Eiman Graiz

Eiman Graiz

Auto-generated profile, based on publicly available information

Eiman Graiz

Department of Architecture, Yarmouk University, Irbid, Jordan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in IEEE Access
Verified
Journal Article
Open access
EGEiman Graiz
Eiman Graiz
Wael Waleed Al-AzhariWael Waleed Al-Azhari
Wael Waleed Al-Azhari
This paper deals with energy efficient glass in office buildings in Amman city. The objectives of this study are to understand the role of efficient glass in reducing lighting, heating, and cooling demands and the amount savings to achieve. In addition, to suggest main guidelines to follow when designing glazed office buildings for architects and stakeholders. Evaluation of thermal and daylighting performances for a glazed building in Amman was performed by Ecotect and some equations. The reductions in lighting, heating, and cooling loads and energy cost were evaluated through a comparative simulation among three glass types considering four optical and thermal variables; U-Value, Visual Light Transmission (VLT), Solar Heat Gain Coefficient (SHGC), and Solar Coefficient (SC). Results show that the basic factors to enhance buildings energy behavior are: building location and the availability of the solar radiation at the selected location. In addition to the building orientation and glass optical and thermal properties. The energy efficiency of buildings increase when the building orientation is between 125°- 235°, and the installed glass has U-Value less than 1.5 Wm2/k, VLT between (20-50)%, SHGC and SC less than 0.2. The implementation of these properties reduced the building electricity cost for lighting, heating, and cooling by (45-53)%.