Konlin Shen

Konlin Shen

Auto-generated profile, based on publicly available information

Konlin Shen

University of California, San Francisco

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2020 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
KYKyrollos Yanny
Kyrollos Yanny
NANick Antipa
Nick Antipa
WLWilliam Liberti
William Liberti
SDSam Dehaeck
Sam Dehaeck
KMKristina Monakhova
Kristina Monakhova
LWLaura Waller
Laura Waller
Miniature fluorescence microscopes are a standard tool in systems biology. However, widefield miniature microscopes capture only 2D information, and modifications that enable 3D capabilities increase the size and weight and have poor resolution outside a narrow depth range. Here, we achieve the 3D capability by replacing the tube lens of a conventional 2D Miniscope with an optimized multifocal phase mask at the objective’s aperture stop. Placing the phase mask at the aperture stop significantly reduces the size of the device, and varying the focal lengths enables a uniform resolution across a wide depth range. The phase mask encodes the 3D fluorescence intensity into a single 2D measurement, and the 3D volume is recovered by solving a sparsity-constrained inverse problem. We provide methods for designing and fabricating the phase mask and an efficient forward model that accounts for the field-varying aberrations in miniature objectives. We demonstrate a prototype that is 17 mm tall and weighs 2.5 grams, achieving 2.76 μm lateral, and 15 μm axial resolution across most of the 900 × 700 × 390 μm3 volume at 40 volumes per second. The performance is validated experimentally on resolution targets, dynamic biological samples, and mouse brain tissue. Compared with existing miniature single-shot volume-capture implementations, our system is smaller and lighter and achieves a more than 2× better lateral and axial resolution throughout a 10× larger usable depth range. Our microscope design provides single-shot 3D imaging for applications where a compact platform matters, such as volumetric neural imaging in freely moving animals and 3D motion studies of dynamic samples in incubators and lab-on-a-chip devices.

1 November 2019 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
MGMohammad Meraj Ghanbari
Mohammad Meraj Ghanbari
DPDavid K. Piech
David K. Piech
KSKonlin Shen
Konlin Shen
SASina Faraji Alamouti
Sina Faraji Alamouti
CYCem Yalcin
Cem Yalcin
RMRikky Muller
Rikky Muller
A 0.8-mm 3 -wireless, ultrasonically powered, free-floating neural recording implant is presented. The device is comprised only of a 0.25-mm 2 recording integrated circuit (IC) and a single piezoceramic resonator that are used for both power harvesting and data transmission. Uplink data transmission is performed by the analog amplitude modulation of the ultrasound echo. Using a 1.78-MHz main carrier, >35 kb/s/mote equivalent uplink data rate is achieved. A technique to linearize the echo amplitude modulation is introduced, resulting in < 1.2% static nonlinearity of the received signal over a ±10-mV input range. The IC dissipates 37.7 $\mu \text{W}$ , while the neural recording front end consumes $4~\mu \text{W}$ and achieves a noise floor of 5.3 $\mu V_{\text {rms}}$ in a 5-kHz bandwidth. This work improves the sub-mm recording mote depth by >2.5 $\times $ , resulting in the highest measured depth/volume ratio by $\sim 3\times $ . Orthogonal subcarrier modulation enables simultaneous operation of multiple implants, using a single-element ultrasound external transducer. Dual-mote simultaneous power-up and data transmission are demonstrated at a rate of 7 kS/s at the depth of 50 mm.

20 April 2023 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
KSKonlin Shen
Konlin Shen
OCOliver Chen
Oliver Chen
JEJordan L. Edmunds
Jordan L. Edmunds
DPDavid K. Piech
David K. Piech
MMMichel M. Maharbiz
Michel M. Maharbiz

25 February 2021 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
KSKonlin Shen
Konlin Shen
MMMichel M Maharbiz
Michel M Maharbiz
The lifetime of neural implants is strongly dependent on packaging due to the aqueous and biochemically aggressive nature of the body. Over the last decade, there has been a drive towards neuromodulatory implants which are wireless and approaching millimeter-scales with increasing electrode count. A so-far unrealized goal for these new types of devices is an in-vivo lifetime comparable to a sizable fraction of a healthy patient’s lifetime (>10–20 years). Existing, approved medical implants commonly encapsulate components in metal enclosures (e.g. titanium) with brazed ceramic inserts for electrode feedthrough. It is unclear how amenable the traditional approach is to the simultaneous goals of miniaturization, increased channel count, and wireless communication. Ceramic materials have also played a significant role in traditional medical implants due to their dielectric properties, corrosion resistance, biocompatibility, and high strength, but are not as commonly used for housing materials due to their brittleness and the difficulty they present in creating complex housing geometries. However, thin-film technology has opened new opportunities for ceramics processing. Thin films derived largely from the semiconductor industry can be deposited and patterned in new ways, have conductivities which can be altered during manufacturing to provide conductors as well as insulators, and can be used to fabricate flexible substrates. In this review, we give an overview of packaging for neural implants, with an emphasis on how ceramic materials have been utilized in medical device packaging, as well as how ceramic thin-film micromachining and processing may be further developed to create truly reliable, miniaturized, neural implants.

6 December 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KSKonlin Shen
Konlin Shen
MMMichel M. Maharbiz
Michel M. Maharbiz
Objective: Ultrasonic acoustic power transfer is an efficient mechanism for coupling energy to millimeter and sub-millimeter implants in the body. To date, published ultrasonically powered implants have been encapsulated with thin film polymers that are susceptible to well-documented failure modes in vivo, including water penetration and attack by the body. As with all medical implants, packaging with ceramic or metallic materials can reduce water vapor transmission and improve biostability to provide decadal device lifetime. In this paper, we evaluate methods of coupling ultrasonic energy to the interior of ceramic packages. Methods: The classic wave approach and modal expansion are used to obtain analytical expressions for ultrasonic transmission through two different package designs and these approaches are validated experimentally. A candidate package design is demonstrated using alumina packages and titanium lids, designed to be acoustically transparent at ultrasonic frequencies. Results: Bulk modes are shown to be more effective at coupling ultrasonic energy to a piezoelectric receiver than flexural modes. Using bulk modes, packaged motes have an overall link efficiency of roughly 10%, compared to 25% for unpackaged motes. Packaging does not have a significant effect on translational misalignment penalties, but does increase angular misalignment penalties. Passive amplitude-modulated backscatter communication is demonstrated. Conclusion: Thin lids enable the use of ultrasonically coupled devices even with package materials of very different acoustic impedance. Significance: This work provides an analysis and method for designing packages that enable ultrasonic coupling with implantable medical devices, which could facilitate clinical translation.

1 July 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SSSoner Sonmezoglu
Soner Sonmezoglu
ADAli Darvishian
Ali Darvishian
KSKonlin Shen
Konlin Shen
MBMauricio J. Bustamante
Mauricio J. Bustamante
AKAveral Kandala
Averal Kandala
MMMichel M. Maharbiz
Michel M. Maharbiz
Acoustic links for implantable medical devices (implants) have gained attention primarily because they provide a route to wireless deep-tissue systems. The miniaturization of the implants is a key research goal in these efforts, nominally because smaller implants result in less acute tissue damage. Implant size in most acoustic systems is limited by the piezoelectric bulk crystal used for power harvesting and data communication. Further miniaturization of the piezocrystal can degrade system power transfer efficiency and data transfer reliability. Here, we present a new method for packaging the implant piezocrystal; the method maximizes power transfer efficiency ( $\eta $ ) from the acoustic power at the piezo surface to the power delivered to the electrical load and information transfer across the acoustic link. Our method relies on placing piezo-to-substrate anchors to the piezo regions where the vibrational displacement of the mode of interest is zero. To evaluate our method, we investigated packaged $1\times 1\times1$ mm 3 piezocrystals assembled with different sized anchors. Our results show that reducing the anchor size decreases anchor loss and thus improves piezo quality factor ( Q ). We also demonstrate that this method improves system electromechanical coupling. A strongly coupled, high- Q piezo with properly sized and located anchors is demonstrated to achieve significantly higher $\eta$ and superior data transfer capability at resonance. Overall, this work provides an analysis and generic method for packaging the implant piezocrystal that enables the design of efficient acoustic power and data links, which provides a path toward the further miniaturization of ultrasonic implants to submillimeter scales.