David Yc Huang

David Yc Huang

Auto-generated profile, based on publicly available information

David Yc Huang

Department of Medical Physics, Duke University, Durham, NC 27708, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JLJang-Chun Lin
Jang-Chun Lin
YWYi-Chieh Wu
Yi-Chieh Wu
FYFu-Chi Yang
Fu-Chi Yang
JTJO TING TSAI
JO TING TSAI
DHDavid Yc Huang
David Yc Huang
WLWei-Hsiu Liu
Wei-Hsiu Liu
Primary brain malignancy is a rare tumor with a global incidence of less than 10 per 100,000 people. Hence, there is limited power for identifying risk loci in individual studies, especially for Han Chinese. We performed a genome-wide association study (GWAS) in Taiwan, including 195 cases and 195 controls. We identified five new genes for malignant neoplasms of the brain: EDARADD (rs645507, 1p31.3, p = 7.71 × 10−5, odds ratio (OR) = 1.893), RBFOX1 (rs8044700, p = 2.35 × 10−5, OR = 2.36), LMF1 (rs3751667, p = 7.24 × 10−7, OR = 2.17), DPP6 (rs67433368, p = 8.32 × 10−5, OR = 3.94), and NDUFB9 (rs7827791, p = 9.73 × 10−6, OR = 4.42). These data support that genetic susceptibility toward GBM or non-GBM tumors is highly distinct, likely reflecting different etiologies. Combined with signaling analysis, we found that RNA modification may be related to major risk factors in primary malignant neoplasms of the brain.

25 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CKChun-Yuan Kuo
Chun-Yuan Kuo
WLWei-Hsiu Liu
Wei-Hsiu Liu
YCYu-Ching Chou
Yu-Ching Chou
MLMing-Hsien Li
Ming-Hsien Li
JTJO TING TSAI
JO TING TSAI
JLJang-Chun Lin
Jang-Chun Lin
Background: Radiotherapy (RT) provides a modern treatment to enhance the malignant glioma control rate. The purpose of our study was to determine the effect of tumor coverage on disease prognosis and to predict optimal RT plans to achieve a lower normal tissue complication probability (NTCP). Methods: Ten malignant-glioma patients with tumors adjacent to organs at risk (OARs) were collected. The patients were divided into two groups according to adequate coverage or not, and prognosis was analyzed. Then, using intensity-modulated radiation therapy (IMRT), volume-modulated arc therapy (VMAT), and helical tomotherapy (TOMO) to simulate new treatment plans for 10 patients, the advantages of these planning systems were revealed for subsequent prediction of NTCP. Results: The results of clinical analysis indicated that overall survival (p = 0.078) between the adequate and inadequate groups showed no differences, while the adequate group had better recurrence-free survival (p = 0.018) and progression-free survival (p = 0.009). TOMO had better CI (p < 0.001) and also predicted a lower total-irradiated dose to the normal brain (p = 0.001) and a lower NTCP (p = 0.027). Conclusions: The TOMO system provided optimal therapeutic planning, reducing NTCP and achieving better coverage. Combined with the clinical results, our findings suggest that TOMO can make malignant glioma patients close to OARs achieve better disease control.

3 January 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SHShih-Ming Hsu
Shih-Ming Hsu
CHChao-Hsiung Hung
Chao-Hsiung Hung
YLYi-Jen Liao
Yi-Jen Liao
HFHsiao-Mei Fu
Hsiao-Mei Fu
JTJo-Ting Tsai
Jo-Ting Tsai
DHDavid Y. C. Huang
David Y. C. Huang
CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotoluminescent glass dosimeter, thermoluminescent dosimeter, and Kodak EDR2 film were used to measure the lateral dose profile and percent depth dose of CyberKnife. A Monte Carlo simulation for dose verification was performed using BEAMnrc to verify the measured results. This study also used a radiophotoluminescent glass dosimeter coupled with an anthropomorphic phantom to evaluate the accuracy of the dose given by CyberKnife. Measurements from the radiophotoluminescent glass dosimeter were compared with the results of a thermoluminescent dosimeter and EDR2 film, and the differences found were less than 5%. The radiophotoluminescent glass dosimeter has some advantages in terms of dose measurements over CyberKnife, such as repeatability, stability, and small effective size. These advantages make radiophotoluminescent glass dosimeters a potential candidate dosimeter for the CyberKnife procedure. This study concludes that radiophotoluminescent glass dosimeters are a promising and reliable dosimeter for CyberKnife dose verification with clinically acceptable accuracy within 5%.