1 September 2018 in Forensic Science International: Genetics
All previous examinations of the shedder status of individuals have been based on conclusions inferred from the amount of DNA deposited by donors after they have held an object for a fixed period of time. In all interpretations of shedder status experiments have involved a range uncertainties, especially in regards to results arising from studies carried out in different laboratories. These apply to the efficiency of the swab collecting DNA from the item touched, the amount of DNA left on the swab after attempts to recover it, and the percentage loss of DNA during the lysis and extraction processes. No previous study has attempted to mitigate these uncertainties or verify how much of the DNA deposited was collected through swabbing, how much DNA present on the swab was recovered or how much DNA is lost during the extraction process. We present a study that accurately measures the deposition, collection and amplification of DNA deposited by a range of donors allowing for an accurate determination of the shedder status of individuals. Eleven donors were asked to wash their hands and then deposit a thumbprint onto glass slides by making pressure for 15 seconds 0, 15, 60 and 180 minutes after handwashing. Both left and right thumbs were used and all testing was performed in triplicate. Measurement of the quantity of cellular material deposited on the slides was carried out using DiamondTM Nucleic Acid Dye and fluorescence microscopy on each of 264 thumbprints. Fluorescence microscopy was then used to demonstrate that all the DNA present on the slides was recovered by the swabbing operations and then direct PCR, using the Identifiler™ Plus kit, was used to ensure that none of the DNA present on swabs was lost during DNA profiling. The combination of using a DNA binding dye and direct PCR allowed an accurate means of measuring the extent to which individuals exhibit different extents of shedding. This small study, 11 donors, showed that individuals fell into one of three distinct groups: heavy, intermediate, and light shedders, regardless of the hand used.
1 September 2018 in Forensic Science International: Genetics
Direct PCR from touch DNA has a range of potential applications in the field of forensic investigation for exhibit examination that, under standard extraction methods, rarely produce informative DNA profiles. Previous studies from 'touch DNA' have focussed on fingermarks created under laboratory conditions. Here we report on successful STR DNA profiling from a range of touched items. Direct PCR, with no increase in cycle number, was performed after eight different sample types, typical of those submitted for forensic investigation, were handled by volunteers for a maximum of 15 s to deposit trace amounts of their DNA. Amplifications were performed using either GlobalFiler® or Identifiler® Plus following manufacturer's instructions. These two kits were chosen deliberately as many laboratories worldwide have adopted and validated them in their workflow, thus allowing for direct PCR to be incorporated within their practises easily. It was found that informative STR profiles were obtained from all eight substrates using both STR kits. Identifiler® Plus out-performed GlobalFiler® in terms of the percentage of alleles amplified using the direct PCR approach. Both generated informative profiles from all items and all individuals, at different rates, with Identifiler® Plus being informative in a larger percentage of samples. GlobalFiler® produced profiles with an average of 60% ± 24% (36 ± 15 alleles) alleles present while Identifiler® Plus produced profiles with an average of 96% ± 4% (31 ± 1 alleles) alleles present. A comparison was made between the direct PCR approach and subjecting touched samples to a standard DNA extraction process, both using Identifiler®. An average of 4% of profiles were informative for samples that underwent extraction with 100% being informative from the same subset of samples amplified by direct PCR. Our findings further demonstrate the success of direct PCR to enhance the STR DNA profiles from touch DNA. Further, Identifiler® Plus was found to generate informative profiles more often than GlobalFiler®. Direct PCR is fast, simple, and non-destructive of evidence with the ability to generate informative genetic data where standard methods are likely to fail.
1 July 2020 in Science & Justice
3 January 2022 in Journal of Forensic Sciences
1 May 2020 in Forensic Science International: Genetics
2 February 2019 in Australian Journal of Forensic Sciences
Direct PCR can be used to successfully generate full STR profiles from latent DNA. However, some substrates have been shown to be more problematic and in some cases only partial profiles are recovered. As latent DNA is present on the surface of objects in very low quantity, and potentially low quality, the fragment lengths targeted by STR typing may be too large to successfully amplify all markers. As an alternative, QIAGEN have developed a 140-SNP multiplex that targets much shorter amplicons and generates extremely low probabilities of any two unrelated individuals having identical genotypes. Here, we present the first forensic identification SNP data from latent DNA using massively parallel sequencing. We applied the QIAGEN 140-SNP forensic identification multiplex to swabs collected from multiple substrates (including mobile phone, fingerprint, wire, zip-lock bag and SIM card) and multiple donors.