Heng Wang

Heng Wang

Auto-generated profile, based on publicly available information

Heng Wang

School of Mechatronical Engineering Beijing Institute of Technology Beijing China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2021 in Human Brain Mapping
Verified
Journal Article
Open access
PDF file
HWHeng Wang
Heng Wang
WSWeiqian Sun
Weiqian Sun
JZJianxu Zhang
Jianxu Zhang
ZYZilong Yan
Zilong Yan
CWChenyu Wang
Chenyu Wang
Tianyi YanTianyi Yan
Tianyi Yan
With the development of electrical stimulation technology, especially the emergence of temporally interfering (TI) stimulation, it is necessary to discuss the influence of current frequency on stimulation intensity. Accurate skull modeling is important for transcranial current stimulation (tCS) simulation prediction because of its large role in dispersing current. In this study, we simulated different frequencies of transcranial alternating current stimulation (tACS) and TI stimulation in single‐layer and layered skull model, compared the electric field via error parameters such as the relative difference measure and relative magnification factor. Pearson correlation analysis and t‐test were used to measure the differences in envelope amplitude. The results showed that the intensity of electric field in the brain generated by per unit of stimulation current will increase with current frequency, and the layered skull model had a better response to frequency. An obvious pattern difference was found between the electric fields of the layered and single‐layer skull individualized models. For TI stimulation, the Pearson correlation coefficient between the envelope distribution of the layered skull model and the single‐layer skull was only 0.746 in the individualized model, which is clearly lower than the correlation coefficient of 0.999 determined from the spherical model. Higher carrier frequencies seemed to be easier to generate a large enough brain electric field envelope in TI stimulation. In conclusion, we recommend using layered skull models instead of single‐layer skull models in tCS (particularly TI stimulation) simulation studies in order to improve the accuracy of the prediction of stimulus intensity and stimulus target.

10 October 2023 in Journal of the Audio Engineering Society
Verified
Journal Article
Closed access
PDF file
CMCatarina Mendonça
Catarina Mendonça
HWHeng Wang
Heng Wang
VPVille Pulkki
Ville Pulkki
The current technological solutions for spatial audio provide realistic auditory impressions but rarely account for multisensory interactions. The intent of this study was to discover if and when spatial sounds could lower the accuracy of visual perception. Sequences of light and sound events were presented, and different sound parameters were tested: spatial and temporal congruency, horizontal and vertical spatial distribution, and source broadness. Participants were asked to report the...