Chantelle M. de Vet

Chantelle M. de Vet

Auto-generated profile, based on publicly available information

Chantelle M. de Vet

Affiliations Department of Gynecology and Obstetrics, Máxima Medical Center, Veldhoven, Noord-Brabant, The Netherlands, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Noord-Brabant, The Netherlands, Eindhoven MedTech Innovation Center, Eindhoven, Noord-Brabant, The Netherlands

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2022 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Open access
PDF file
NON. H. M. van Oostrum
N. H. M. van Oostrum
CVC. M. de Vet
C. M. de Vet
SCS. B. Clur
S. B. Clur
DWD. A. A. van der Woude
D. A. A. van der Woude
EHE. R. van Den Heuvel
E. R. van Den Heuvel
JLJudith van Laar
Judith van Laar
Objectives: Two‐dimensional speckle‐tracking echocardiography (2D‐STE) is a promising technique which allows assessment of fetal cardiac function, and can be used in the evaluation of cardiac and non‐cardiac diseases in pregnancy. However, reliable fetal reference values for deformation parameters measured using 2D‐STE are needed before it can be introduced into clinical practice. This study aimed to obtain reference values for fetal global longitudinal strain (GLS) and GLS rate (GLSR) measured using 2D‐STE and compare right and left ventricular values.Methods: This was a prospective longitudinal cohort study of uncomplicated pregnancies that underwent echocardiography every 4 weeks from inclusion at 18–21 weeks until delivery to obtain four‐chamber loops of the fetal heart. Left and right ventricular GLS and GLSR were measured using 2D‐STE at each examination. Using Bayesian mixed‐effects models, reference values with lower and upper 5% prediction limits were calculated according to gestational age. Right and left ventricular GLS values according to gestational age were compared using the Wilcoxon signed‐rank test.Results: A total of 592 left ventricular and 566 right ventricular GLS and GLSR measurements were obtained from 124 women with uncomplicated pregnancy and non‐anomalous, appropriately grown fetuses. Reference values were obtained for both fetal ventricles according to gestational week. GLS and GLSR values of both ventricles increased (i.e. became less negative) significantly during pregnancy. Right ventricular GLS values were significantly higher (i.e. less negative) than the respective left ventricular values at every gestational week.Conclusions: Reference values were obtained for fetal GLS and GLSR measured using 2D‐STE. GLS and GLSR values increased significantly for both ventricles from the second trimester until delivery. GLS values were significantly higher for the right ventricle compared with the left ventricle. Future studies are needed to assess whether the obtained reference values are helpful in clinical practice in the assessment of pregnancy complications, such as fetal growth restriction or cardiac anomaly. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

12 July 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TNThomas Johannes Nichting
Thomas Johannes Nichting
CVChantelle M. de Vet
Chantelle M. de Vet
MVMyrthe van der Ven
Myrthe van der Ven
DWDaisy A. A. van der Woude
Daisy A. A. van der Woude
MRMarta Regis
Marta Regis
NONoortje H. M. van Oostrum
Noortje H. M. van Oostrum
Objectives: Two-dimensional speckle tracking echocardiography has been considered an angle-independent modality. However, current literature is limited and inconclusive on the actual impact of angle of insonation on strain values. Therefore, the primary objective of this study was to assess the impact of angles of insonation on the estimation of fetal left ventricular and right ventricular global longitudinal strain. Secondarily, the impact of different definitions for angles of insonation was investigated in a sensitivity analysis. Methods: This is a retrospective analysis of a prospective longitudinal cohort study with 124 healthy subjects. The analyses were based on the four-chamber view ultrasound clips taken between 18+0 and 21+6 weeks of gestation. Angles of insonation were categorized into three groups: up/down, oblique and perpendicular. The mean fetal left and right ventricular and global longitudinal strain values corresponding to these three groups were compared by an ANOVA test corrected for heteroscedasticity. Results: Fetal left and right ventricular global longitudinal strain values were not statistically different between the three angles of insonation (p-value >0.062 and >0.149, respectively). When applying another definition for angles of insonation in the sensitivity analysis, the mean left ventricular global longitudinal strain value was significantly decreased for the oblique compared to the up/down angle of insonation (p-value 0.041). Conclusions: There is no evidence of a difference in fetal left and right ventricular global longitudinal strain between the different angles of insonation in fetal two-dimensional speckle tracking echocardiography.

18 November 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CVChantelle M de Vet
Chantelle M de Vet
TNThomas Johannes Nichting
Thomas Johannes Nichting
AFAnnemarie F Fransen
Annemarie F Fransen
DWDaisy A A van der Woude
Daisy A A van der Woude
MVMyrthe van der Ven
Myrthe van der Ven
JLJudith O E H van Laar
Judith O E H van Laar
Objectives: Two-dimensional speckle tracking (2D-STE) strain analysis holds promise for assessing fetal cardiac function. Understand the learning curve before introducing 2D-STE into obstetrics is crucial. This study examined the learning curve for offline analysis of fetal left (LV) and right ventricular (RV) global longitudinal strain (GLS) using 2D-STE. Methods: After 2D-STE training, three trainees (Maternal-Fetal Medicine fellow, OBGYN resident and medical student) analyzed 100 fetal heart clips using 2D-STE to calculate LV- and RV-GLS. Intra-class correlation coefficients (ICC) and Bland-Altman plots were compared GLS values across four sets of 25 clips for each trainee against the expert. Repeated measurements analysis compared GLS score differences between expert and trainees over time and among trainees, adjusting p-values with a Bonferroni correction. Results: LV-GLS consistency evolved from poor-to-moderate during the first 50 measurements to moderate-to-good during the second 50 for all trainees. RV-GLS consistency evolved from poor-to-moderate during the first 75 measurements to moderate-to-good during the final 25 measurements for the fellow and resident. The student’s RV-GLS consistency was poor during the first 25 measurements, moderate-to good during the second 25 measurements and again poor-to-moderate during the final 50 measurements. Repeated measurements analysis showed a significant decrease in variability of the LV- and RV-GLS score differences between the expert and trainees over time (padj<0.001), which was not significantly different between trainees. Moreover, the mean of those differences were significantly different for all trainees for LV-GLS (padj<0.001) and RV-GLS (padj = 0.029), and did significantly change over time for RV-GLS (padj<0.001) but not for LV-GLS. Conclusions: A clear learning effect was observed by the significant decrease in variability of the difference in the score between the expert and trainees over time. The consistency of fetal GLS analysis with 2D-STE was generally found to be moderate to good after 100 measurements in trainees.

1 February 2023 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Closed access
CVC. M. de Vet
C. M. de Vet
NON. H. M. van Oostrum
N. H. M. van Oostrum
SCS. B. Clur
S. B. Clur
DWD. A. A. van der Woude
D. A. A. van der Woude
SOS. G. Oei
S. G. Oei
JLJ. O. E. H. van Laar
J. O. E. H. van Laar

30 August 2023 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Closed access
CVC. M. de Vet
C. M. de Vet
NON. H. M. van Oostrum
N. H. M. van Oostrum
SCS. B. Clur
S. B. Clur
SOS. G. Oei
S. G. Oei
JLJ. O. E. H. van Laar
J. O. E. H. van Laar

17 July 2024 in Fetal Diagnosis and Therapy
Verified
Journal Article
Closed access
PDF file
CVChantelle de Vet
Chantelle de Vet
HZHossy Zamani
Hossy Zamani
DWDaisy van der Woude
Daisy van der Woude
SCSally-Ann Clur
Sally-Ann Clur
GOGuid Oei
Guid Oei
NONoortje van Oostrum
Noortje van Oostrum
Introduction: The aim of this systematic review and meta-analysis was to evaluate fetal cardiac function in fetuses of mothers with diabetes compared to those of mothers without diabetes using 2D-STE. Methods: Embase, MEDLINE, and CENTRAL were searched for observational studies on 2D-STE fetal left and right ventricular global longitudinal strain and strain rate that included singleton, non-anomalous pregnancies complicated by pregestational or gestational diabetes mellitus compared to uncomplicated pregnancies. The strain values were pooled per 4 weeks of gestation for meta-analysis using random-effects models. Results: Fifteen studies met the criteria, including 990 fetuses of diabetic mothers and 1,645 control fetuses. The study design was cross-sectional in fourteen studies and longitudinal in one study. Gestational age, type of diabetes, ultrasound device, and 2D-STE software varied between the studies. Glycemic control and type of treatment were often lacking. In fetuses of diabetic mothers versus healthy mothers, left ventricular strain was significantly decreased (7 studies), increased (1 study), or not significantly different (7 studies). Right ventricular strain was decreased (7 studies), increased (1 study), or not different (2 studies). Left ventricular strain rate was decreased (3 studies), increased (1 study), or not different (2 studies). Right ventricular strain rate was increased (1 study) or not different (2 studies). Conclusion: Fetuses of mothers with diabetes show evidence of systolic dysfunction, which is more visible in the right ventricle. Contradictory results are probably due to suboptimal study designs and variation in gestational age, diabetes severity, image acquisition, and software. Large prospective longitudinal studies are needed to assess fetal myocardial function with 2D-STE in pregestational diabetes mellitus type 1 and 2 and gestational diabetes mellitus pregnancies. The influence of glycemic control, BMI, and treatment should be evaluated.