Adam L. Hollerbach

Adam L. Hollerbach

Auto-generated profile, based on publicly available information

Adam L. Hollerbach

Pacific Northwest National Laboratory

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2020 in Analytical Chemistry
Verified
Journal Article
Closed access
AHAdam L. Hollerbach
Adam L. Hollerbach
ALAilin Li
Ailin Li
APAneesh Prabhakaran
Aneesh Prabhakaran
GNGabe Nagy
Gabe Nagy
CHChristopher P. Harrilal
Christopher P. Harrilal
YIYehia M. Ibrahim
Yehia M. Ibrahim

3 October 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
AHAdam Hollerbach
Adam Hollerbach
PFPatrick Fedick
Patrick Fedick
RCR. Graham Cooks
R. Graham Cooks

13 April 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
AHAdam Hollerbach
Adam Hollerbach
ZBZane Baird
Zane Baird
RCR. Graham Cooks
R. Graham Cooks

26 October 2020 in Analytical Chemistry
Verified
Journal Article
Open access
ALAilin Li
Ailin Li
GNGabe Nagy
Gabe Nagy
CCChristopher R. Conant
Christopher R. Conant
RNRandolph V. Norheim
Randolph V. Norheim
JLJOON-YONG LEE
JOON-YONG LEE
SGSandilya Garimella
Sandilya Garimella
Ion packets introduced from gates, ion funnel traps, and other conventional ion injection mechanisms produce ion pulse widths typically around a few microseconds or less for ion mobility spectrometry (IMS)-based separations on the order of 100 milliseconds. When such ion injection techniques are coupled with ultralong path length traveling wave (TW)-based IMS separations (i.e., on the order of seconds) using structures for lossless ion manipulations (SLIMs), typically very low ion utilization efficiency is achieved for continuous ion sources [e.g., electrospray ionization (ESI)]. Even with the ability to trap and accumulate much larger populations of ions than being conventionally feasible over longer time periods in SLIM devices, the subsequent long separations lead to overall low ion utilization. Here, we report the use of a highly flexible SLIM arrangement, enabling concurrent ion accumulation and separation and achieving near-complete ion utilization with ESI. We characterize the ion accumulation process in SLIM, demonstrate >98% ion utilization, and show both increased signal intensities and measurement throughput. This approach is envisioned to have broad utility to applications, for example, involving the fast detection of trace chemical species.

8 November 2017 in The Analyst
Verified
Journal Article
Closed access
PDF file
AHAdam Hollerbach
Adam Hollerbach
DLDavid Logsdon
David Logsdon
KIKiran Iyer
Kiran Iyer
ALAnyin Li
Anyin Li
JSJ. Andy Schaber
J. Andy Schaber
RCR. Graham Cooks
R. Graham Cooks
Electrosprayed droplets are widely studied for their role in the formation of ions at atmospheric pressure.

12 June 2023 in Analytical Chemistry
Verified
Journal Article
Closed access
AHAdam L. Hollerbach
Adam L. Hollerbach
YIYehia M. Ibrahim
Yehia M. Ibrahim
VMVanessa Meras
Vanessa Meras
RNRandolph V. Norheim
Randolph V. Norheim
AHAdam P. Huntley
Adam P. Huntley
RSRichard D. Smith
Richard D. Smith