25 April 2018 in Scientific Reports
A lancet-free, label-free biosensor for simultaneous detection of sweat glucose and alcohol was demonstrated using zinc oxide thin films integrated into a nanoporous flexible electrode system. Sensing was achieved from perspired human sweat at low volumes (1–3 μL), comparable to ambient conditions without external stimulation. Zinc oxide thin film electrodes were surface functionalized with alcohol oxidase enzyme and with glucose oxidase enzyme towards developing an affinity biosensor specific to the physiological relevant range of alcohol comprising of 0–2 drinks (0–50 mg/dl) and physiologically relevant range of glucose ranging from hypo- to hyper-glycaemia (50–130 mg/dl) in perspired human sweat. Sensing was achieved by measuring impedance changes associated with alcohol and glucose binding onto the sensor interface using electrochemical impedance spectroscopy with a dynamic range from 0.01–200 mg/dl and a limit of detection of 0.01 mg/dl for alcohol in human sweat. Sensor calibration in synthetic sweat containing interferents (25–200 mg/dl) and comparison using regression and Bland-Altman analysis of sweat sensor performance was done with BACtrack®. Combinatorial detection of glucose and ethanol in perspired human sweat and comparison of sweat sensor performance with Accu-Chek® blood glucose monitoring system that we expect would be relevant for pre-diabetics and diabetics for monitoring their glucose levels and alcohol consumption.
1 October 2018 in Biosensors and Bioelectronics
1 March 2013 in Biomicrofluidics
The instrument described here is an all-electronic dielectrophoresis (DEP) cytometer sensitive to changes in polarizability of single cells. The important novel feature of this work is the differential electrode array that allows independent detection and actuation of single cells within a short section (∼300 μm) of the microfluidic channel. DEP actuation modifies the altitude of the cells flowing between two altitude detection sites in proportion to cell polarizability; changes in altitude smaller than 0.25 μm can be detected electronically. Analysis of individual experimental signatures allows us to make a simple connection between the Clausius-Mossotti factor (CMF) and the amount of vertical cell deflection during actuation. This results in an all-electronic, label-free differential detector that monitors changes in physiological properties of the living cells and can be fully automated and miniaturized in order to be used in various online and offline probes and point-of-care medical applications. High sensitivity of the DEP cytometer facilitates observations of delicate changes in cell polarization that occur at the onset of apoptosis. We illustrate the application of this concept on a population of Chinese hamster ovary (CHO) cells that were followed in their rapid transition from a healthy viable to an early apoptotic state. DEP cytometer viability estimates closely match an Annexin V assay (an early apoptosis marker) on the same population of cells.
17 March 2018 in ECS Journal of Solid State Science and Technology
Humidity sensing is critical in environmental and industrial spaces to monitor air conditions for the wellbeing of the human population and to ensure favorable industrial processes such as storage and performance. In this work, we utilize room temperature ionic liquids (RTILs) as novel sensing elements toward the development of a robust electrochemical humidity sensor for integration in semiconductor technology. For this study, we report and discuss the performances of a non-fluorinated RTIL vis-a-vis a fluorinated RTIL, MMIM[MeSO4] and EMIM[TF2N], on exposure to humidity levels 25–65%RH at low (25–45°C) and elevated temperatures (65°C). The electrochemical responses of the RTILs to humidity and temperature are recorded via electrochemical impedance spectroscopy to measure the capacitance changes occurring within the electrochemical double layer. Both RTILs show similar responses to humidity levels and temperatures. This work is the first demonstration of the implementation of RTILs on micro electronic devices toward achieving rapid and sensitive humidity sensing.
19 June 2018 in ECS Transactions
Rising environmental concerns have led to the development of sensors to monitor environmental conditions such as CO2 and relative humidity (RH). Requirement of sensor performance metrics such as low power, high stability, increased sensitivity has led to the investigation of RTIL as a suitable candidate for environmental sensing. A versatile, robust electrochemical duplex sensor for the detection of CO2 and humidity using a novel sensing material – Room temperature ionic liquid (RTIL) is presented. RTILs interfaced with a sensing electrode platform results in the formation of multiple electrochemical double layers (EDL). AC perturbation of the system causes charge redistribution in the EDL because of CO2 and water adsorption which is studied through an AC based technique- Electrochemical impedance spectroscopy. The frequency response of the EDL provides an insight of the impedance changes of the EDL as the environment changes around them. The effects of CO2 concentrations and RH levels across temperatures on three RTILs - MMIM [MeSO4], EMIM[TF2N] and EMIM[FAP] have been investigated. Furthermore, the adsorption/desorption dynamics of the best performing RTILs were evaluated to understand the repeatability in CO2 sensing behavior. RTILs have the potential to be integrated with semiconductor technology for the sensitive detection of CO2 concentrations and humidity ranges across varying temperatures. Hence, it has the potential of a new strategy for achieving low power environmental sensors.