3 July 2024 in Optics Express
Imaging with single-pixel detectors offers a valuable alternative to the conventional focal plane array strategy, especially for wavelengths where silicon-based sensor arrays exhibit lower efficiency. However, the absence of optical sectioning remains a challenge in single-pixel microscopy. In this paper, we introduce a single-pixel microscope with optical sectioning capabilities by integrating single-pixel imaging (SPI) techniques with structured illumination microscopy (SIM) methods. A spatial light modulator positioned at the microscope's input port encodes a series of structured light patterns, which the microscope focuses onto a specific plane of the 3D sample. Simultaneously, a highly sensitive bucket detector captures the light reflected by the object. Optical sectioning is achieved through a high-frequency grating positioned at the microscope's output port, which is conjugated with the spatial light modulator. Utilizing SPI reconstruction techniques and SIM algorithms, our computational microscope produces high-quality 2D images without blurred out-of-focus regions. We validate the performance of the single-pixel microscope (SPM) by measuring the axial response function and acquiring images of various 3D samples in reflected bright-field configuration. Furthermore, we demonstrate the suitability of the optical setup for single-pixel fluorescence microscopy with optical sectioning.
10 May 2025 in Optics & Laser Technology
10 December 2024 in Applied Optics
In this manuscript, two diffraction-based methods for calibrating liquid crystal spatial light modulators are demonstrated theoretically and experimentally. They rely on the coherent interference of two uniform waves whose complex functions are encoded in a single-phase diffractive optical element by using the double-phase method. The interference pattern, recorded in the output plane of a spatially filtered 4f optical imaging system, allows calibration curves to be determined by post-processing. With these methods, both global and local phase calibrations can be performed, allowing inhomogeneous phase responses in liquid crystal displays to be evaluated and tested in a variety of experimental scenarios, such as multiwavelength illumination or varying incidence angles.
15 May 2025 in Optics Express
Optical scanning holography (OSH) can measure three-dimensional (3D) fluorescence targets by recording incoherent holograms with two-dimensional Fresnel zone pattern (FZP) scanning and a single-pixel detector. However, the complexity of the optical setup has limited its applicability. Computational OSH (COSH) has been proposed as a solution to this problem and has shown to be feasible with optical applications such as ghost imaging or Hadamard transform single-pixel imaging. However, the problem with FZP’s scanning speed has limited its ability to visualize dynamic objects. In this study, dynamic objects were visualized using a high-speed digital micromirror device (DMD). In addition, a microscope based on COSH was constructed and then applied to capture moving images of dynamic objects behind dynamic scatterers. The experimental results show that the proposed method captures incoherent holograms with a frame rate of 1.387 Hz using a single-pixel detector. Moreover, numerical simulations indicate that the proposed method achieves imaging with a frame rate of approximately 28 Hz by using random sparse sampling and compressive sensing-based reconstruction.
24 October 2025 in Optics Express
Optical microscopy is constrained by the diffraction limit, restricting spatial resolution in biomedical and engineering imaging applications. While structured illumination microscopy (SIM), together with other techniques, has extended resolution in several optical microscopy techniques, it has not been adapted to single-pixel microscopy (SPM). In this work, we introduce a super resolution SPM (SR-SPM) approach by combining SIM principles with SPM using what we believe to be novel structured sampling patterns (SSPs). SSPs are generated by combining Walsh-Hadamard patterns and fringe patterns with multiple phase shifts and orientations. They are projected onto the sample using a high-speed digital micromirror device (DMD). Sequential measurements are captured by a single-pixel detector and reconstructed through SPI and SIM algorithms to enhance spatial resolution. Experimental validation demonstrates a significant resolution improvement, increasing the modulation transfer function (MTF) spatial frequency limit from 1000 lp/mm to 1500 lp/mm. Results in brightfield and fluorescence imaging confirm enhanced resolution and finer feature differentiation in biological samples, such as quantum-dot-labelled epithelial cells and fluorescent microspheres. The proposed SR-SPM system offers a cost-effective, efficient method for achieving enhanced-resolution, paving the way for broader applications of single-pixel imaging in complex and spectrally challenging environments.
21 January 2026 in Optics & Laser Technology