Stephanie M. Berg

Stephanie M. Berg

Auto-generated profile, based on publicly available information

Stephanie M. Berg

Environmental Chemistry and Technology Program University of Wisconsin Madison WI USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2020 in Limnology and Oceanography: Methods
Verified
Journal Article
Open access
PDF file
JHJeffrey A. Hawkes
Jeffrey A. Hawkes
JDJuliana D'Andrilli
Juliana D'Andrilli
JAJeffrey N. Agar
Jeffrey N. Agar
MBMark P. Barrow
Mark P. Barrow
SBStephanie M. Berg
Stephanie M. Berg
DPDavid C. Podgorski
David C. Podgorski
High‐resolution mass spectrometry (HRMS) has become a vital tool for dissolved organic matter (DOM) characterization. The upward trend in HRMS analysis of DOM presents challenges in data comparison and interpretation among laboratories operating instruments with differing performance and user operating conditions. It is therefore essential that the community establishes metric ranges and compositional trends for data comparison with reference samples so that data can be robustly compared among research groups. To this end, four identically prepared DOM samples were each measured by 16 laboratories, using 17 commercially purchased instruments, using positive‐ion and negative‐ion mode electrospray ionization (ESI) HRMS analyses. The instruments identified ~1000 common ions in both negative‐ and positive‐ion modes over a wide range of m/z values and chemical space, as determined by van Krevelen diagrams. Calculated metrics of abundance‐weighted average indices (H/C, O/C, aromaticity, and m/z) of the commonly detected ions showed that hydrogen saturation and aromaticity were consistent for each reference sample across the instruments, while average mass and oxygenation were more affected by differences in instrument type and settings. In this paper we present 32 metric values for future benchmarking. The metric values were obtained for the four different parameters from four samples in two ionization modes and can be used in future work to evaluate the performance of HRMS instruments.

11 September 2019 in Environmental Science & Technology
Verified
Journal Article
Closed access
SBStephanie M. Berg
Stephanie M. Berg
QWQuinn T. Whiting
Quinn T. Whiting
JHJoseph A. Herrli
Joseph A. Herrli
RWRonan Winkels
Ronan Winkels
KWKristine H. Wammer
Kristine H. Wammer
CRChristina K. Remucal
Christina K. Remucal

30 November 2016 in Environmental Science & Technology Letters
Verified
Journal Article
Closed access
JLJuliana R. Laszakovits
Juliana R. Laszakovits
SBStephanie M. Berg
Stephanie M. Berg
BABrady G. Anderson
Brady G. Anderson
JOJessie E. O’brien
Jessie E. O’brien
KWKristine H. Wammer
Kristine H. Wammer
CSCharles M. Sharpless
Charles M. Sharpless

11 April 2023 in Environmental Science & Technology
Verified
Journal Article
Closed access
SBStephanie M. Berg
Stephanie M. Berg
KWKristine H. Wammer
Kristine H. Wammer
CRChristina K. Remucal
Christina K. Remucal

30 November 2020 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Closed access
BWBoran Wu
Boran Wu
SBStephanie M. Berg
Stephanie M. Berg
CRChristina K. Remucal
Christina K. Remucal
TSTimothy J. Strathmann
Timothy J. Strathmann

14 December 2017 in Environmental Science & Technology
Verified
Journal Article
Open access
JBJames M. Barazesh
James M. Barazesh
CPCarsten Prasse
Carsten Prasse
Jannis WenkJannis Wenk
Jannis Wenk
SBStephanie Berg
Stephanie Berg
CRChristina K. Remucal
Christina K. Remucal
DSDavid Sedlak
David Sedlak
As water scarcity intensifies, point-of-use and point-of-entry treatment may provide a means of exploiting locally available water resources that are currently considered to be unsafe for human consumption. Among the different classes of drinking water contaminants, toxic trace elements (e.g., arsenic and lead) pose substantial operational challenges for distributed drinking water treatment systems. Removal of toxic trace elements via adsorption onto iron oxides is an inexpensive and robust treatment method; however, the presence of metal-complexing ligands associated with natural organic matter (NOM) often prevents the formation of iron precipitates at the relatively low concentrations of dissolved iron typically present in natural water sources, thereby requiring the addition of iron which complicates the treatment process and results in a need to dispose of relatively large amounts of accumulated solids. A point-of-use treatment device consisting of a cathodic cell that produced hydrogen peroxide (H2O2) followed by an ultraviolet (UV) irradiation chamber was used to decrease colloid stabilization and metal-complexing capacity of NOM present in groundwater. Exposure to UV light altered NOM, converting ∼6 μM of iron oxides into settable forms that removed between 0.5 and 1 μM of arsenic (As), lead (Pb), and copper (Cu) from solution via adsorption. After treatment, changes in NOM consistent with the loss of iron-complexing carboxylate ligands were observed, including decreases in UV absorbance and shifts in the molecular composition of NOM to higher H/C and lower O/C ratios. Chronoamperometric experiments conducted in synthetic groundwater revealed that the presence of Ca2+ and Mg2+ inhibited intramolecular charge-transfer within photoexcited NOM, leading to substantially increased removal of iron and trace elements.