15 July 2024 in IEEE Transactions on Instrumentation and Measurement
Micro-computed tomography (micro-CT) is a widely used state-of-the-art instrument employed to study the morphological structures of objects in various fields. However, its small field-of-view (FOV) cannot meet the pressing demand for imaging relatively large objects at high spatial resolutions. Recently, we devised a novel scanning mode called multiple source translation CT (mSTCT) that effectively enlarges the FOV of the micro-CT and correspondingly developed a virtual projection-based filtered backprojection (V-FBP) algorithm for reconstruction. Although V-FBP skillfully solves the truncation problem in mSTCT, it requires densely sampled projections to arrive at high-resolution reconstruction, which reduces imaging efficiency. In this paper, we develop two backprojection-filtration (BPF)-based algorithms for mSTCT—S-BPF (derivatives along source) and D-BPF (derivatives along detector). D-BPF can achieve high-resolution reconstruction with fewer projections than V-FBP and S-BPF. Through simulated and physical experiments conducted in this paper, we demonstrate that D-BPF can dramatically reduce the number of projection views compared with V-FBP at the same spatial resolution, which makes mSTCT more feasible in practice. Meanwhile, S-BPF can yield more stable results than D-BPF, which is similar to V-FBP.
1 August 2023 in AIP Advances
Wireless sensing technologies have exploited various methods for contactless respiration monitoring. One of the main methods is to use an acoustic beam to cover the chest and abdomen with real-time and high-resolution ranging. The system with high ranging resolution can detect small distance transformations, further affecting the precision of respiratory monitoring. However, the traditional range-based respiration monitoring systems are limited by an insufficient sampling rate and poor synchronization. The ranging resolution is between millimeters and centimeters. In this study, we introduced a novel, high-precision ultrasound-based system for contactless respiration monitoring. First, we developed a convenient and high-performance ultrasonic transceiver platform with universal serial bus audio architecture to eliminate the above limitations. The developed platform provides a foundation for acoustic sensing. Furthermore, based on this platform, we designed a cross correlation sine-frequency modulation continuous wave ranging method and a real-time respiration wave recovery method. The median error in monitoring respiration for 12 participants in three different sleep postures is 0 breaths/min, and the maximum error is 0.58 breaths/min. The proposed system has strong robustness concerning different respiration rates, long-term continuous respiration monitoring, and simulated apnea.