John Z. Wu

John Z. Wu

Auto-generated profile, based on publicly available information

John Z. Wu

National Institute for Occupational Safety and Health

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2004 in Medical Engineering & Physics
Verified
Journal Article
Closed access
JWJ.Z. Wu
J.Z. Wu
RDR.G. Dong
R.G. Dong
SRS. Rakheja
S. Rakheja
ASA.W. Schopper
A.W. Schopper
WSW.P. Smutz
W.P. Smutz
Tactile performance of human fingertips is associated with activity of the nerve endings and sensitivity of the soft tissue within the fingertip to the static and dynamic skin indentation. The nerve endings in the fingertips sense the stress/strain states developed within the soft tissue, which are affected by the material properties of the tissues. The vibrotactile sensation and tactile performance are thus believed to be strongly influenced by the nonlinear and time-dependent properties of the soft tissues. The purpose of the present research is to simulate the biomechanics of tactile sensation. A two-dimensional model, which incorporates the essential anatomical structures of a finger (i.e. skin, subcutaneous tissue, bone, and nail), has been used for the analysis. The skin tissue is assumed to be hyperelastic and viscoelastic. The subcutaneous tissue is considered to be a nonlinear, biphasic material composed of a hyperelastic solid and an inviscid fluid phase. The nail and bone are considered to be linearly elastic. The advantages of the proposed fingertip model over the previous "waterbed" and "continuum" fingertip models include its ability to predict the deflection profile of the fingertip surface, the stress and strain distributions within the soft tissue, and most importantly, the dynamic response of the fingertip to mechanical stimuli. The proposed model is applied to simulate the mechanical responses of a fingertip under a line load, and in one-point (1PT) and two-point (2PT) tactile discrimination tests. The model's predictions of the deflection profiles of a fingertip surface under a line load agree well with the reported experimental data. Assuming that the mechanoreceptors in the dermis sense the stimuli associated with normal strains (the vertical and horizontal strains) and strain energy density, our numerical results suggest that the threshold of 2PT discrimination may lie between 2.0 and 3.0 mm, which is consistent with the published experimental data. The present study represents an effort to develop a structural model of the fingertip that incorporates its anatomical structure, and the nonlinear and time-dependent properties of the soft tissues.

1 January 2006 in Journal of Biomechanics
Verified
Journal Article
Closed access
JWJ.Z. Wu
J.Z. Wu
KKK. Krajnak
K. Krajnak
DWD.E. Welcome
D.E. Welcome
RDR.G. Dong
R.G. Dong

1 January 2004 in Journal of Biomechanics
Verified
Journal Article
Closed access
JWJohn Z. Wu
John Z. Wu
RDRen G. Dong
Ren G. Dong
ASAaron W. Schopper
Aaron W. Schopper

1 February 2006 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
JWJohn Z. Wu
John Z. Wu
DWDaniel E. Welcome
Daniel E. Welcome
RDRen G. Dong
Ren G. Dong
The analysis of the mechanics of the contact interactions of fingers/handle and the stress/strain distributions in the soft tissues in the fingertip is essential to optimize design of tools to reduce many occupation-related hand disorders. In the present study, a three-dimensional (3D) finite element (FE) model for the fingertip is proposed to simulate the nonlinear and time-dependent responses of a fingertip to static and dynamic loadings. The proposed FE model incorporates the essential anatomical structures of a finger: skin layers (outer and inner skins), subcutaneous tissue, bone and nail. The soft tissues (inner skin and subcutaneous tissue) are considered to be nonlinearly viscoelastic, while the hard tissues (outer skin, bone and nail) are considered to be linearly elastic. The proposed model has been used to simulate two loading scenarios: (a) the contact interactions between the fingertip and a flat surface and (b) the indentation of the fingerpad via a sharp wedge. For case (a), the predicted force/displacement relationships and time-dependent force responses are compared with the published experimental data; for case (b), the skin surface deflection profiles were predicted and compared with the published experimental observations. Furthermore, for both cases, the time-dependent stress/strain distributions within the tissues of the fingertip were calculated. The good agreement between the model predictions and the experimental observations indicates that the present model is capable of predicting realistic time-dependent force/displacement responses and stress/strain distributions in the soft tissues for dynamic loading conditions.

1 May 2002 in Medical Engineering & Physics
Verified
Journal Article
Closed access
JWJ.Z. Wu
J.Z. Wu
RDR.G. Dong
R.G. Dong
SRS. Rakheja
S. Rakheja
ASA.W. Schopper
A.W. Schopper
Extended exposure to mechanical vibration has been related to many vascular, sensorineural and musculoskeletal disorders of the hand-arm system, frequently termed 'hand-arm vibration syndrome' (HAVS). A two-dimensional, nonlinear finite element model of a fingertip is developed to study the stress and strain fields of the soft tissue under dynamic loading, that may be encountered while grasping and operating a hand-held power tool. The model incorporates the most essential anatomical elements of a fingertip, such as soft tissue, bone, and nail. The finger is assumed to be in contact with a steel plate, simulating the interaction between the fingertip and a vibrating machine tool or handle. The soft tissue is assumed to be nonlinearly visco-elastic, while the nail, bone, and steel plate are considered to be linearly elastic. In order to study the time-dependent deformation behavior of the fingertip, the numerical simulations were performed under ramp-like loading with different ramping periods and sinusoidal vibrations of the contacting plate at three different frequencies (1, 10, and 31.5 Hz). Owing to relatively large deformations of the soft tissue under specified static and dynamic loading, Lagrangian large deformation theory was applied in the present analysis. The effects of the loading rate and the frequency of the sinusoidal vibration on the time-dependent strain/stress distributions in the different depth within the soft tissue of the fingertip are investigated numerically. Our simulations suggest that the soft tissue of the fingertip experiences high local stress and strain under dynamic loading and the fingertip may separate from the vibrating contact surface due to the viscous deformation behaviour of the soft tissue. For a given deformation, the high frequency loading produces a higher stress in the tissues compared to that obtained at a low frequency loading. The present model may serve as a useful tool to study the mechanism of tissue degeneration under vibratory loading encountered during operation of hand-held power tools.

1 March 2002 in Medical Engineering & Physics
Verified
Journal Article
Closed access
JWJ.Z. Wu
J.Z. Wu
Walter HerzogWalter Herzog
Walter Herzog
EHE.M. Hasler
E.M. Hasler
The transplantation of osteochondral (cartilage-bone) plugs is an alternative approach to treat local, full thickness cartilage defects in young patients. It is technically difficult to control the amount of the press fit tolerance and the position of the osteochondral (OC) plug in the recipient hole. Inadequate placement of the OC plugs may produce abnormal stress and strain distributions within the cartilage, and thus influence the regeneration of the injured cartilage site and the maintenance of opposing, healthy cartilage surfaces. In the present study, the influence of press fit tolerance and the placement of the OC plug on the joint contact mechanics was simulated using finite element methods. The joint was assumed to be axi-symmetric with a spherical femur and tibia and a cylindrical OC plug. Our simulations showed that small misplacements of the OC plug induced abnormal tension in the articular cartilage of the opposing, healthy cartilage surface. Such tension might induce unpredictable adaptations, or possibly degenerations, in the opposing cartilage layer. The contact stress profiles in the joint were predicted to change discontinuously across the plug/recipient interface, even when the plug was perfectly placed in the recipient hole, i.e., the plug's surface was aligned with the recipient surface. For a fixed coefficient of friction and a fixed fit tolerance, the maximal sliding force was predicted to vary with the size of the plug and reached a maximum at a specific plug diameter. The present simulations should be helpful for the design of instruments for osteochondral transplantation and placement of OC plugs, for understanding articular cartilage adaptation following osteochondral repair, and for providing insight into the mechanics at the transplant/recipient interface where proper integration of the plug into the joint is most problematic.