Cristobal Ruiz-Carcel

Cristobal Ruiz-Carcel

Auto-generated profile, based on publicly available information

Cristobal Ruiz-Carcel

Cranfield University

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Control Engineering Practice
Verified
Journal Article
Open access
CRC. Ruiz-Cárcel
C. Ruiz-Cárcel
YCY. Cao
Y. Cao
DMD. Mba
D. Mba
LLLiyun Lao
Liyun Lao
RSR.T. Samuel
R.T. Samuel
Industrial needs are evolving fast towards more flexible manufacture schemes. As a consequence, it is often required to adapt the plant production to the demand, which can be volatile depending on the application. This is why it is important to develop tools that can monitor the condition of the process working under varying operational conditions. Canonical Variate Analysis (CVA) is a multivariate data driven methodology which has been demonstrated to be superior to other methods, particularly under dynamically changing operational conditions. These comparative studies normally use computer simulated data in benchmark case studies such as the Tennessee Eastman Process Plant (Ricker, N.L. Tennessee Eastman Challenge Archive, Available at 〈http://depts.washington.edu/control/LARRY/TE/download.html〉 Accessed 21.03.2014). The aim of this work is to provide a benchmark case to demonstrate the ability of different monitoring techniques to detect and diagnose artificially seeded faults in an industrial scale multiphase flow experimental rig. The changing operational conditions, the size and complexity of the test rig make this case study an ideal candidate for a benchmark case that provides a test bed for the evaluation of novel multivariate process monitoring techniques performance using real experimental data. In this paper, the capabilities of CVA to detect and diagnose faults in a real system working under changing operating conditions are assessed and compared with other methodologies. The results obtained demonstrate that CVA can be effectively applied for the detection and diagnosis of faults in real complex systems, and reinforce the idea that the performance of CVA is superior to other algorithms

1 January 2019 in Annual Reviews in Control
Verified
Journal Article
Open access
Christos EmmanouilidisChristos Emmanouilidis
Christos Emmanouilidis
PPPetros Pistofidis
Petros Pistofidis
LBLuka Bertoncelj
Luka Bertoncelj
VKVassilis Katsouros
Vassilis Katsouros
AFApostolos Fournaris
Apostolos Fournaris
CRCristobal Ruiz-Carcel
Cristobal Ruiz-Carcel

1 January 2016 in Mechanical Systems and Signal Processing
Verified
Journal Article
Open access
CRC. Ruiz-Cárcel
C. Ruiz-Cárcel
VJV.H. Jaramillo
V.H. Jaramillo
DMD. Mba
D. Mba
JOJ.R. Ottewill
J.R. Ottewill
YCY. Cao
Y. Cao

1 July 2014 in Engineering Failure Analysis
Verified
Journal Article
Closed access
Faris ElashaFaris Elasha
Faris Elasha
CRCristobal Ruiz-Cárcel
Cristobal Ruiz-Cárcel
DMDavid Mba
David Mba
GKGoh Kiat
Goh Kiat
INIke Nze
Ike Nze
GYGeorge Yebra
George Yebra

27 March 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
CRCristobal Ruiz-Carcel
Cristobal Ruiz-Carcel
ASAndrew Starr
Andrew Starr
Modern industrial facilities, as well as vehicles and many other assets, are becoming highly automated and instrumented. As a consequence, actuators are required to perform a wide variety of tasks, often for linear motion. However, the use of tools to monitor the condition of linear actuators is not widely extended in industrial applications. This paper presents a data-based method to monitor linear electro-mechanical actuators. The proposed algorithm makes use of features extracted from electric current and position measurements, typically available from the controller, to detect and diagnose mechanical faults. The features are selected to characterize the system dynamics during transient and steady-state operation and are then combined to produce a condition indicator. The main advantage of this approach is the independence from a need for a physical model or additional sensors. The capabilities of the method are assessed using a novel experimental linear actuator test rig specially designed to recreate fault scenarios under different operating conditions.

1 September 2016 in Control Engineering Practice
Verified
Journal Article
Open access
CRC. Ruiz-Cárcel
C. Ruiz-Cárcel
LLLiyun Lao
Liyun Lao
YCY. Cao
Y. Cao
DMD. Mba
D. Mba
Condition monitoring of industrial processes can minimize maintenance and operating costs while increasing the process safety and enhancing the quality of the product. In order to achieve these goals it is necessary not only to detect and diagnose process faults, but also to react to them by scheduling the maintenance and production according to the condition of the process. The objective of this investigation is to test the capabilities of canonical variate analysis (CVA) to estimate performance degradation and predict the behavior of a system affected by faults. Process data was acquired from a large-scale experimental multiphase flow facility operated under changing operational conditions where process faults were seeded. The results suggest that CVA can be used effectively to evaluate how faults affect the process variables in comparison to normal operation. The method also predicted future process behavior after the appearance of faults, modeling the system using data collected during the early stages of degradation