Chunyan Wu

Chunyan Wu

Auto-generated profile, based on publicly available information

Chunyan Wu

Department of Neurobiology and Behavior, Cornell University, Ithaca, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2020 in eLife
Verified
Journal Article
Open access
TWTianyu Wang
Tianyu Wang
CWChunyan Wu
Chunyan Wu
DODimitre G Ouzounov
Dimitre G Ouzounov
WGWenchao Gu
Wenchao Gu
FXFei Xia
Fei Xia
CXChris Xu
Chris Xu
1300 nm three-photon calcium imaging has emerged as a useful technique to allow calcium imaging in deep brain regions. Application to large-scale neural activity imaging entails a careful balance between recording fidelity and perturbation to the sample. We calculated and experimentally verified the excitation pulse energy to achieve the minimum photon count required for the detection of calcium transients in GCaMP6s-expressing neurons for 920 nm two-photon and 1320 nm three-photon excitation. By considering the combined effects of in-focus signal attenuation and out-of-focus background generation, we quantified the cross-over depth beyond which three-photon microscopy outpeforms two-photon microscopy in recording fidelity. Brain tissue heating by continuous three-photon imaging was simulated with Monte Carlo method and experimentally validated with immunohistochemistry. Increased immunoreactivity was observed with 150 mW excitation power at 1 and 1.2 mm imaging depths. Our analysis presents a translatable model for the optimization of three-photon calcium imaging based on experimentally tractable parameters.

19 February 2024 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
WGWenchao Gu
Wenchao Gu
SLSijin Luozhong
Sijin Luozhong
SCSimian Cai
Simian Cai
KLKetaki Londhe
Ketaki Londhe
NENadine Elkasri
Nadine Elkasri
SJShaoyi Jiang
Shaoyi Jiang

12 June 2020 in Journal of Microelectromechanical Systems
Verified
Journal Article
Open access
SLSunwoo Lee
Sunwoo Lee
ACAlejandro Javier Cortese
Alejandro Javier Cortese
AMAaron Mok
Aaron Mok
CWChunyan Wu
Chunyan Wu
TWTianyu Wang
Tianyu Wang
AMAlyosha Christopher Molnar
Alyosha Christopher Molnar
In vivo, chronic neural recording is critical to understand the nervous system, while a tetherless, miniaturized recording unit can render such recording minimally invasive. We present a tetherless, injectable micro-scale opto-electronically transduced electrode (MOTE) that is ~60μm x 30μm x 330μm, the smallest neural recording unit to date. The MOTE consists of an AlGaAs micro-scale light emitting diode (μLED) heterogeneously integrated on top of conventional 180nm complementary metal-oxide-semiconductor (CMOS) circuit. The MOTE combines the merits of optics (AlGaAs μLED for power and data uplink), and of electronics (CMOS for signal amplification and encoding). The optical powering and communication enable the extreme scaling while the electrical circuits provide a high temporal resolution (<100μs). This paper elaborates on the heterogeneous integration in MOTEs, a topic that has been touted without much demonstration on feasibility or scalability. Based on photolithography, we demonstrate how to build heterogenous systems that are scalable as well as biologically stable - the MOTEs can function in saline water for more than six months, and in a mouse brain for two months (and counting). We also present handling/insertion techniques for users (i.e. biologists) to deploy MOTEs with little or no extra training. [2020-0080]

21 December 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
AMAaron T. Mok
Aaron T. Mok
JSJamien Shea
Jamien Shea
CWChunyan Wu
Chunyan Wu
FXFei Xia
Fei Xia
RTRose Tatarsky
Rose Tatarsky
CXChris Xu
Chris Xu
We built a simple and versatile setup to measure tissue ballistic and total transmission with customizable wavelength range, spatial resolution, and sample sizes. We performed ballistic transmission and total transmission measurements of overlying structures from biological samples ex vivo. We obtained spatially resolved transmission maps to reveal transmission heterogeneity from five microscale tissue samples: Danionella skin, mouse skull bone, mosquito cuticle, wasp cuticle, and rat dura over a wide spectral range from 450 nm to 1624 nm at a spatial resolution of ∼25 µm for ballistic transmission measurements and ∼50 µm for total transmission measurements. We expect our method can be straightforwardly applied to measuring the transmission of other samples. The measurement results will be valuable for multiphoton microscopy. The total transmission of a sample is important for the collection of multiphoton excited fluorescence and the assessment of laser-induced sample heating. The ballistic transmission determines the excitation power at the focus and hence the fluorescence signal generation. Therefore, knowledge of ballistic transmission, total transmission, and transmission heterogeneity of overlying structures of animals and organs are essential to determine the optimal excitation wavelength and fluorophores for non-invasive multiphoton microscopy.

3 November 2025 in Nature Electronics
Verified
Journal Article
Open access
PDF file
SLSunwoo Lee
Sunwoo Lee
SGShahaboddin Ghajari
Shahaboddin Ghajari
SSSanaz Sadeghi
Sanaz Sadeghi
YZYumin Zheng
Yumin Zheng
HZHind Zahr
Hind Zahr
AMAlyosha C. Molnar
Alyosha C. Molnar
The long-term recording of neural activity could be used to understand complex behaviours and disorders. However, the development of technology capable of such measurements faces a variety of technical challenges, including the relative motion between recording electrodes and tissue and the excessive displaced volume from implanted electronics. Here we report a subnanolitre-volume tetherless optoelectronic microsystem for neural recording. The system relies on light for photovoltaic power and data transfer, through a light-emitting diode, eliminating the need for wires or other tethers. It uses a single AlGaAs diode as both photovoltaic and light-emitting diode. Complementary metal–oxide–semiconductor circuits provide low-noise amplification, pulse-position-modulated encoding and electro-optical transduction. Two-dimensional materials processing techniques, vacuum annealing and atomic layer deposition, in conjunction with a standard complementary metal–oxide–semiconductor fabrication process, provide compact encapsulation against the corrosive conditions of biological media. We show that the subnanolitre neural implant is capable of chronic (365 days) in vivo recordings in awake mice.

18 November 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
TWTianyu Wang
Tianyu Wang
CWChunyan Wu
Chunyan Wu
DODimitre G. Ouzounov
Dimitre G. Ouzounov
WGWenchao Gu
Wenchao Gu
FXFei Xia
Fei Xia
CXChris Xu
Chris Xu
1300-nm three-photon calcium imaging has emerged as a useful technique to allow calcium imaging in deep brain regions. Application to large-scale neural activity imaging entails a careful balance between recording fidelity and tissue heating. We calculated and experimentally verified the excitation pulse energy to achieve the minimum photon count required for the detection of calcium transients in GCaMP6s-expressing neurons for 920-nm two-photon and 1320-nm three-photon excitation, respectively. Brain tissue heating by continuous three-photon imaging was simulated with Monte Carlo method and experimentally validated with immunohistochemistry. We observed increased immunoreactivity with 150 mW excitation power at 1.0- and 1.2-mm imaging depths. Based on the data, we explained how three-photon excitation achieves better calcium imaging fidelity than two-photon excitation in the deep brain and quantified the imaging depth where three-photon microscopy should be applied. Our analysis presents a translatable model for the optimization of three-photon calcium imaging based on experimentally tractable parameters.