19 December 2017 in IEEE Transactions on Power Electronics
In some application circumstances, both positive and negative sequence reactive power compensation are desired from the star-connected cascaded H-bridge static synchronous compensator (CHB STATCOM). However, the imbalanced phase currents/voltages will cause the uneven active power flow among three clusters, which makes the cluster voltage balance more challenging. In this scenario, only zero sequence voltage is available to balance the cluster voltages. Although the zero sequence voltage can be calculated in all operating conditions based on the equilibrium of the active power for each phase cluster, the calculation is definitely complicated due to the zero sequence voltage expressed in the form of trigonometric function in the abc or dq0 frame. In this paper, the zero sequence voltage is represented in a DC form in the dq frame through introducing a virtually orthogonal zero sequence voltage. As a result, a linear relationship between the active powers and the zero sequence voltage is established, based on which, a simple zero sequence voltage calculation method is proposed with a small calculation burden. Furthermore, the accurate compensation region for the negative sequence current injection is identified by establishing the relationship between the maximum converter voltage and the negative sequence currents taking into consideration the initial phase angle of the negative sequence currents, while still keeping the cluster voltage balanced by using zero sequence voltage control. The effectiveness of the proposed control and the compensation region are verified by the simulation and experimental results on a 400V/±7.5kVAr star-connected CHB STATCOM.
6 June 2018 in IEEE Transactions on Power Electronics
Under unbalanced grid, three cluster voltages are typically controlled balanced and unchanged for the star-connected cascaded H-bridge static synchronous compensator (CHB STATCOM), however, to deal with the unbalanced grid voltages, the modulation voltages become unbalanced, which would result in fewer steps of the staircase voltages and unbalanced double-line-frequency ripples across the cluster voltages. Thus, the harmonic performance of the currents is deteriorated. In addition, the negative sequence currents are always injected for active power redistribution, which degrades the power quality. To improve the current performance under the unbalanced grid, three cluster voltages are regulated to different values and three-phase modulation voltages can maintain balance. Based on this concept, three cluster voltages can be derived by decomposing the positive- and negative-sequence components from the converter voltages to meet the balance of three-phase currents. To ensure the cluster voltages stable, the zero-sequence voltage is further extracted to analyze the active power distribution. It is interesting to find that the total active power in each phase induced by both the negative and zero-sequence voltages is equal to zero, which reveals the CHB STATCOM has the natural zero-active-power feature. To keep three unequal cluster voltages within a certain boundary, the relationship between the unbalanced grid voltages and the cluster voltages is established, based on which the algorithm of limiting the cluster voltages is proposed. The theoretical analysis and the proposed control scheme are verified by the simulation and experimental results.
11 February 2021 in IEEE Transactions on Power Electronics
The LLC-based single-stage ac/dc converter can achieve zero voltage switching under full load range, which offers a very attractive solution to realize high efficiency, low cost, and extreme compactness of ac/dc power conversion. However, with the introduction of LLC resonant tank in this ac/dc conversion, it becomes very challenging to accurately analyze the steady-state characterization of the converter due to its complex resonant circuit behaviors and time-varying ac input voltage. Although some analysis methods, like first-order harmonics approximation (FHA), extended FHA, and multiharmonic approximation, etc., can be adopted to analyze this converter, they cannot obtain the accurate gain curves, especially when the switching frequency deviates far from the resonant frequency. In this situation, the numerical analysis method is offered to cope with the difficulties resulting from time-varying ac input and dc output fluctuation. A set of equations describing resonant circuit behaviors, power conservation, inductor current, and capacitor voltage are presented. Also, the numerical analysis procedure is given in detail. The numerical calculation results are found that they match with those results in PSIM simulation pretty well. A 1-kW 48-V output prototype is built to verify the effectiveness of the numerical analysis.
7 January 2022 in IEEE Transactions on Power Electronics
Since LLC converter is capable of naturally creating the soft-switching condition to improve the overall efficiency, it is widely used in dc–dc applications. Using LLC resonant tank to realize soft switching for three-phase ac–dc converters would be a very promising solution to high efficiency and low cost ac–dc conversion, an LLC -based three-phase single-stage ac–dc converter was configured by taking advantage of three-phase voltage feature $ u_{\mathrm a}$ + $ u_{\mathrm b}$ + $ u_{\mathrm c}$ = 0 and incorporating three bidirectional switches. Because of time-varying feature of three-phase voltages, the input voltage of the converter to the LLC resonant tank is no longer a symmetrical square wave, but a time-varying and asymmetrical three-level waveform, which makes the analysis of the resonant circuit behavior much complicated. Some traditional analysis methods, such as fundamental harmonic approximation and its variants, are impossible to deal with. To overcome this analysis obstacle, this article proposes a numerical analysis method to analyze the time-varying three-level LLC resonant tank for this converter. According to the monotonous change of LLC input voltage in one fundamental cycle, it calculates and determines the time durations of three phases and the corresponding operation modes in each switching cycle. And this numerical analysis method is used to calculate the numerical relationship between the two control variables (switching frequency $ f_{\mathrm s}$ and duty cycle $ D_{\mathrm M}$ ) of this converter and the voltage gain and power level, which is a guideline for the design of the resonant tank parameters and control strategy of the LLC -based three-phase single-stage ac–dc converter. Finally, the time-varying waveforms of $ f_{\mathrm s}$ and $ D_{\mathrm M}$ obtained by numerical calculation well match the PSIM simulation results, and a 3.3-kW three-phase 220Vac input and 48Vdc output prototype was built to verify the effectiveness of the proposed numerical analysis method and the feasibility of the control strategy.
2 November 2022 in IEEE Transactions on Industrial Electronics
Compared with the traditional single-voltage loop control strategy in LLC converters, the charge-controlled LLC converter can significantly improve its dynamic response due to its model having the first-order feature. Generally, a load current feedforward method could improve the converter's dynamic response. However, for the LLC converter, it is almost impractical due to the unclear relationship between the load current and the control variable. To build this relationship, a mathematical expression between the load current change and the control variable is derived that can precisely offset the load disturbance and achieve faster dynamic response. The derived relationship is nonlinear, related to both input and output voltages and switching frequency, and is suitable for digital implementation. To further analyze the dynamic response, the output impedances with and without the load current feedforward control are established and analyzed, which visually demonstrate the dynamic improvement in the time domain through the calculation of the output impedance and load change spectrum in the frequency domain. Finally, a 120 W LLC prototype with nominal 48 V input and 12 V output is built to verify the nonlinear load current feedforward control and its analysis.
7 April 2021 in IEEE Transactions on Power Electronics
DC voltage balance based on zero sequence voltage is commonly used for star-connected cascaded H-Bridge (SCHB) STATCOM to compensate negative sequence current. However, zero sequence voltage injection brings about side-effect of increasing STATCOM output voltage and thus the Negative sequence Current Compensation Range (NCCR) is significantly limited to avoid overmodulation. To extend the NCCR, improving the dc voltage utilization by injecting third harmonic component is a typical method. Compared with third harmonic injection (THI), square wave features lower peak-to-average ratio. Unfortunately, the capability of square wave injection (SWI) for the NCCR extension has not been well explored. In this article, to further extend NCCR, not only the SWI is employed for SCHB STATCOM, but also it is compared with THI in term of NCCR by establishing the relationship between the maximum STATCOM voltage and negative sequence current. The comparison results reveal that the THI and SWI both have their own strengths and weaknesses in NCCR, which highly depends on the amplitudes and phases of positive and negative sequence currents. Furthermore, the criteria associated with the amplitudes and phases of the positive and negative sequence currents are derived to determine the harmonic injection method with larger NCCR by using symbolic-graphic combination method and MATLAB tools. As a result, a new harmonic injection method is proposed by selecting the THI or SWI with larger NCCR flexibly according to the amplitudes and phases of positive and negative sequence currents. Finally, the proposed method is verified by experimental results on a 400 V/7.5 kVar SCHB STATCOM prototype.