5 August 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Functional rehabilitation of patients with spinal cord injury remains a current challenge. Training these patients to successfully stand is the first step towards restoring advanced skills such as walking. To address this need, we have developed a novel robotic stand trainer that can apply controlled forces on the trunk and the pelvis of a user, while controlling the knee angle. The stand trainer utilizes cables to apply assistive, resistive, or perturbation forces at the trunk, pelvis, and the knees, simultaneously. We have conducted a human study to validate the system. In this study, we applied multi-direction perturbation forces either at the pelvis or the trunk while assist-as-needed forces were applied to the other segment to keep balance. This study characterizes the human kinematics and measures of balance under the perturbations and assistive forces on the human body. Results shows that the level of force-field assistance (trunk or pelvis) directly affects the motion of the trunk, pelvis, and center of pressure. This provides a quantitative framework to restore balance in patients while providing assistance only when needed. This stand trainer can potentially free up therapists to attend to higher level rehabilitation goals and objectively assist patients to engage in interventions that challenge both their musculoskeletal and sensorimotor impairments.
28 January 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Seated postural abilities are critical to functional independence and participation in children with cerebral palsy, Gross Motor Functional Classification System (GMFCS) levels III-IV. In this proof-of-concept study, we investigated the feasibility of a motor learning-based seated postural training with a robotic Trunk-Support-Trainer (TruST) in a longitudinal single-subject-design (13y, GMFCS IV), and its potential effectiveness in a group of 3 children (6-14y, GMFCS III-IV). TruST is a motorized-cable driven belt placed on the child's trunk to exert active-assistive forces when the trunk moves beyond stability limits. TruST-intervention addresses postural-task progression by tailoring the assistive-force fields to the child's sitting balance to train trunk control during independent short-sitting posture. TruST-intervention consisted of 2 training blocks of six 2hour-sessions per block (3 sessions per week). Pelvic strapping was required in the 1 st block to prevent falls. As primary outcomes, we used the modified functional reach test, gross motor function measure-item set (GMFM-IS), Box & Blocks, and postural kinematics. After TruST-intervention children did not require pelvic strapping to prevent a fall, improved trunk stability during reaching (baseline = 5.49cm, 1week post-training = 16.38cm, 3mos follow-up = 14.63cm, ${P} <; 0.001$ ) and increased their sitting workspace (baseline = 127.55cm 2 , 1week post-training, = 409.92cm 2 , 3mos follow-up = 270.03cm 2 , ${P} <; 0.001$ ). Three children also improved in the GMFM-IS. In summary, our novel robotic TruST-intervention is feasible and can effectively maximize functional independent sitting in children with CP GMFCS III-IV.
6 January 2020 in Spinal Cord Series and Cases
15 July 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
In people with severe neuromotor deficits of trunk and lower extremities, regaining balance in standing is often performed in rehabilitation with manual assistance, rigid body supports or by the use of handrails. To investigate and further expand postural control training in standing, we developed a Robotic Upright Stand Trainer (RobUST). In this study, we used RobUST to deliver trunk perturbations while simultaneously providing postural assistive forces on the pelvis in 10 able-bodied adults. Posture control responses with 'pelvic support' was then compared to 'no support' and 'hand supported' standing, with and without assistance from RobUST. We characterize postural imbalance with kinematic displacements and center of pressure (COP) outcomes, such as amplitude and root mean square of the excursions of COP. Surface electromyography (sEMG) was also applied to investigate muscle control. We additionally investigated ground reaction and handrail forces during standing to analyze how postural strategies and muscle mechanisms with 'pelvic support' via RobUST would differ from standing with 'no support' and with the 'handrail support'. Our results show that during perturbations, pelvic assistive support decreased kinematic and COP excursions compared to standing with no support. The pelvic assistance from RobUST showed similar level of COP changes as the use of handrail support but without reducing muscle activity or ground reaction forces. As expected, the maximum level of postural stability was observed when participants used the handrail and received pelvic assistive forces. In conclusion, RobUST demonstrates potential as a training device since it enhances postural balance without significantly removing muscular control mechanisms that are of interest in re-training postural control strategies in standing.
7 October 2021 in Spinal Cord Series and Cases
10 June 2022 in IEEE Robotics and Automation Letters
Moving from a seated position to a standing position is essential for performing daily functional tasks. However, a sit-to-stand task may lead to falls in people with neuromotor disorders. Previous studies have shown that perturbation-based training can improve individuals’ reactive control and reduce the risk of falls. However, few studies have investigated individuals’ reactive control while transitioning from sit-to-stand. The present study aims to understand how ten healthy adults react to physical perturbations when transitioning from sitting to standing. We delivered two types of perturbations to the participants. In one condition, we used a cable-driven robotic system to displace the user’s pelvis. In the second condition, we used a treadmill to displace the participants’ support surface. A set of perturbations were delivered until participants failed to maintain balance. The type of perturbation delivered, i.e., force applied on the pelvis or displacement of the support surface, was randomized within each set. In addition, the direction of the perturbation, i.e., anterior or posterior, was also randomized within each set. Joint angles, ground reaction forces, and muscle activity using surface electromyography were measured to characterize their balance control strategies. Our results show that perturbation directions had the most distinguishable change among participants. Participants also required an increase in trunk movement to stabilize as the perturbation intensities increased. These results provide important insights for designing future sit-to-stand perturbation-based training in individuals prone to falling.