Gülen Demirpolat

Gülen Demirpolat

Auto-generated profile, based on publicly available information

Gülen Demirpolat

Department of Radiology, Balıkesir University Faculty of Medicine, Balıkesir, Türkiye

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2006 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
GDGulen Demirpolat
Gulen Demirpolat
IOIsmail Oran
Ismail Oran
STSadik Tamsel
Sadik Tamsel
MPMustafa Parildar
Mustafa Parildar
AMAhmet Memis
Ahmet Memis

9 December 2016 in Folia Morphologica
Verified
Journal Article
Closed access
GDG. Demirpolat
G. Demirpolat
EBE. Bulbul
E. Bulbul
BYB. Yanik
B. Yanik
The aim of the study was to evaluate the prevalence and morphometric features of mastoid emissary vein (MEV) on multidetector computed tomography (MDCT) scans, emphasize its clinical significance and review its surgical implications. Cranial and temporal bone MDCTs of 248 patients (496 sides) were analysed by 2 radiologists. Mastoid foramen (MF) was defined on the 3 dimensional volume rendered (3DVR) images. The MF and mastoid emissary canal (MEC) were investigated in axial thin slices and the diameters of the largest MF and MEC were measured. Mean diameters of MF and MEC were determined. The number of the mastoid foramina was noted. Differences in MF prevalence by sex and side were evaluated. The overall prevalence of MEC was 92.3%. It was observed in 91.5% of women and 93.3% of men. MEC was present on the right side in 84.7% and on the left side in 82.3% of temporal bones. The mean diameter of MF was 1.92 ± ± 1.02 mm on the right and 1.84 ± 0.98 mm on the left. In both sides the number of the MF's changed from absent to triple. The mean diameter of MEC was 1.58 ± 0.86 mm on the right and 1.48 ± 0.79 mm on the left side. The mean diameter of MEC was significantly larger in men. No significant correlation was detected between age and the MEC diameter. The preoperative detection of mastoid emissary veins is necessary. The radiologists should be familiar with their clinical significance and variant appearances and report them accurately. Knowledge of their morphology and surgical implications by the surgeons will make them aware to avoid unexpected and fatal complications while operating in the suboccipital and mastoid area. MDCT is a reliable diagnostic tool for imaging the MEC and MF.

1 July 2009 in Acta Radiologica
Verified
Journal Article
Closed access
CAC. Aksu
C. Aksu
GDG. Demirpolat
G. Demirpolat
IOI. Oran
I. Oran
MPM. Parildar
M. Parildar
AMA. Memis
A. Memis
Background: Chronic mesenteric ischemia (CMI) is a life-threatening disorder, which is usually associated with stenosis or occlusion of celiac or mesenteric arteries. Purpose: To review our experience and to assess short-term results of stent placement in stenotic mesenteric arteries. Material and Methods: Primary stent placement was performed in 15 patients who had nausea, vomiting, postprandial pain, and weight loss due to steno-occlusive diseases of mesenteric arteries. After stenting, the patients were followed clinically and with Doppler ultrasound at 1, 6, and 12 months. Symptomatic patients with restenosis were examined with digital subtraction angiography and were referred for retreatment with balloon dilatation. Results: Twenty-three stenoses and 11 occlusions were detected in 15 patients, and 18 stenoses were treated with primary stenting. Single-vessel endovascular treatment was performed in 12 patients. In three patients, two arteries were stented in the same session. Technical success rate was 18/18 (100%). Clinical success was achieved in 13/15 (86.6%) patients. First-month mortality was 13%. During the mean 16.1-month follow-up period, restenoses developed in three patients. One of them was successfully treated with balloon angioplasty. Primary patency was 9/11 (81%) and primary assisted patency was 81% at 12 months. The complication rate was 1/15 patients (0.06%). Conclusion: Our experience suggests that stent placement has a potential role in chronic mesenteric ischemia with low incidence of complications and high technical and clinical success rates.

1 January 2009 in Diagnostic and Interventional Radiology
Verified
Journal Article
Closed access
GDGulen Demirpolat
Gulen Demirpolat
AOAysenur Oktay
Aysenur Oktay
IBIsil Bilgen
Isil Bilgen
HIHasan Isayev
Hasan Isayev
To evaluate the mammographic findings of the sternalis muscle and discuss appropriate diagnostic approaches. Ten years of records from our mammography unit were retrospectively examined for the presence of the sternalis muscle. This variant was seen in 10 women out of the 52,930 examined, and the mammograms of these patients were reevaluated. The size, shape and contours of the muscle were reviewed on the craniocaudal (CC) and mediolateral oblique (MLO) views. Yearly mammograms were assessed to evaluate follow-up changes. Extra examinations were reviewed, including ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI). The prevalence of the sternalis muscle was 0.018%. Its contours were well-defined, irregular or spiculated, and the diameter ranged from 3-4 mm to 15 mm. The shape of the muscle varied from slightly bulging to round or triangular. The muscle was detected on MLO projections in three patients as an inferior soft tissue density at the posterior edge of the breast, continuous with the pectoralis muscle. Distinct pulling of the breast led to variations in the appearance of the muscle on yearly mammograms. US examinations were normal in all patients. CT and MRI showed the muscle clearly. The appearance of the sternalis muscle may vary on CC views. It may also be detected on MLO projections. The ability to visualize the muscle depends on proper positioning. Knowledge of its detectability on mammograms will prevent the misdiagnosis of a mass and prevent further unnecessary investigations.

10 March 2023 in Tuberk Toraks
Verified
Journal Article
Open access
NSNurhan Sarioglu
Nurhan Sarioglu
GAGülden Deniz Aksu
Gülden Deniz Aksu
HÇHikmet Çoban
Hikmet Çoban
EBErdoğan Bülbül
Erdoğan Bülbül
GDGülen Demirpolat
Gülen Demirpolat
FEFuat Erel
Fuat Erel
COVID-19 survivors may take longer to regain full well-being. This study aimed to investigate clinical and functional evaluation and radiologic changes in the third month after COVID-19. A total of 126 patients were assessed in the third month for symptoms, pulmonary function, exercise capacity, radiologic imaging, and quality of life after being discharged following COVID-19 treatment. Two radiologists evaluated the initial and follow-up images. At the third month follow-up visit, the most common persisting symptoms were shortness of breath (32.5%), cough (12.7%), and muscle pain (12.7%). At the follow-up visit, oxygen saturations at rest and after a sixmin walking test were lower in patients with prior intensive care hospitalization compared to those without (p<0.001, p= 0.004). Computed tomography (CT) scans revealed persisting pulmonary pathologies in 64.6% of patients at the third month follow-up. The most common pathologies on follow-up thoracic CT were fibrotic-like changes in 44.2% and ground-glass opacities (GGO) in 33.3%. Regression analysis unveiled that age [95% confidence interval (CI), 1.01 to 1.15; p= 0.020], male sex (95% CI, 4.06 to 95.3, p<0.001), first CT severity score (95% CI, 1.02 to 1.41, p= 0.028), duration of hospitalization (95% CI, 1.02 to 1.18, p= 0.012), oxygen saturation (95% CI, 0.86 to 0.96, p<0.001) were independent predictors of fibrotic-like changes. In the third month following COVID-19, the most common symptom was dyspnea, and the most common radiological findings were fibrotic-like changes and GGO. Longer follow-up studies of COVID-19 survivors are needed to observe lasting changes.

1 January 2010 in Diagnostic and Interventional Radiology
Verified
Journal Article
Closed access
GDGulen Demirpolat
Gulen Demirpolat
MYMurvet Yuksel
Murvet Yuksel
GKGulgun Kavukcu
Gulgun Kavukcu
DTDeniz Tuncel
Deniz Tuncel
To evaluate the differences in image quality of carotid computed tomographic angiography (CTA) of patients injected with contrast material in their right arms versus patients injected with contrast material in their left arms. Patients who had cerebrovascular accidents and subsequently underwent CTA were included in the study. Contrast material was injected into the right arms of 44 patients and into the left arms of 46 patients. Source images of a total of 90 CTAs were retrospectively evaluated for perivenous streak artifacts and contrast material reflux into the veins of the neck and upper thorax. After adjusting for differences in gender, the relationship between the injection site and the intensity of perivenous streak artifacts and venous reflux was determined. Perivenous streak artifacts and venous reflux were demonstrated in patients who underwent either right or left arm injections. However, the intensity of perivenous streak artifacts was stronger in patients who were injected with contrast material in the left arm. Venous reflux into the neck and upper thorax veins was also more severe and more frequent with left arm injections. A decreased retrosternal distance facilitated reversed flow into the veins when the left arm injection was used. Perivenous beam hardening streak artifacts and venous reflux could not be prevented with right or left arm injections. However, patients who were injected with contrast material in their right arms showed fewer artifacts, thus allowing for better quality images on CTA.