17 February 2021 in Journal of Scientific Computing
27 May 2023 in Engineering with Computers
We present an algorithm for hp-adaptive collocation-based mesh-free numerical analysis of partial differential equations. Our solution procedure follows a well-established iterative solve–estimate–mark–refine paradigm. The solve phase relies on the Radial Basis Function-generated Finite Differences (RBF-FD) using point clouds generated by advancing front node positioning algorithm that supports variable node density. In the estimate phase, we introduce an Implicit-Explicit (IMEX) error indicator, which assumes that the error relates to the difference between the implicitly obtained solution (from the solve phase) and a local explicit re-evaluation of the PDE at hand using a higher order approximation. Based on the IMEX error indicator, the modified Texas Three Step marking strategy is used to mark the computational nodes for h-, p- or hp-(de-)refinement. Finally, in the refine phase, nodes are repositioned and the order of the method is locally redefined using the variable order of the augmenting monomials according to the instructions from the mark phase. The performance of the introduced hp-adaptive method is first investigated on a two-dimensional Peak problem and further applied to two- and three-dimensional contact problems. We show that the proposed IMEX error indicator adequately captures the global behaviour of the error in all cases considered and that the proposed hp-adaptive solution procedure significantly outperforms the non-adaptive approach. The proposed hp-adaptive method stands for another important step towards a fully autonomous numerical method capable of solving complex problems in realistic geometries without the need for user intervention.
25 January 2022 in IEEE Transactions on Power Systems
Transmission system operators (TSOs) in recent years have faced challenges in order to ensure maximum transmission capacity of the system to satisfy market needs, while maintaining operational safety and permissible impact on the environment. A great help in the decision-making process was introduced with the Dynamic Thermal Rating (DTR) – an instrument to monitor and predict the maximal allowed ampacity of the power grid based on weather measurements and forecast. However, the introduction of DTR raises a number of questions related to the accuracy and uncertainty of the results of thermal assessment and the level of acceptable risk and its management. In this paper, we present a solution for estimating DTR uncertainty, appropriate for operational use at TSOs. With the help of conductor surface temperature measurements, weather measurements and predicted weather data, we also estimate the error of the weather forecast and the DTR itself. Following the results of the data analyses, we build an operative solution for estimating the ampacity uncertainty based on Monte Carlo random simulations and integrate it into the operational environment of ELES – the operator of the Slovenian electric power transmission network.
23 September 2024 in Applied Mathematical Modelling
28 March 2024 in Journal of Computational Physics
30 April 2024 in Journal of Computational Science