Dean Chen

Dean Chen

Auto-generated profile, based on publicly available information

Dean Chen

Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, Los Angeles, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2023 in Composites Part B: Engineering
Verified
Journal Article
Open access
YXYuhai Xiang
Yuhai Xiang
DCDean Chen
Dean Chen
NANitesh Arora
Nitesh Arora
QYQi Yao
Qi Yao
Stephan RudykhStephan Rudykh
Stephan Rudykh

22 April 2026 in Nature Communications
Verified
Journal Article
Open access
PDF file
DCDean Chen
Dean Chen
NANitesh Arora
Nitesh Arora
YXYuhai Xiang
Yuhai Xiang
QYQi Yao
Qi Yao
QZQuan Zhang
Quan Zhang
Stephan RudykhStephan Rudykh
Stephan Rudykh
We report the experimental observations of large-scale pattern formation in soft quasicrystals activated by mechanical loading. The soft material system utilizes localized transformations to give rise to large-scale organized patterns. The complex multiscale mechanisms lead to an initial loss of microscale quasicrystalline order, which ultimately reemerges in the large-scale patterns with rotational symmetry. Our experiments demonstrate that the resulting large-scale patterns can be pre-designed by fine-tuning initial local chirality and porosity at small length scales. Furthermore, different initial configurations result in patterns exhibiting high shape similarity, with characteristic lengths falling within a discrete sequence governed by the silver ratio. This experimentally observed phenomenon opens a new class of transformative materials with switchable self-similarity propagating across length scales.

8 July 2025 in Research Square
Verified
Preprint
Open access
PDF file
Stephan RudykhStephan Rudykh
Stephan Rudykh
DCDean Chen
Dean Chen
NANitesh Arora
Nitesh Arora
YXYuhai Xiang
Yuhai Xiang
QYQi Yao
Qi Yao
QZQuan Zhang
Quan Zhang
We report the experimental observations of large-scale pattern formation in soft quasicrystals activated by mechanical loading. The soft material system utilizes localized transformations to give rise to large-scale organized patterns. The complex multiscale mechanisms lead to an initial loss of microscale quasi-crystalline order, which ultimately reemerges in the large-scale patterns with rotational symmetry. Our experiments demonstrate that the resulting large-scale patterns can be pre-designed by fine-tuning initial local chirality at small length scales. Furthermore, different initial configurations result in patterns exhibiting high shape similarity, with characteristic lengths falling within a discrete sequence governed by the silver ratio. This experimentally observed phenomenon opens a new class of transformative materials with switchable self-similarity propagating across length scales.

2 March 2026 in International Journal of Solids and Structures
Verified
Journal Article
Open access
JTJanhavi Tarale
Janhavi Tarale
DCDean Chen
Dean Chen
NANitesh Arora
Nitesh Arora
Stephan RudykhStephan Rudykh
Stephan Rudykh

7 August 2025 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
APArmin W. Pomeroy
Armin W. Pomeroy
AUAlexander Upfill-Brown
Alexander Upfill-Brown
BPBrandon T. Peterson
Brandon T. Peterson
DCDean Chen
Dean Chen
JWJoel Weisenburger
Joel Weisenburger
TCTyler R. Clites
Tyler R. Clites
Objective: Total knee arthroplasty (TKA) is a common and highly successful treatment for knee osteoarthritis. Despite its success, some TKA implants still do not last the remaining lifetime of the patient, due in large part to aseptic loosening of the bone-implant interface, most commonly involving the tibial component. In this manuscript, we present a compliant tibial stem with the potential to increase the lifespan of TKA by accommodating rotation of the tibial tray about the tibia’s long axis without introducing an additional high-cycle-count wear surface. Our objective was to refine the design of this implant to support the loads and displacements associated with common activities of daily living (ADLs), and to validate performance of a physical prototype on the benchtop. Methods: We used finite element analysis to sweep a representative parameter space of reasonably-sized caged hinges, and then to refine the mechanism geometry in the context of in vivo knee joint loads. We fabricated a prototype of the refined mechanism, and evaluated performance of that physical prototype under ADL loads and displacements. Results: The refined mechanism supports walking loads and displacements with a safety factor of 1.47 on the target fatigue stress limit. The maximum reaction moment in the prototype was 1.22 Nm during emulated walking, which represents a reduction of approximately 80% from the in vivo reaction moment within a conventional TKA implant rotating to the same angle. Discussion/Conclusion: Our results demonstrate feasibility of a compliant tibial stem with the potential to decrease failure rates and increase longevity of TKA implants.