TURKISH JOURNAL OF CHEMISTRY
Verified
Journal Article
Open access
ESEvin Sahin Sadik
Evin Sahin Sadik
HSHamdi Melih Saraoğlu
Hamdi Melih Saraoğlu
IGILKE GUROL
ILKE GUROL
MEMehmet Ali Ebeoğlu
Mehmet Ali Ebeoğlu
FKFatma Emel Koçak
Fatma Emel Koçak
Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Microbalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose/pure water solution tests and human blood serum tests. In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations. In the second stage of the study, human blood serum measurements were performed using QCM to determine blood glucose levels. QCM sensors were coated with phthalocyanines (Pcs) by jet spray method. The blood glucose values of 96 volunteers, which ranged from 71 mg/dL to 329 mg/dL, were recorded. As a result of the study, human glucose values were determined with an average error of 3.25%.

27 August 2025 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
KKKadir Kaya
Kadir Kaya
MEMehmet Ali Ebeoğlu
Mehmet Ali Ebeoğlu
Today, traditional e-nose systems have been replaced by gas detection systems based on micro gas chromatography(µGC). This approach, which is based on the fabrication of components at the micro scale, has the potential to improve the selectivity and sensitivity of e-nose systems. Therefore, the development of high-precision gas sensors integrated with µGC is a critical research topic. In this study, a prototype application of a micro interdigitated electrode (µIDE) gas sensor array integrated onto a µGC system made of silicon material was realized. This integration allowed for the rapid characterization of the uniquely produced µIDE sensor. Additionally, the structure of the µGC system designed with the integrated µIDE sensor has been introduced to the literature. All experimental results in this study were obtained using the µIDE sensor prototype. The fact that the prototype exhibits chemical capacitive behavior similar to that of the original silicon-based µIDE sensor, possesses comparable impedance values at the same frequency, and maintains identical electrode thickness and spacing, reinforces the validity and representativeness of the experimental measurement outcomes. The impedance of the µIDE sensor prototype is approximately 32 kΩ at a frequency of 10 MHz. An AC interface circuit was designed to measure variations in the impedance magnitude and phase angle of the µIDE sensor prototype. To reduce noise in the sensor’s gas measurement signals and to improve measurement performance, a linear Kalman filter was utilized. The gas detection sensitivities of the µIDE sensor prototype were calculated as 0.7517 Ω/ppm for NO₂ (6.7 ppm), 0.0118 Ω/ppm for acetone (3640 ppm), 0.0067 Ω/ppm for ethanol (1820 ppm), and 0.0077 Ω/ppm for chloroform (1465 ppm). This research is a pioneering study in the measurement of air pollutants such as NO₂ gas, as well as other volatile organic compound gases such as acetone, ethanol, and chloroform, using a capacitive sensor.