1 October 2018 in Polymer
1 October 2012 in Microscopy and Microanalysis
A method for obtaining quantitative mean atomic number images in a scanning electron microscope for different kinds of samples has been developed. The backscattered electron signal is monotonically increasing with the mean atomic number Z, and accordingly Z can be given as a function of the image gray levels. From results obtained from Monte Carlo simulations, an exponential function is fitted to convert the backscattered registered gray levels into a Z image map. Once this fitting was performed, the reproducibility of the Z determination was checked through the acquisition of backscattered electron images from metal and mineral standards. The developed method can be applied to any unknown sample, always controlling the experimental conditions, as shown here for a thin section of a rock in which several unknown mineral phases are present; the results obtained herein are compared to quantitative assessments performed with X-ray spectra from each mineral phase.
31 January 2008 in Spectrochimica Acta Part B: Atomic Spectroscopy
20 November 2018 in Journal of Analytical Atomic Spectrometry
Sulfur samples in different oxidation states (+4, +6, 0 and −2) were irradiated in a commercial microscope, acquiring Kα and Kβ spectra in order to investigate the influence of the chemical bond on the occurrence of different sulfur decays to 1s vacancy states.
13 December 2016 in Journal of Analytical Atomic Spectrometry
Diagram and satellite line parameters were obtained from Fe-L and Ni-L X-ray spectra induced by electron impact.