Andrea Uribe

Andrea Uribe

Auto-generated profile, based on publicly available information

Andrea Uribe

Univ Rosario, Fdn Cardioinfantil, Compensar Entidad Promotora Salud, Programa Diabet Alta Complejidad, Cl 163a 13b 60, Bogota 110141, Colombia

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2023 in JMIR Diabetes
Verified
Journal Article
Open access
MOMiguel O'Meara
Miguel O'Meara
JAJuan Camilo Mateus Acuña
Juan Camilo Mateus Acuña
AUAndrea Uribe
Andrea Uribe
Background: There is evidence in the literature that the use of sensor-augmented insulin pumps in patients with high-complexity diabetes improves metabolic control. However, there is no long-term information on clinical outcomes such as hospitalization or admission to the emergency room. This study describes outcomes for metabolic control, incidence of hospitalizations, and emergency room visits in a specific population using this technology. Objective: We aimed to assess long-term glycemic and clinical outcomes after the use of continuous subcutaneous insulin infusion and continuous glucose monitoring in people with diabetes. Methods: A retrospective cohort study was carried out in patients with diabetes previously treated with an intensive insulin regimen at a specialized diabetes treatment center who required a sensor-augmented insulin pump due to nonoptimal glycemic control. Glycated hemoglobin, severe hypoglycemic episodes, nonsevere hypoglycemic episodes, perception of hypoglycemia, and the incidence of emergency room visits and hospitalizations before and after treatment were evaluated. Results: Between January 2013 and August 2020, 74 patients with a median age of 36 (IQR 27-46) years were included in the study with a median 4 (IQR 2-7) years of follow-up. We found a statistically significant reduction in glycated hemoglobin (8.35% vs 7%; P<.001), nonsevere hypoglycemic episodes (71/74, 96% vs 62/74, 84%; P=.01), emergency room visits (42/73, 58% vs 4/62, 6%; P<.001), and hospitalizations (36/72, 50% vs 10/72, 14%; P<.001) after use of continuous subcutaneous insulin infusion. Conclusions: The use of a sensor-augmented insulin pump associated with a strict follow-up program for patients with high-complexity diabetes led to a significant and sustained reduction in glycated hemoglobin and hypoglycemic episodes, as well as in the rate of emergency room visits and hospitalizations. These results encourage the adoption of this technology in patients who do not achieve metabolic control with optimal management of diabetes.

28 February 2023 in JMIR Preprints
Verified
Preprint
Open access
MOMiguel O'Meara
Miguel O'Meara
JAJuan Camilo Mateus Acuña
Juan Camilo Mateus Acuña
AUAndrea Uribe
Andrea Uribe
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: There is evidence in the literature that the use of sensor-augmented insulin pumps in patients with high-complexity diabetes improves metabolic control. However, there is no long-term information on clinical outcomes such as hospitalization or admission to the emergency room. This study describes outcomes for metabolic control, incidence of hospitalizations, and emergency room visits in a specific population using this technology. Objective: We aimed to assess long-term glycemic and clinical outcomes after the use of continuous subcutaneous insulin infusion and continuous glucose monitoring in people with diabetes. Methods: A retrospective cohort study was carried out in patients with diabetes previously treated with an intensive insulin regimen at a specialized diabetes treatment center who required a sensor-augmented insulin pump due to nonoptimal glycemic control. Glycated hemoglobin, severe hypoglycemic episodes, nonsevere hypoglycemic episodes, perception of hypoglycemia, and the incidence of emergency room visits and hospitalizations before and after treatment were evaluated. Results: Between January 2013 and August 2020, 74 patients with a median age of 36 (IQR 27-46) years were included in the study with a median 4 (IQR 2-7) years of follow-up. We found a statistically significant reduction in glycated hemoglobin (8.35% vs 7%; P<.001), nonsevere hypoglycemic episodes (71/74, 96% vs 62/74, 84%; P=.01), emergency room visits (42/73, 58% vs 4/62, 6%; P<.001), and hospitalizations (36/72, 50% vs 10/72, 14%; P<.001) after use of continuous subcutaneous insulin infusion. Conclusions: The use of a sensor-augmented insulin pump associated with a strict follow-up program for patients with high-complexity diabetes led to a significant and sustained reduction in glycated hemoglobin and hypoglycemic episodes, as well as in the rate of emergency room visits and hospitalizations. These results encourage the adoption of this technology in patients who do not achieve metabolic control with optimal management of diabetes.