Massimiliano Simi

Massimiliano Simi

Auto-generated profile, based on publicly available information

Massimiliano Simi

The BioRobotics Institute, Polo Sant'Anna Valdera, Pisa 56025, Italy

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2013 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
MSMassimiliano Simi
Massimiliano Simi
GGGiada Gerboni
Giada Gerboni
Arianna MenciassiArianna Menciassi
Arianna Menciassi
PVPietro Valdastri
Pietro Valdastri
The authors present a novel magnetomechanical elastic element that can be loaded remotely by varying the magnetic field surrounding it and that is able to store and release mechanical energy upon external triggering. The magnetic torsion spring (MTS) is used as the core component of a self-contained miniature biopsy capsule (9 mm in diameter and 24 mm long) for random tissue sampling in the small bowel. Thanks to the MTS concept, the biopsy mechanism can be loaded wirelessly by a magnetic field applied from outside the body of the patient. At the same time, magnetic coupling guarantees stabilization against the small bowel tissue during sampling. Extreme miniaturization is possible with the proposed approach since no electronics and no power supply are required onboard.

18 January 2012 in Mechanical Sciences
Verified
Journal Article
Open access
PDF file
MSM. Simi
M. Simi
NTN. Tolou
N. Tolou
PVP. Valdastri
P. Valdastri
JHJ. L. Herder
J. L. Herder
AMA. Menciassi
A. Menciassi
PDP. Dario
P. Dario
A novel compliant Magnetic Levitation System (MLS) for a wired miniature surgical camera robot was designed, modeled and fabricated. The robot is composed of two main parts, head and tail, linked by a compliant beam. The tail module embeds two magnets for anchoring and manual rough translation. The head module incorporates two motorized donut-shaped magnets and a miniaturized vision system at the tip. The compliant MLS can exploit the static external magnetic field to induce a smooth bending of the robotic head (0–80°), guaranteeing a wide span tilt motion of the point of view. A nonlinear mathematical model for compliant beam was developed and solved analytically in order to describe and predict the trajectory behaviour of the system for different structural parameters. The entire device is 95 mm long and 12.7 mm in diameter. Use of such a robot in single port or standard multiport laparoscopy could enable a reduction of the number or size of ancillary trocars, or increase the number of working devices that can be deployed, thus paving the way for multiple view point laparoscopy.