28 March 2013 in IEEE Transactions on Power Systems
The paper considers the optimal power flow (OPF) of a meshed AC/DC power transmission network with voltage source converter based multi-terminal DC (VSC-MTDC) networks. The OPF problem is formulated to minimize the transmission loss of the whole AC/DC network with two different VSC control strategies considered, constant DC voltage control (master-slave control) and DC voltage droop control. In addition, Grid Code compliance of wind farms is also embedded in the OPF formulation. The presented OPF is evaluated and demonstrated in the paper by two example meshed AC/DC power systems.
18 November 2011 in IEEE Transactions on Power Systems
This paper proposes a method of probabilistic analysis to investigate the impact of stochastic uncertainty of grid-connected wind generation on power system small-signal stability. The proposed method is “analytical” in contrast to the numerical method of Monte Carlo simulation which relies on large number of random computations. It can directly calculate the probabilistic density function (PDF) of critical eigenvalues of a large-scale power system from the PDF of grid-connected multiple sources of wind power generation, thus to determine the probabilistic small-signal stability of the power system as affected by the wind generation. In the paper, an example of 16-machine power system with three grid-connected wind farms is used to demonstrate the application of the proposed method. The results of probabilistic stability analysis of the example power system are confirmed by the Monte Carlo simulation. It is shown that the stochastic variation of grid-connected wind generation can cause the system to lose stability even though the system is stable deterministically. The higher the level of wind penetration is, the more the probability that the system becomes unstable could be. Hence indeed penetration of stochastically variable wind generation threatens stable operation of power systems as far as system small-signal stability is concerned.
12 February 2018 in IEEE Transactions on Power Systems
Frequency deviation of power systems caused by grid-connected wind power fluctuations is one of the key factors which restrains the increase of wind penetration level. This paper examines a combined wind and hybrid energy storage system (HESS, supercapacitor and battery) to smooth wind power fluctuations without wind spillage. A fuzzy based wind-HESS system (FWHS) controller is proposed to suppress the wind power fluctuations. The proposed controller takes full advantage of the complimentary characteristics of the supercapacitor and battery with the supercapacitor and battery in charge of high and middle frequency components of wind fluctuations respectively. The efficient state of change (SoC) operation is considered. A differential evolution (DE) based optimal sizing method for wind-HESS systems is introduced to evaluate the minimum capacity of HESS as being limited by grid frequency deviation. The efficiency of the proposed scheme in the paper for wind-HESS system is evaluated by an real Chinese power system.
14 October 2015 in IEEE Transactions on Power Systems
A frequency-based approach is proposed in this paper to size a battery-supercapacitor energy storage system for maintaining power balance of an isolated system with high penetration of wind generation, thus to maintain the grid frequency stability with the stochastic wind power fluctuations being considered. The sizing method proposed makes full use of the combined technical merits of two types of energy storage systems, battery and supercapacitor, as their specific power/energy densities and the corresponding expected life cycle cost/year are different. The power imbalance between hourly dispatched wind power and the corresponding actual real-time wind power output is decomposed into different time-varying periodic components by use of the Fourier transformation. Then two different types of energy storage systems are applied to balance the low-frequency and intermediate-frequency component respectively. A computational procedure is developed in the paper for choosing the optimal cut-off frequencies in determining the range of low and intermediate frequency for sizing the hybrid energy storage system. Comparative studies of a real isolated system in China are presented in the paper to demonstrate the effectiveness of the proposed method.
30 January 2019 in IEEE Transactions on Power Systems
This paper examines the small-signal angular stability of a power system affected by a virtual synchronous generator (VSG). The examination is based on an interconnected model with two subsystems. The VSG under the examination is modeled as the VSG subsystem. The rest of power system (ROPS) forms the other subsystem. Damping torque analysis is applied to indicate that when an oscillation mode of VSG subsystem is in the proximity of an electromechanical oscillation mode of ROPS subsystem on the complex plane, strong dynamic interactions are introduced by the VSG to decrease the small-signal angular stability of the power system. This implies that when the parameters of the VSG are set, modal proximity of the VSG to the electromechanical oscillation mode of ROPS subsystem should be examined to avoid the detrimental impact of the VSG on power system small-signal angular stability. A method to evade the modal proximity is proposed in the paper for guiding the design of the VSG. An example power system with multiple VSGs for the wind power generation and transmission is presented. Study cases demonstrate and evaluate the analysis about the impact of modal proximity and proposed method for guiding the parameters setting of VSGs.
9 February 2015 in IEEE Transactions on Power Systems
This paper presents an improved corrective security constrained optimal power flow (CSCOPF) for a meshed AC/DC power transmission network with voltage source converter based multi-terminal HVDC (VSC-MTDC) grids. The security constrains of N-1 contingencies for both AC and DC networks are fully considered in the CSCOPF problem. The corrective actions employed in this paper include not only the traditional long-term rescheduling control actions of the AC system, but also the short term post-contingency fast corrective control of multi-terminal VSC-HVDC. A hybrid method is developed to solve the improved CSCOPF problem and the effectiveness of the proposed method is evaluated and demonstrated in this paper by two example meshed AC/DC power systems.