Takehito Hirose

Takehito Hirose

Auto-generated profile, based on publicly available information

Takehito Hirose

Department of Orthopaedic Surgery, The University of Osaka Graduate School of Medicine, Osaka, Japan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2021 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
SNShigeto Nakagawa
Shigeto Nakagawa
THTakehito Hirose
Takehito Hirose
RURyohei Uchida
Ryohei Uchida
TOTomoki Ohori
Tomoki Ohori
TMTatsuo Mae
Tatsuo Mae
A preoperative glenoid defect of 13.5% or larger is recognized as a subcritical glenoid defect at arthroscopic Bankart repair (ABR) for collision/contact athletes or military personnel. To clarify the prevalence and size of remaining bone fragments in shoulders with a subcritical glenoid defect at recurrent anterior instability and to investigate the influence on postoperative recurrence after ABR for younger competitive athletes. Cohort study; Level of evidence, 4. The study included 96 shoulders with recurrent instability that underwent ABR between July 2011 and March 2018 for shoulders with a subcritical glenoid defect. The patients were divided into 2 groups according to the glenoid defect size (13.5%-0%-<5%; medium, 5%-<10%; large, ≥10%). The postoperative recurrence rate for each combination of glenoid defect size and bone fragment size was investigated for competitive athletes aged <30 years. The fragments, when present, were repaired to the glenoid. The glenoid defect size was 13.5%-<20% in 60 shoulders (medium defect group) and ≥20% in 36 shoulders (large defect group). The mean bone fragment size was 6.7% ± 5.1% and 8.9% ± 4.9%, respectively (P = .042). In the medium defect group, there were 15 shoulders (25%) without a bone fragment, 6 shoulders (10%) with a small fragment, 23 shoulders (38.3%) with a medium fragment, and 16 shoulders (26.7%) with a large fragment. In the large defect group, the respective numbers were 2 shoulders (5.6%), 6 shoulders (16.7%), 14 shoulders (38.9%), and 14 shoulders (38.9%). A medium or large bone fragment was more common in the large defect group (P = .252). Among 64 younger competitive athletes who underwent ABR with a minimum of 2 years of follow-up, postoperative recurrence was recognized in 7 of 38 (18.4%) athletes in the medium defect group, but it was not recognized in any of the 26 athletes in the large defect group (P = .036). Postoperative recurrence was recognized in 4 of 12 (33.3%) athletes with a small fragment or no fragment and in 3 of 52 (5.8%) athletes with a medium or large fragment (P = .019). A larger bone fragment frequently remained in shoulders with a subcritical glenoid defect at recurrent instability. The postoperative recurrence rate after ABR for younger competitive athletes was low when a remaining larger bone fragment was repaired.

13 April 2022 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
THTakehito Hirose
Takehito Hirose
TMTatsuo Mae
Tatsuo Mae
IOIssei Ogasawara
Issei Ogasawara
SYSatoshi Yamakawa
Satoshi Yamakawa
KNKen Nakata
Ken Nakata
SOSeiji Okada
Seiji Okada
Background: Meniscal extrusion/translation has been used as an index for meniscal treatment. However, the relationship between meniscal displacement and the degree of meniscal tear or load–transmission function of the lateral meniscus (LM) remains unclear. Purpose: To clarify the relationship between the width of the radial tear of the LM and (1) meniscal displacement or (2) resultant force through the meniscus under axial compressive load in the porcine model. Study Design: Controlled laboratory study. Methods: Eight intact porcine knees with or without a partial radial tear at the midbody of the LM (involving 30%, 60%, or 90% of its width) were investigated. Reflective markers were attached to the outer wall of the anterior, anteromiddle, posteromiddle, and posterior segments of the LM. A 300-N axial load was applied at 2 flexion angles (30° and 60°), and the 3–dimensional forces and trajectories of the knees were recorded. Marker movements were simultaneously tracked using a motion capture camera system. After total meniscectomy of the LM, the recorded knee trajectories were reproduced, and the resultant force through the LM was calculated (a force carried only by the meniscus in response to a load applied to the whole knee joint). Results: At both flexion angles, the change in distance (mean ± SD) between the anterior and posterior markers under load increased significantly more in the anteroposterior direction in LMs with a 90% tear than in intact LMs (30°, 0.4 ± 0.3 vs 1.4 ± 0.8 mm, P = .004; 60°, 0.1 ± 0.7 vs 1.4 ± 1.0 mm, P < .001 [intact vs 90% tear]). The change in distance between the anteromiddle and posteromiddle markers at 30° also significantly increased in LMs with a 90% tear (0.2 ± 0.2 vs 1.3 ± 1.2 mm, P = .02 [intact vs 90% tear]). The resultant force was significantly lower in LMs with a 90% tear than in intact LMs (30°, 125 ± 47 vs 48 ± 20 N, P < .001; 60°, 93 ± 46 vs 43 ± 11 N, P = .002 [intact vs 90% tear]). We found no significant differences in either meniscal displacements or resultant forces between intact LMs and those with 30% or 60% tears. Conclusion: LMs with a 90%-width midbody radial tear lost load–transmission function with their displacement relative to the tibia primarily in the anteroposterior direction in the porcine model. Clinical Relevance: Even 1 mm of displacement after meniscal injury is evidence that the load–transmission function of the meniscus is greatly impaired. When a displaced torn LM is diagnosed in preoperative imaging, meniscal repair surgery should be considered.


27 December 2022 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
SNShigeto Nakagawa
Shigeto Nakagawa
THTakehito Hirose
Takehito Hirose
TTToshitaka Tsunematsu
Toshitaka Tsunematsu
Tomoki OhoriTomoki Ohori
Tomoki Ohori
HYHiroyuki Yokoi
Hiroyuki Yokoi
MYMinoru Yoneda
Minoru Yoneda

21 December 2022 in JSES International
Verified
Journal Article
Open access
SNShigeto Nakagawa
Shigeto Nakagawa
THTakehito Hirose
Takehito Hirose
RURyohei Uchida
Ryohei Uchida
HNHiroyuki Nakamura
Hiroyuki Nakamura
TMTatsuo Mae
Tatsuo Mae
MYMinoru Yoneda
Minoru Yoneda
With recurrent anterior instability the bone fragment of a bony Bankart lesion is often small compared to the glenoid defect. The purpose of the present study was to clarify the changes to both the bone fragment and glenoid defect over time in a single subject. Participants were patients who underwent computed tomography (CT) at least twice after an instability event between 2004 and 2021 and had a fragment-type glenoid at first CT. The glenoid rim width (A), glenoid defect width (B), and bone fragment width (C) were measured in millimeters. If B or C increased by 1 mm or more from the first to final CT, the change was judged as "enlarged," and if B or C decreased by 1 mm or more, it was judged as "reduced"; all other cases were judged as "similar." Then, glenoid defect size and bone fragment size were calculated as B/A×100% and C/A×100%, respectively, and the changes from the first to final CT were compared. From the first to final CT, the glenoid defect was enlarged in 30 shoulders, similar in 13 shoulders, and reduced in 4 shoulders, and the bone fragment was enlarged in 18 shoulders, similar in 24 shoulders, and reduced in 5 shoulders. The mean glenoid defect size significantly increased from 10.9% to 15.3% (P < .001), and the mean bone fragment size increased from 6.4% to 7.8%, respectively (P = .005). At the final CT, in 6 shoulders a new glenoid fracture was observed at a different site from the original fracture. When they were excluded from the analyses, the mean glenoid defect size still significantly increased (from 11.2% to 15.2%; P < .001), but the mean bone fragment size did not (6.5% vs. 7.3%, respectively; P = .088). In shoulders with recurrent anterior instability, glenoid defect size appears to increase significantly over time, whereas the bone fragment size remains unchanged or increases only slightly. Bone fragment resorption is quite rare, and a bone fragment appears to be small because of an enlarged glenoid defect.

25 July 2019 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
PDF file
TMTatsuo Mae
Tatsuo Mae
KNKen Nakata
Ken Nakata
TKTsukasa Kumai
Tsukasa Kumai
YIYasuyuki Ishibashi
Yasuyuki Ishibashi
TSTomoyuki Suzuki
Tomoyuki Suzuki
HYHideki Yoshikawa
Hideki Yoshikawa
Ultrasonic (US) devices are used in laparoscopic, dental, and spinal surgeries, while it is difficult to use for the joint under irrigation and perfusion solutions due to lack of power. A new US device is developed with greater voltage improvement and has been implemented in the arthroscopic field. The aim is to compare the characteristics of the US devices with the conventional ones in water. Twenty bone blocks from the porcine femur were settled in a holder in water. A 4.0 mm diameter abrader burr moved 15 mm along the long axis of the bone block in ten blocks for three times. A 4.3 mm wide curette blade powered by ultrasonic vibration was moved in the same manner in the other ten blocks. The gutter shape, including the gutter depth and the bottom angle of the gutter, and the curetted area ratio of the gutter were assessed. Forty bones blocks from the porcine femurs were clamped with a holder in water, while the cortical bone surface must be located on the side. A 5 mm diameter drill excavated the bone along the previously-inserted guide wire to the 15 mm depth for twenty blocks. Next, the US excavation probe of 5x4mm rectangular shape was moved to the same depth in the other twenty blocks. Each ten block was cut in half along the bone tunnel and was assessed the surface roughness at three area, while the cross-sectional area (CSA) of the tunnel were measured and the ratio of the measured CSA was calculated based on an expected CSA in the remaining ten blocks for each device. The depth of curettage and bottom angle were significantly smaller with the US device than with the abrader burr at all planes, while the curetted area ratio created by each device was mostly equal to the other. Surface roughness was similar in two evacuating devices except one area. CSA ratio with the US excavation device was significantly smaller than that with the drill. US curettage has an advantage to flatly curette bone surfaces, while a bone tunnel can be accurately created with the US device.