21 January 2019 in IEEE Transactions on Magnetics
Transcranial magnetic stimulation (TMS) is a non-invasive neuromodulation technique that is used for treating various neurological disorders such as major depressive disorder. TMS has been gaining popularity in the field of neurostimulation of the cerebellum, since the cerebellum is a complex structure connected with almost the entire central nervous system and TMS has promise for non-invasively probing cerebellar function. Recent studies have discovered that the cerebellum plays an important role not only in motor planning and behavior but also in the cognitive domain. However, few studies have explored how different coil designs and anatomical variations affect the effectiveness of cerebellar TMS. Therefore, in this paper, we investigated the effects of cerebellar TMS with different coil designs positioning on several locations. Finite-element modeling was conducted with Figure-8 coil and D-B80 coil. Each coil was positioned in the center, 1 and 3 cm to the left of center of the cerebellum, and all the locations were tangential to the scalp at a distance of 5 mm. Furthermore, 50 MRI derived head models were used in the computer modeling to examine how anatomical variations affect the distribution and intensity of electric field in cerebellar TMS.
9 August 2021 in IEEE Transactions on Magnetics
Transcranial magnetic stimulation (TMS) is a non-invasive neuromodulation technique investigated for the treatment of various neuropsychiatric disorders such as major depressive disorder and obsessive-compulsive disorder. Coil design and analysis has been a popular topic in TMS studies, primarily as the coil geometry significantly affects the induced electric field ( $E$ -field) distribution. In this work, we compare the distribution of the induced $E$ -field of 16 different TMS coils by finite element analysis. The coils are positioned at two head locations: the vertex and the dorsolateral prefrontal cortex (DLPFC). Due to the coil geometry, only nine of the 16 coils are positioned at the DLPFC. Notably, the authors use 50 heterogeneous head models derived from MRI scans of healthy patients in this analysis. As a result, the sensitivity of the $E$ -field intensity and focality to anatomical variations is investigated. The maximum $E$ -field intensity induced in the brain ( $E$ -Max brain), and the volume in the brain exposed to the $E$ -field with at least half the $E$ -Max ( $V$ -Half) were metrics used to assess the intensity and focality of the induced $E$ -field. It was observed that some of the coils induced high $E$ -field intensity and were highly sensitive to anatomical variations. Other coils exhibited high focality and lower sensitivity to anatomical variations at the same time. For the coils positioned at the DLPFC, less variability was observed when compared to the vertex location. This study provides an understanding of the effect of coil geometry and anatomical variation on the induced $E$ -field during TMS.
18 December 2017 in AIP Advances
Transcranial magnetic stimulation (TMS) is a safe and non-invasive treatment for neurological disorders. TMS has been approved as a treatment for major depressive disorders by the US Food and Drug Administration (FDA) in 2008. Due to the phenomenon of electromagnetic induction, a time-varying magnetic field induces an electric field in the conductive tissues in the brain, TMS has the ability to activate neurons in vivo. However, the effects of the magnetic fields on neurons in cell culture have not been investigated adequately. The magnetic fields affect the neurons when the potential across the neuronal membrane exceeds the threshold which in turn causes an action potential. Based on these theories, we investigated the effects of the magnetic fields generated by a monophasic stimulator with a 70 mm double coil on rat dopaminergic neuronal cell lines (N27). The directions of the magnetic fields in each coil of the double coil oppose each other. The effects of changing the direction of the magnetic field on N27 neurons was also investigated. The results of the experiments showed that both of the fields perpendicular to the coil surface promoted the proliferation of N27 dopaminergic neurons. In order to investigate the gene expression and protein expression affected by TMS, quantitative Polymerase Chain Reaction (qPCR) was used. Here we report changes in glial cell line-derived neurotrophic factor (GDNF) in dopaminergic neuronal cells (N27) after TMS treatment.
1 April 2025 in IEEE Transactions on Magnetics
Transcranial magnetic stimulation (TMS) holds great promise for noninvasively diagnosing and treating neurological disorders. Based on the electromagnetic induction principle, the TMS coil’s alternating magnetic fields generate electric fields in targeted brain areas. However, the intricate and diverse brain structures across individuals pose challenges in predicting and enhancing the effectiveness of TMS treatments for a particular patient. In this study, computational modeling was utilized with fifty realistic, heterogeneous head models to investigate how individual differences influence the induced electric fields, focusing on their intensity and focality. The finite element method was applied to calculate the induced electric field in the brain. Seven commercially available TMS coils were placed at two anatomical locations: the vertex and the dorsolateral prefrontal cortex (DLPFC). The findings indicate that similar coil configurations produce consistent induced electric field strengths across subjects. More notably, this study examined the differences in induced electric field intensity among coils for each individual, rather than merely grouping subjects, underscoring the importance of individual variation. This research provides valuable reference and support for optimizing TMS device configurations and treatment protocols in practical clinical applications.